JSZJK-3/6/10R Sug’orilgan uch fazali ferrorezonansga qarshi kuchlanish transformatori

JSZJK-3/6/10R Sug’orilgan uch fazali ferrorezonansga qarshi kuchlanish transformatori

JSZJK ichki, uch fazali ferrorezonansga qarshi sig'imli kuchlanish transformatori, kuchlanish nazorati va rele himoyasi bilan.

  • Sig'imli uch fazali ferrorezonansga qarshi kuchlanish transformatori
  • O'rta kuchlanishli kommutatsion apparatlar uchun ichki epoksidli quyilgan izolyatsiya
  • 3 kV, 6 kV va 10 kV tizimlari uchun mos
  • Xalqaro kuchlanish sinflari: 3,6 kV, 7,2 kV va 12 kV
  • Hisoblash, himoya va qoldiq kuchlanishni kuzatish zanjirlarini qo'llab-quvvatlaydi
  • Bitta yoki ikkita sekundar chulg'amli variantlarda mavjud

Mahsulotga umumiy ko’rib chiqish

JSZJK-3/6/10R — o’rta kuchlanishli kommutatsion apparatlar uchun epoksidli quyilgan izolyatsiyali, ichki o’rnatish uchun mo’ljallangan uch fazali ferrorezonansga qarshi sig’imli kuchlanish transformatoridir. U 50 Hz / 60 Hz elektr tarmoqlari uchun mo’ljallangan bo’lib, kuchlanishni o’lchash, energiya hisobini yuritish, kuchlanishni kuzatish, qoldiq kuchlanishni aniqlash va releli himoya maqsadlarida ishlatiladi.

Ushbu model JDZ8 yoki JDZ10 kabi oddiy bir fazali sig’imli VTlardan farq qiladi. JSZJK-3/6/10R — uch fazali integratsiyalangan ferrorezonansga qarshi VT bo’lib, unda kattaroq korpus, himoya sxemalarida ferrorezonansga qarshi va qoldiq kuchlanish funksiyalarini talab qiluvchi ko’plab ikkilamchi konfiguratsiyalar hamda ulash sxemalari mavjud.

Mahsulot namoyishi

JSZJK-3/6/10R Sig'imli Uch Fazali Ferrorezonansga Qarshi Kuchlanish Transformatori Mahsulot Namoyishi

Qo’llash sohasi

JSZJK-3/6/10R transformatori odatda ichki o’rnatish uchun mo’ljallangan o’rta kuchlanishli kommutatsion apparatlar yoki kuchlanish transformatorlari uchun ajratilgan xonalarga o’rnatiladi. U hisoblagichlar, relelar va kuzatuv qurilmalariga ikkilamchi kuchlanish beradi, shuningdek, uning ferrorezonansga qarshi tuzilishi ferrorezonans xavfini boshqarish zarur bo’lgan o’rta kuchlanishli tarmoqlarda tizim barqarorligini yaxshilashga yordam beradi.

Asosiy qo’llash sohalari

  • Ichki o’rnatish uchun mo’ljallangan 3 kV, 6 kV va 10 kV o’rta kuchlanishli kommutatsion apparatlar
  • 3,6 kV, 7,2 kV va 12 kV sinfli elektr taqsimlash tizimlari
  • Kuchlanishni o’lchash va energiya hisobini yuritish zanjirlari
  • Releli himoyaning kuchlanish kirish zanjirlari
  • Qoldiq kuchlanishni kuzatish va izolyatsiya nazorati zanjirlari
  • Ferrorezonansga qarshi va qoldiq kuchlanish funksiyalarini talab qiluvchi kommutatsion apparatlarda uch fazali integratsiyalangan ferrorezonansga qarshi VT kerak bo’lganda

Asosiy texnik xususiyatlar

Parametr Xususiyat
Model seriyasi JSZJK-3R / JSZJK-6R / JSZJK-10R
Mahsulot turi Ichki o’rnatish uchun mo’ljallangan uch fazali ferrorezonansga qarshi kuchlanish transformatori / potentsial transformatori
Izolyatsiya tuzilishi Ichki o’rnatish uchun epoksidli quyilgan izolyatsiya
Birlamchi himoya Sig’im bilan
O’rnatish Ichki kommutatsion apparatlarga o’rnatish
Tizim kuchlanishi 3 kV, 6 kV va 10 kV tizimlar
Xalqaro kuchlanish sinfi 3,6 kV, 7,2 kV va 12 kV sinflari
Nominal chastota 50 Hz / 60 Hz
Atrof-muhit harorati -25°C dan +40°C gacha
Odatiy ulash sxemasi Qoldiq kuchlanish chiqishi variantlari bilan bitta yoki ikkita ikkilamchi chulg’am konfiguratsiyalari
Odatiy vazifasi Hisob-kitob, kuchlanishni kuzatish, releli himoya va ferrorezonansga qarshi ishlash
Taxminiy og’irligi 102 kg
Standartlar GB20840.3-2013, IEC61869-3:2011 hamda loyihaga xos talablarni qondiradi

Qo’llash mosligi

Quyidagilar uchun mos:

  • Uch fazali integratsiyalangan VT tuzilishini talab qiluvchi ichki kommutatsion apparatlar
  • Ferrorezonansni bostirish muhim ahamiyatga ega bo’lgan o’rta kuchlanishli tizimlar
  • Qoldiq kuchlanishni kuzatish yoki himoyaga oid ikkilamchi chiqishni talab qiluvchi loyihalar
  • 3 kV, 6 kV va 10 kV tizimlarida hisob-kitob va releli himoya dasturlari
  • Uchta alohida bir fazali VT o’rniga bitta integratsiyalangan uch fazali qurilmani afzal ko’radigan kommutatsion apparat ishlab chiqaruvchilari

Quyidagilar uchun tavsiya etilmaydi:

  • Himoya qopqog’isiz tashqi joylarda o’rnatish
  • 102 kg lik integratsiyalangan VT korpusini joylashtirish imkoniyati bo’lmagan ixcham kommutatsion apparatlar
  • Faqat oddiy bir fazali hisob-kitob VT kerak bo’lgan dasturlar
  • Yuqori chastotali elektron transformator dasturlari
  • Moyli kuchlanish transformatorlari dasturlari
  • Texnik tasdiqlashsiz standart bo’lmagan chiqish kombinatsiyalarini talab qiluvchi loyihalar

O’rnatish sharoiti

  • O’rnatish joyi: ichki kommutatsion apparatlar yoki himoyalangan ichki elektr shkafi
  • Nominal chastota: 50 Hz / 60 Hz sanoat chastotali o’zgaruvchan tok tizimi
  • Atrof-muhit harorati: -25°C dan +40°C gacha
  • O’rnatish maydoni: shkafni tasdiqlashdan oldin eni, chuqurligi, balandligi va 102 kg og’irligini tekshiring
  • Elektr oraliq masofasi: fazalararo va fazadan yergacha bo’lgan oraliq masofani kommutatsion apparat loyihasiga muvofiq tekshiring
  • Ta’mirlash: muntazam tekshiruv paytida sig’im holati, ikkilamchi terminaldagi mahkamlash va rezina sirt holatini tekshiring

Texnik tuzilma

JSZJK-3/6/10R seriyasi uch fazali kuchlanish transformatsiyasini va ferrorezonansga qarshi dizaynni bitta integratsiyalangan epoksidli quyilgan korpusda birlashtiradi. Mahsulot alohida bir fazali transformatorlarni yig’ish o’rniga bitta uch fazali VT yechimini talab qiluvchi muhandislar uchun mos keladi.

Komponent Tavsif
Uch fazali magnit tuzilma Hisob-kitob va himoya zanjirlari uchun integratsiyalangan uch fazali transformator tuzilmasi
Ferrorezonansga qarshi dizayn O’rta kuchlanishli tizimlarda ferrorezonans xavfini kamaytirish uchun mo’ljallangan
Birlamchi sig’im Tanlangan konfiguratsiyaga muvofiq birlamchi tomonni himoya qiladi
Epoksidli quyilgan korpus Ichki izolyatsiya, mexanik qo’llab-quvvatlash va namlikka chidamlilikni ta’minlaydi
Ikkilamchi chulg’am Hisob-kitob, himoya va qoldiq kuchlanish chiqish kombinatsiyalari bilan mavjud
Terminal qismi Hisob-kitob va himoya ulashlari uchun ko’plab ikkilamchi terminallar joylashtirilgan
O’rnatish poydevori Barqaror kommutatsion apparatga o’rnatish uchun katta poydevor tuzilmasi

Model belgilash

JSZJK 3 6 10R Fused Three Phase Anti Ferroresonance Voltage Transformer modle type

  • J = Kuchlanish transformatori
  • S = Uch fazali tuzilma
  • Z = Epoksidli quyilgan izolyatsiya
  • J = Ferrorezonansga qarshi / maxsus dizayn seriya kodi
  • K = Tuzilma yoki dizayn kodi, yakuniy chizmaga bog’liq
  • 3 / 6 / 10 = 3 kV, 6 kV yoki 10 kV dasturlari uchun nominal tizim kuchlanish kodi
  • R = Sig’im bilan

Texnik ma’lumotlar

Quyidagi ma’lumotlar JSZJK-3/6/10R mahsulot namunasidan olingan. Xalqaro mahsulot sahifalari uchun ichki 3 kV / 6 kV / 10 kV tizim reytinglari 3,6 kV / 7,2 kV / 12 kV izolyatsiya sinflari bilan moslashtirilishi kerak.

Model Nominal

Kuchlanish

Nisbati

Aniqlik sinfi /

Nominal quvvat

Chegaraviy

quvvat

Nominal

izolyatsiya

darajasi

JSZJK-3R 3000/√3 / 100/√3 / 100 0.2/6P(3P)—45/100
0.5/6P(3P)—100/100
1/6P(3P)—150/100
600 VA 3,6/25/40 kV
JSZJK-6R 6000/√3 / 100/√3 / 100 7,2/30/60 kV
JSZJK-10R 10000/√3 / 100/√3 / 100 12/42/75 kV
JSZJK-6R 6000/√3 / 100/√3 / 100/√3 / 100 0.2/0.2/6P(3P)—30/30/100
0.2/0.5/6P(3P)—30/50/100
0.5/0.5/6P(3P)—50/50/100
500 VA 7,2/30/60 kV
JSZJK-10R 10000/√3 / 100/√3 / 100/√3 / 100 0.2/0.2/6P(3P)—30/30/100
0.2/0.5/6P(3P)—30/50/100
0.5/0.5/6P(3P)—50/50/100
500 VA 12/42/75 kV
JSZJK-6R 6000/√3 / 100/√3 / 220/√3 / 100 0.2/3/6P(3P)—30/500/100
0.5/3/6P(3P)—50/500/100
600 VA 7,2/30/60 kV
JSZJK-10R 10000/√3 / 100/√3 / 220/√3 / 100 0.2/3/6P(3P)—30/500/100
0.5/3/6P(3P)—50/500/100
600 VA 12/42/75 kV

Texnik eslatmalar:

  • Bitta transformator bitta tanlangan aniqlik sinfi va nominal quvvat kombinatsiyasi bilan yetkazib beriladi.
  • 100/√3 chiqishi odatda hisob-kitob yoki kuchlanishni kuzatish uchun ishlatiladi.
  • Yordamchi quvvat yoki maxsus ikkilamchi chiqish kerak bo’lganda 220/√3 chiqishi tanlanishi mumkin.
  • 100 V qoldiq yoki ochiq delta chiqishi loyiha dizayniga muvofiq himoyaga oid kuzatuv uchun ishlatilishi mumkin.
  • Talab qilingan parametrlar ko’rsatilgan diapazondan tashqarida bo’lsa, ishlab chiqaruvchi va xaridor o’rtasida tasdiqlash talab qilinadi.

O’rnatish va o’lchamlar

JSZJK-3/6/10R Sig'imli Uch Fazali Ferrorezonansga Qarshi Kuchlanish Transformatori O'rnatish va O'lchamlar

O’lchamlar haqida ma’lumot

Parametr Ma’lumot qiymati
Umumiy uzunligi 490 mm (ma’lumot sifatida)
Poydevor uzunligi 455 mm (ma’lumot sifatida)
Yon tomon uzunligi 430 mm
Korpus uzunligi 370 mm
Umumiy eni 425 mm (ma’lumot sifatida)
Korpus eni 190 mm
Umumiy balandligi Taxminan 298 mm (ma’lumot sifatida)
Birlamchi terminallar orasidagi masofa 210 mm + 210 mm (ma’lumot sifatida)
Taxminiy og’irligi 102 kg

Terminal va ulash

JSZJK-3/6/10R Sig'imli Uch Fazali Ferrorezonansga Qarshi Kuchlanish Transformatori Terminal Belgilari

  • Birlamchi terminallar A, B va C fazalari uchun joylashtirilgan.
  • Ikkilamchi terminallar konfiguratsiyaga qarab 1a, 1b, 1c, 2a, 2b, 2c va da terminallarini o’z ichiga oladi.
  • Namuna chizmasi bitta va ikkita ikkilamchi chulg’am sxemalarini ko’rsatadi.
  • Qoldiq kuchlanish himoyasi uchun ulashdan oldin ochiq delta / da terminal konfiguratsiyasini tasdiqlang.
  • Ishga tushirishdan oldin terminallarning polarligi, yerga ulanishi va sig’im holatini tekshiring.

Standartlarga moslik va sinovlar

Mahsulot ma’lumotlari GB20840.3-2013 va IEC61869-3:2011 standartlariga asoslangan. Qo’shimcha namuna ma’lumotlari shuningdek GB1207 va IEC60044-2 standartlariga ham havola qiladi. Eksport loyihalari uchun yakuniy moslik bayoni texnik kelishuv va xaridor talablariga amal qilishi kerak.

Odatiy rutin sinovlar

  • Ko’z bilan ko’rish va nom plakatini tekshirish
  • Nisbatni tekshirish
  • Polyarlik va terminal belgilashni tekshirish
  • Belgilangan nominal yuklama ostida aniqlikni sinash
  • Sanoat chastotasida kuchlanishga chidamlilik sinovi
  • Kerak bo’lganda induktsion kuchlanishga chidamlilik sinovi
  • Izolyatsiya qarshiligini sinash
  • Sig’im va birlamchi zanjirni tekshirish
  • Agar yetkazib berilsa, qoldiq kuchlanish chulg’amini tekshirish

Muhandislik eslatmalari

  • 3 kV tizimlar uchun JSZJK-3R, 6 kV tizimlar uchun JSZJK-6R va 10 kV tizimlar uchun JSZJK-10R dan foydalaning.
  • Xalqaro sahifalar uchun modellarni izolyatsiya darajasiga muvofiq 3,6 kV, 7,2 kV va 12 kV sinfli mahsulotlar sifatida yozing.
  • Faqat asosiy kuchlanishni o’lchash emas, balki ferrorezonansga qarshi ishlash kerak bo’lganda ushbu seriyani tanlang.
  • Loyiha bitta ikkilamchi chulg’am, ikkita ikkilamchi chulg’am yoki qoldiq kuchlanish chiqishini talab qilishini aniqlang.
  • Taxminan 102 kg og’irlik kommutatsion apparat maketini loyihalashda ehtimoyat bilan tekshirilishi kerak.
  • Ushbu mahsulotni yuqori chastotali transformator sifatida tasvirlamang; bu 50 Hz / 60 Hz sanoat chastotali VT/PT dir.

Tanlov bo’yicha qo’llanma

Ferrorezonans talabiga ko’ra tanlang: Agar kommutatsion apparat loyihasi oddiy bir fazali sig’imli kuchlanish transformatori o’rniga uch fazali ferrorezonansga qarshi VT ni talab qilsa, JSZJK-3/6/10R ni tanlang.

Kuchlanish sinfiga ko’ra tanlang: 3 kV tizimlar uchun JSZJK-3R, 6 kV tizimlar uchun JSZJK-6R va 10 kV tizimlar uchun JSZJK-10R dan foydalaning. Xalqaro texnik shartnomalar uchun ularni 3,6 kV, 7,2 kV va 12 kV sinflari sifatida ifodalang.

Ikkilamchi konfiguratsiyaga ko’ra tanlang: Hisob-kitob va himoya uchun asosiy 100/√3 va 100 chiqishlardan foydalaning. Yordamchi chiqish yoki ajratilgan zanjirlar kerak bo’lganda ikkita ikkilamchi yoki 220/√3 chiqishli versiyalarni tanlang.

Himoya sxemasiga ko’ra tanlang: Agar tizim qoldiq kuchlanishni aniqlash, izolyatsiya nazorati yoki ochiq delta chiqishini talab qilsa, ishlab chiqarishdan oldin da terminali va qoldiq chulg’am sxemasini tasdiqlang.

Shkaf maketiga ko’ra tanlang: Kommutatsion apparat loyihasini tasdiqlashdan oldin 102 kg og’irlik, 490 mm umumiy uzunlik, terminallar orasidagi masofa va ikkilamchi terminalga kirish imkoniyatini tekshiring.

Tez-tez beriladigan savollar

U ichki o’rnatish uchun mo’ljallangan 3 kV, 6 kV va 10 kV o’rta kuchlanishli kommutatsion apparatlarda kuchlanishni o’lchash, energiya hisobini yuritish, releli himoya va qoldiq kuchlanishni kuzatish uchun ishlatiladi.

JDZ8 va JDZ10 asosan bir fazali sig’imli VTlardir. JSZJK esa ferrorezonansga qarshi va qoldiq kuchlanish funksiyalarini talab qiluvchi dasturlar uchun mos keladigan uch fazali integratsiyalangan ferrorezonansga qarshi kuchlanish transformatoridir.

Ha. R qo’shimchasi mahsulot sig’im himoyasi bilan yetkazib berilishini bildiradi.

Seriyaga 3 kV, 6 kV va 10 kV tizimlari kiradi. Xalqaro mahsulot sahifalari uchun ular 3,6 kV, 7,2 kV va 12 kV sinflari sifatida ifodalanishi kerak.

Ha. Tanlangan konfiguratsiyalar himoya va kuzatuv funksiyalari uchun qoldiq kuchlanish yoki ochiq delta chiqishini o’z ichiga oladi. Buyurtma berishdan oldin terminal sxemasini tasdiqlang.

Bu kommutatsion apparatlarga o’rnatish uchun mo’ljallangan ichki epoksidli quyilgan kuchlanish transformatoridir.

Inquiry for JSZJK-3/6/10R Sug’orilgan uch fazali ferrorezonansga qarshi kuchlanish transformatori:

Send your project requirements. Our team will reply with technical details and quotation.

Fast response Technical support OEM / ODM