JDXNF2-35W(G)(L) 35 kV tashqi, moyli kuchlanish transformatori

JDXNF2-35W(G)(L) 35 kV tashqi, moyli kuchlanish transformatori

JDXNF2-35W(G)(L) — 35 kV tizimlari uchun yaxshilangan ifloslanishga chidamlilikka ega bo‘lgan tashqi o‘rnatishli moyli bir fazali kuchlanish transformatori.

  • Moyli izolyatsiya uzluksiz yuqori yuklama ostida ishlash uchun ajoyib issiqlik tarqatish imkonini beradi
  • Yuqori issiqlik sig‘imi (1000 VA chegaraviy quvvat) katta yuklama sharoitida ishonchli ishlashni ta’minlaydi
  • Qattiq iqlim sharoitlarida foydalanish uchun keng harorat oralig‘i (-40°C dan +40°C gacha)
  • Ko‘plab ikkilamchi chiqish konfiguratsiyalari (yon tomondan chiqish yoki 5/7 teshikli yuqori chiqish)
  • O‘rtacha va kuchli ifloslangan muhitlarda ishlatish uchun ifloslanishga chidamlilik darajalari W (II-daraja) va G (III-daraja)
  • Turli mamlakatlar, hududlar hamda loyiha talablari uchun sozlanishi mumkin

Mahsulotga umumiy ko’rib chiqish

JDXNF2-35W(G)(L) kuchlanish transformatori — bu 35 kV yuqori kuchlanishli elektr tarmoqlari uchun mo’ljallangan, ifloslanishga chidamli xususiyatga ega bo’lgan tashqi joyda ishlatiladigan moyli, bir fazali o’lchash qurilmasidir. Ushbu ilg’or kuchlanish transformatori moyli izolyatsiya tizimiga ega bo’lib, qattiq tashqi muhit sharoitlarida uzluksiz yuqori yuklama ostida ishlash uchun ajoyib issiqlik tarqatish imkonini beradi. JDXNF2-35W(G)(L) seriyasi turli o’rnatish talablari uchun moslashuvchan ikkilamchi chiqish variantlari (yon tomondan chiqish yoki yuqori tomondan 5/7 teshikli chiqish) bilan bir nechta konfiguratsiyalarni o’z ichiga oladi.

JDXNF2-35W(G)(L) turli konfiguratsiyalar orqali moslashuvchan kuchlanishni o’lchash yechimlarini taqdim etadi: asosiy kuchlanishni o’zgartirish uchun standart nisbat 35/√3 : 0.1/√3 : 0.1/3 V yoki yer xatosini aniqlash va neytral nuqtani kuzatish uchun qoldiq kuchlanish g’altakligi bilan kengaytirilgan nisbat 35/√3 : 0.1/√3 : 0.1/√3 : 0.1/3 V. Turli aniqlik sinflari (0.2, 0.5, 1.0, 3P) aniq o’lchashdan himoya talablarigacha bo’lgan barcha ehtiyojlarga javob beradi; issiqlik chegaraviy quvvati 1000 VA (standart) yoki 2×500 VA (ikkita qoldiq g’altaklik) bo’lib, og’ir yuklama sharoitlarida ishonchli ishlashni ta’minlaydi. Moyli konstruktsiya epoksidli quyish rezinli analoglarga qaraganda yaxshi issiqlik tarqatish imkonini beradi, to’liq yopiq dizayn esa moyning qarishini oldini oladi va xizmat muddatini uzaytiradi. Ifloslanishga chidamlilik darajalari W (II-daraja) va G (III-daraja) o’rta va kuchli ifloslangan muhitlarda ishonchli ishlashni ta’minlaydi. Keng ish harorati diapazoni (-40°C dan +40°C gacha) hamda GB20840.3-2013 va IEC61869-3:2011 standartlariga mos kelishi turli sohalarda ishonchli ishlashni kafolatlaydi.

Mahsulot namoyishi

JDXNF2-35W(G)(L) kuchlanish transformatori

JDXNF2-35W(G)(L) kuchlanish transformatorining qo'llanilishi
JDXNF2-35W(G)(L) kuchlanish transformatorini o'rnatish

Qo’llanish sohasi

JDXNF2-35W(G)(L) tashqi podstantsiyalarda, yuqori kuchlanishli kalit stansiyalarida va kuchlanishni ishonchli o’lchash, yaxshi issiqlik xususiyatlari hamda ifloslanishga chidamlilik talab qilinadigan uzatish tarmoqlarida o’rnatiladi. Moyli izolyatsiya tizimi uzluksiz yuqori yuklama ostida ishlash uchun ajoyib issiqlik tarqatish imkonini beradi, bu esa transformatorlar issiqlik chegarasiga yaqin ishlaydigan sohalarda foydalanish uchun idealdir. To’liq yopiq moyli idish konstruktsiyasi moyning qarishini oldini oladi va xizmat muddatini uzaytirib, texnik xizmat ko’rsatish ehtiyojini kamaytiradi. Ifloslanishga chidamlilik darajalari W (II-daraja) va G (III-daraja) o’rta va kuchli ifloslangan muhitlarda ishonchli ishlashni ta’minlaydi. Odatiy o’rnatish beton poydevorga mustahkamlash, to’g’ri yerlov hamda texnik xizmat ko’rsatish uchun yetarli bo’sh joy ajratishni o’z ichiga oladi. Moyli konstruktsiya qattiq tashqi sharoitlarga, jumladan ekstremal haroratlarga (-40°C dan +40°C gacha), namlikka va ifloslanishga chidamli.

Asosiy qo’llanish sohalari

  • Yuqori issiqlik quvvatini talab qiluvchi 35 kV tashqi podstantsiyalar
  • Yuqori kuchlanishli uzatish liniyasi kuchlanishini kuzatish
  • Uzluksiz og’ir yuklamali sanoat elektr taqsimlash tizimlari
  • Qayta tiklanadigan energiya podstantsiyalari (shamol fermerlik xo’jaliklari, quyosh elektr stansiyalari)
  • Tashqi taqsimlash bilan qishloq elektrlashtirish loyihalari
  • Yer xatosini aniqlashni talab qiluvchi kommunal tarmoqlar
  • O’rta va kuchli ifloslangan muhitlarda qo’llash (W/G darajalari)
  • 1000 VA issiqlik chegaraviy quvvatini talab qiluvchi og’ir yuklama sohalari
  • Ekstremal haroratli muhitlar (-40°C dan +40°C gacha)

Qo’llanish holatlari bo’yicha tadqiqotlar

Qo’llanish holati 1: Ekstremal haroratli tashqi podstantsiya
Kommunal xizmat korxonalari JDXNF2-35W(G)(L) moyli kuchlanish transformatorlarini 35 kV tashqi podstantsiyalarida, ekstremal harorat o’zgarishlari yaxshi issiqlik xususiyatlarini talab qiladigan joylarda ishlatadi. Moyli izolyatsiya tizimi ajoyib issiqlik tarqatish imkonini beradi, bu esa transformatorning -40°C dan +40°C gacha atrof-muhit haroratida ishonchli ishlashiga imkon beradi. 1000 VA issiqlik chegaraviy quvvati yuqori atrof-muhit haroratida ham og’ir yuklama sharoitlarida ishonchli ishlashni ta’minlaydi. To’liq yopiq moyli idish konstruktsiyasi moyning qarishini oldini oladi, xizmat muddatini uzaytiradi va ochiq konstruktsiyalarga qaraganda texnik xizmat ko’rsatish ehtiyojini kamaytiradi. Turli ikkilamchi chiqish konfiguratsiyalari (yon tomondan chiqish yoki yuqori tomondan 5/7 teshikli chiqish) turli podstantsiya sxemalari uchun o’rnatish moslashuvchanligini ta’minlaydi.

Qo’llanish holati 2: Sanoat tarmoqlarida yer xatosini aniqlash
35 kV taqsimlash tarmoqlari mavjud bo’lgan sanoat korxonalari uskunalar zararlanishini oldini olish va xodimlar xavfsizligini ta’minlash uchun ishonchli yer xatosini aniqlashni talab qiladi. Qoldiq kuchlanish g’altakligi (35/√3 : 0.1/√3 : 0.1/√3 : 0.1/3 V nisbati) bilan JDXNF2-35W(G)(L) modeli ochiq delta ikkilamchi g’altaklik konfiguratsiyasi orqali maxsus yer xatosini aniqlash imkonini beradi. Qoldiq kuchlanish g’altakligi yer xatosi paytida nol ketma-ketligidagi kuchlanishni aniqlaydi, bu esa himoya relelari xato bo’limlarni tezda ajratib, ketma-ketlikdagi nosozliklarni oldini olish imkonini beradi. Moyli izolyatsiya tizimi uzluksiz ishlash uchun yaxshi issiqlik xususiyatlarini ta’minlaydi, to’liq yopiq dizayn esa moyning qarishini oldini oladi va xizmat muddatini uzaytiradi. Ifloslanishga chidamlilik G darajasi (III-daraja) kuchli ifloslangan sanoat muhitlarida ishonchli ishlashni ta’minlaydi, 100 VA 3P aniqlik sinfi esa xato sharoitlarida ishonchli himoya xususiyatlarini ta’minlaydi.

Qo’llanish mosligi

Quyidagilar uchun mos

  • Tashqi 35 kV kuchlanishni o’lchash sohalari
  • Yuqori issiqlik quvvatini talab qilish (1000 VA chegaraviy quvvat)
  • Uzluksiz og’ir yuklama ostida ishlash
  • Yer xatosini aniqlash sohalari (qoldiq g’altaklik bilan)
  • O’rta va kuchli ifloslangan muhitlar (W/G darajalari)
  • Yaxshi issiqlik tarqatishni talab qiluvchi sohalar
  • Yuqori kuchlanishli uzatish va taqsimlash tarmoqlari
  • 35 kV taqsimlash tizimlari mavjud bo’lgan sanoat korxonalari
  • Ekstremal haroratli muhitlar (-40°C dan +40°C gacha)

Quyidagilar uchun tavsiya etilmaydi

  • Ichki o’rnatish sohalari (ichki foydalanish uchun mo’ljallangan modellardan foydalaning)
  • Oqimni o’lchash sohalari (buning o’rniga tok transformatoridan foydalaning)
  • 40,5 kV dan yuqori kuchlanishli tizimlar (yuqori kuchlanish sinfli modellardan foydalaning)
  • Texnik xizmat ko’rsatishsiz ishlashni talab qiluvchi sohalar (epoksidli quyish rezinli modellardan foydalaning)
  • Joy cheklangan o’rnatishlar (moyli transformatorlar kattaroq)
  • Kompakt dizaynni talab qiluvchi sohalar (epoksidli quyish rezinli modellardan foydalaning)

O’rnatish sharoitlari

  • O’rnatish joyi: Tashqi podstantsiyalar, kalit stansiyalari yoki uzatish tarmoqlari
  • Atrof-muhit harorati: -40°C dan +40°C gacha
  • Dengiz sathidan balandlik: ≤ 1000 m (standart), undan yuqori balandlik buyurtma asosida mavjud
  • Izolyatsiya: Moyli (yaxshi issiqlik tarqatish)
  • Chastota: 50 Hz yoki 60 Hz
  • Faza konfiguratsiyasi: Bir fazali (uch fazali tizimlar uchun uchta birlikdan foydalaning)
  • Ifloslanishga chidamlilik darajasi: W (II-daraja) yoki G (III-daraja)
  • Qopqoq: To’liq yopiq moyli idish (moyning qarishini oldini oladi)
  • Texnik xizmat ko’rsatish: Moy sifatini tekshirish va tirnoqni tekshirish muntazam ravishda talab qilinadi
  • Ikkilamchi chiqish: Yon tomondan chiqish yoki yuqori tomondan chiqish (5/7 teshik)

Texnik parametrlar

JDXNF2-35W(G)(L) seriyasi 35 kV tizimlari uchun tashqi joyda ishlatiladigan moyli, bir fazali kuchlanish transformatorlarini o’z ichiga oladi. Ish harorati -40°C dan +40°C gacha, GB20840.3-2013 va IEC61869-3:2011 standartlariga mos keladi.

Model Nominal kuchlanish nisbati
(kV)
Aniqlik sinfi
& Nominal quvvat (VA)
Issiqlik chegaraviy
quvvati (VA)
Izolyatsiya darajasi
(kV)
JDXNF2-35W(G)
(Standart)
35/√3 : 0.1/√3 : 0.1/3 0.2/3P: 50/100
0.5/3P: 100/100
1.0/3P: 150/100
1000 40.5/80/185
JDXNF2-35W(G)
(Qoldiq g’altaklik bilan)
35/√3 : 0.1/√3 : 0.1/√3 : 0.1/3 0.2/0.5/3P: 30/40/100 2×500 40.5/80/185
JDXNF2-35W(G)(L)
(Kengaytirilgan)
35/√3 : 0.1/√3 : 0.1/3 0.2/3P: 75/100
0.5/3P: 150/100
1.0/3P: 200/100
1000 40.5/80/185
JDXNF2-35W(G)(L)
(Kengaytirilgan qoldiq g’altaklik bilan)
35/√3 : 0.1/√3 : 0.1/√3 : 0.1/3 0.2/0.5/3P: 40/50/100 2×500 40.5/80/185

Eslatma 1: JDXNF2-35W(G) – hisob-kitob va himoya sohalari uchun standart kuchlanishni o’zgartirish.

Eslatma 2: Qoldiq g’altaklik bilan JDXNF2-35W(G) – yer xatosini aniqlash va neytral nuqtani kuzatish uchun qoldiq kuchlanish g’altakligini o’z ichiga oladi.

Eslatma 3: JDXNF2-35W(G)(L) – og’ir yuklama sohalari uchun yuqori nominal quvvatga ega kengaytirilgan konfiguratsiya.

Eslatma 4: Qoldiq g’altaklik bilan JDXNF2-35W(G)(L) – zaxiralangan yer xatosini aniqlash uchun ikkita qoldiq g’altaklikka ega kengaytirilgan konfiguratsiya.

Eslatma 5: Ifloslanishga chidamlilik darajalari: W (II-daraja) – o’rta ifloslanish uchun, G (III-daraja) – kuchli ifloslanish uchun.

Eslatma 6: Har bir transformator uchun nominal quvvat va unga mos keladigan aniqlik sinfi faqat bitta variant sifatida mavjud.

Eslatma 7: Agar foydalanuvchi ma’lumotlari yuqoridagi doiradan tashqariga chiqsa, ular ishlab chiqaruvchi va xaridor o’rtasidagi kelishuvga bog’liq bo’lishi mumkin.

O’rnatish

O’lchamlar bo’yicha ma’lumot

JDXNF2-35W(G)(L) kuchlanish transformatori o'lchov chizmasi 1
JDXNF2-35W(G)(L) kuchlanish transformatori o'lchov chizmasi 2
JDXNF2-35W(G)(L) kuchlanish transformatori o'lchov chizmasi 3

Umumiy o’lchamlar konfiguratsiya va ikkilamchi chiqish turiga qarab farq qiladi. Standart konfiguratsiya: Balandligi 1085±5 mm, Poydevor eni 408 mm, Idish eni 368 mm. Ikkilamchi chiqish variantlari: yon tomondan chiqish (standart) yoki yuqori tomondan chiqish (5 teshik yoki 7 teshik). Og’irligi: konfiguratsiyaga qarab taxminan 126–143 kg. Mahkamlash: poydevor plitasida 4×M12 mahkamlash boltlari. Bo’sh joy: texnik xizmat ko’rsatish va moy namunasi olish uchun transformator atrofida kamida 600 mm bo’sh joy. Yuqori terminallar: M16 tayoqchalari bilan yuqori kuchlanishli izolyatorlar. Ikkilamchi chiqish: kabel ulanishi uchun pastki terminal qutisi yoki yuqori terminal qutisi.

Sim tortish sxemasi

JDXNF2-35W(G)(L) kuchlanish transformatori sim tortish sxemasi

JDXNF2-35W(G)(L) turli sim tortish konfiguratsiyalarini qo’llab-quvvatlaydi: to’liq hisob-kitob va himoya uchun Y/Y/Δ ulanishi (to’rtta g’altaklik) yoki standart kuchlanishni o’zgartirish uchun Y/Δ ulanishi (uchta g’altaklik). Birlamchi terminallar A, N 35 kV tizimiga ulanadi. Ikkilamchi chiqishlar 1a1n, 2a2n, 3a3n hisob-kitob va himoya uchun, da/dn esa ochiq delta yer xatosini aniqlash uchun. O’rnatish paytida to’g’ri polarlik va fazalar ketma-ketligiga e’tibor bering.

O’rnatish yo’riqnomalari

  1. Poydevor: 126–143 kg og’irlikni ko’tara oladigan tekis beton poydevorga o’rnating. Poydevor suv to’planishini oldini olish va moy namunasi olishni osonlashtirish uchun yerdan 150 mm yuqorida bo’lishi kerak. M12 ankerni poydevorga kamida 200 mm chuqurlikka mahkamlab qo’ying.
  2. Yerlov: Yerlov terminalini (M10) kamida 50 mm² kesimli mis o’tkazgich yordamida podstantsiya yerlov tarmog’iga ulang. Yerlov qarshiligi 4 ommdan kam bo’lishi kerak. Transformator poydevorini va ikkilamchi g’altaklik neytral nuqtasini yerlang.
  3. Bo’sh joy: Texnik xizmat ko’rsatish, moy namunasi olish va ventilyatsiya uchun barcha tomonlarda kamida 600 mm bo’sh joy saqlang. Mahalliy elektr qoidalari bo’yicha tirik qismlardan yetarli masofa saqlang (odatda 35 kV uchun 400 mm).
  4. Birlamchi ulanish: Birlamchi terminallarni (A, N) mos keladigan yuqori kuchlanishli o’tkazgichlar yoki magistral shinalar yordamida 35 kV elektr tizimiga ulang. To’g’ri fazalar ketma-ketligi va moment spetsifikatsiyalariga (odatda M16 boltlar uchun 60 N·m) rioya qiling.
  5. Ikkilamchi ulanish: Ikkilamchi terminallarni sim tortish sxemasiga muvofiq hisob-kitob qurilmalari, himoya relelari yoki kuzatish uskunalari bilan ulang. Ikkinchi darajali zanjirlarda elektromagnit aralashuvni kamaytirish uchun ekranlangan kabeldan foydalaning. To’g’ri ulash va belgilashga e’tibor bering.
  6. Moy darajasini tekshirish: Quvvat berishdan oldin moy darajasini ko’rsatuvchi indikator orqali moy darajasi to’g’riligini tekshiring. Moy darajasi MIN va MAX belgilari orasida bo’lishi kerak. Agar moy darajasi past bo’lsa, moy to’ldirish jarayoni bo’yicha ishlab chiqaruvchiga murojaat qiling.
  7. Ishga tushirish testlari: Quvvat berishdan oldin izolyatsiya qarshiligini (20°C da kamida 1000 MΩ), burilish nisbatini, polarlikni va moy dielektrik mustahkamligini (kamida 30 kV/2,5 mm) tekshiring. Barcha ulanishlarning mahkam va to’g’ri momentda ekanligini tekshiring.

Moyli izolyatsiya xususiyatlari

  • Ajoyib issiqlik tarqatish: Moyli izolyatsiya ajoyib issiqlik tarqatish imkonini beradi, bu esa transformatorning harorat chegarasidan oshmasdan yuqori yuklama darajasida ishlashiga imkon beradi. Moy tabiiy aylanish orqali issiqlikni g’altaklik va o’ramlardan tashqi idish devorlariga uzatadi, u yerda atrof-muhit havo orqali tarqatiladi.
  • Yuqori issiqlik quvvati: Moyli dizayn yuqori issiqlik quvvatini (1000 VA issiqlik chegaraviy quvvati) ta’minlaydi, bu esa og’ir yuklama sharoitlarida uzluksiz ishlash imkonini beradi. Bu yuqori atrof-muhit haroratida transformatorlar issiqlik chegarasiga yaqin ishlaydigan sohalarda juda muhimdir.
  • To’liq yopiq konstruktsiya: To’liq yopiq moyli idish havo va namlik bilan aloqani kamaytirib, moyning qarishini oldini oladi. Bu moy xizmat muddatini uzaytiradi va ochiq konstruktsiyalarga qaraganda texnik xizmat ko’rsatish ehtiyojini kamaytiradi. Yopiq konstruktsiya chang va ifloslanuvchi moddalardan kirishni ham oldini oladi.
  • Ajoyib dielektrik mustahkamlik: Transformator moyi o’ramlar orasida hamda o’ramlardan yerga qarab ishonchli izolyatsiya ta’minlaydigan ajoyib dielektrik mustahkamlikka ega. Moy izolyatsiya tizimidagi barcha bo’shliqlar va teshiklarni to’ldirib, elektr maydonni tekis taqsimlaydi va qisman razryadlarni oldini oladi.
  • Sinovdan o’tgan texnologiya: Moyli transformatorlar yuqori kuchlanishli sohalarda bir asrdan ko’proq vaqt davomida ishlatilib kelinmoqda, bu esa ishonchlilik va ishlash bo’yicha sinovdan o’tgan rekordni ta’minlaydi. Texnologiya yaxshi o’rganilgan va texnik xizmat ko’rsatish tartiblari standartlashtirilgan.

Standartlar

  • GB20840.3-2013 (O’lchov transformatorlari – 3-qism: Induktiv kuchlanish transformatorlari)
  • IEC61869-3:2011 (O’lchov transformatorlari – 3-qism: Induktiv kuchlanish transformatorlari)
  • Xaridorning maxsus talablari buyurtma asosida mavjud

Tanlash bo’yicha yo’riqnoma

JDXNF2-35W(G)(L) kuchlanish transformatorini tanlashda quyidagi omillarni hisobga oling:

  • Modelni tanlash: Standart kuchlanishni o’lchash uchun JDXNF2-35W(G) yoki kengaytirilgan nominal quvvat uchun JDXNF2-35W(G)(L) ni tanlang. Agar yer xatosini aniqlash talab qilinsa, qoldiq kuchlanish g’altakligi mavjud modelni tanlang
  • Aniqlik sinfi: Daromad hisob-kitobi uchun 0.2, kuzatish sohalari uchun 0.5, umumiy o’lchash uchun 1.0, himoya sohalari uchun 3P ni tanlang
  • Yuklama talablari: Nominal quvvat ulangan yukka (hisob-kitob qurilmalari, relelar) mos kelishini ta’minlang, shunda aniqlik saqlanadi. Issiqlik chegaraviy quvvati standart modellar uchun 1000 VA yoki qoldiq g’altaklikli modellar uchun 2×500 VA
  • Atrof-muhit sharoitlari: Atrof-muhit harorati (-40°C dan +40°C gacha), dengiz sathidan balandlik (≤1000 m standart) va ifloslanishga chidamlilik darajasi (o’rta ifloslanish uchun W, kuchli ifloslanish uchun G) o’rnatish muhitiga mos kelishini tekshiring
  • Ikkilamchi chiqish konfiguratsiyasi: O’rnatish talablari va kabel yo’naltirishiga qarab yon tomondan chiqish (standart) yoki yuqori tomondan chiqish (5/7 teshik) ni tanlang
  • <

Inquiry for JDXNF2-35W(G)(L) 35 kV tashqi, moyli kuchlanish transformatori:

Send your project requirements. Our team will reply with technical details and quotation.

Fast response Technical support OEM / ODM