Product Overview
The JDZ16-35R voltage transformer is an indoor epoxy resin cast single-phase measurement device designed for 35kV medium-voltage distribution systems. This advanced voltage transformer features epoxy resin cast insulation technology, providing excellent dielectric strength and maintenance-free operation for reliable performance in indoor environments.
The JDZ16-35R delivers precise voltage measurement for energy metering, voltage monitoring, and relay protection applications with multiple voltage ratios (35/0.1kV, 35/0.1/0.1kV, 35/0.1/0.22kV) and flexible accuracy classes (0.2, 0.5). The epoxy resin cast construction ensures superior insulation performance while providing up to 1000VA maximum output capacity. Compact design with 97kg weight simplifies installation and reduces structural support requirements.
Product Display



Application Position
The JDZ16-35R is installed in indoor switchgear, substations, and distribution networks where reliable single-phase voltage measurement is required. The epoxy resin insulation provides excellent moisture resistance and UV protection for long-term indoor operation. Multiple voltage ratios accommodate various measurement and protection system requirements.
Main Applications
- 35kV indoor distribution networks
- Substations requiring voltage measurement
- Industrial facilities with medium-voltage supply
- Energy metering applications
- Voltage monitoring and relay protection
- Indoor power distribution systems
Application Case Studies
Application Scenario 1: Substation Voltage Measurement
Utilities deploy the JDZ16-35R epoxy resin voltage transformer in 35kV indoor substations for energy metering and relay protection. The 35/0.1kV voltage ratio provides accurate voltage signals for protection relays, while the epoxy resin insulation ensures reliable performance in indoor environments with 40.5/95/200kV insulation level and maintenance-free operation.
Application Scenario 2: Industrial Medium-Voltage Metering
Industrial facilities with 35kV incoming supply require accurate voltage measurement for energy management and protection coordination. The JDZ16-35R offers multiple accuracy classes (0.2, 0.5) and voltage ratios (35/0.1kV, 35/0.1/0.1kV, 35/0.1/0.22kV) to meet different measurement requirements, with up to 1000VA maximum output capacity for various burden conditions.
Application Fit
Suitable For
- Indoor 35kV voltage measurement
- Substations with energy metering requirements
- Industrial facilities with medium-voltage supply
- Voltage monitoring applications
- Relay protection systems
- Environments requiring maintenance-free operation
Not Recommended For
- Outdoor installation applications (use outdoor-rated models)
- Current measurement applications (use CT instead)
- High-voltage systems above 40.5kV (use higher voltage class models)
- Applications requiring three-phase measurement in single unit
Installation Conditions
- Installation position: Indoor switchgear, substations, or distribution points
- Ambient temperature: -25°C to +40°C
- Altitude: ≤ 1000m (standard), higher altitude available on request
- Insulation: Epoxy resin cast
- Frequency: 50Hz or 60Hz
- Connection: Single-phase
- Maintenance: Minimal maintenance required (epoxy resin design)
Technical Parameters
The JDZ16-35R is an indoor epoxy resin cast single-phase voltage transformer for 35kV systems. Operating temperature -25°C to +40°C, compliant with GB20840.3-2013 and IEC61869-3:2011 standards.
VT Data – Single Secondary Winding
| Rated Voltage (kV) |
Accuracy Class & Rated Output (VA) |
Max Output (VA) |
Insulation Level (kV) |
|---|---|---|---|
| 35/0.1 | 0.2: 40 0.5: 100 |
600 | 40.5/95/200 |
VT Data – Dual Secondary Winding
| Rated Voltage (kV) |
Accuracy Class & Rated Output (VA) |
Max Output (VA) |
Insulation Level (kV) |
|---|---|---|---|
| 35/0.1/0.1 | 0.2/0.5: 30/50 0.2/0.2: 20/20 |
500 | 40.5/95/200 |
VT Data – Secondary with Power Supply
| Rated Voltage (kV) |
Accuracy Class & Rated Output (VA) |
Max Output (VA) |
Insulation Level (kV) |
|---|---|---|---|
| 35/0.1/0.22 | 0.2/3: 40/500 | 1000 | 40.5/95/200 |
Installation
Dimension Reference

| View | Key Dimensions |
Application Note |
|---|---|---|
| Side View | Width 481mm; Height 370mm; Base 502mm | Terminal M31×1.5 on left side |
| Front View | Width 341mm; Mounting holes 265mm; Height 408mm; Base 275mm | Terminals A and B, nameplate, M10 lifting ring |
| Top View | Length 602mm; Width 240mm | Terminal box connections |
Weight: Approximately 97kg
Wiring Diagram

Installation Guidelines
- Install in indoor switchgear or substation with adequate ventilation
- Connect primary terminals A and B to voltage system
- Connect secondary terminals to meters and protection devices
- Ensure proper grounding of secondary circuit
- Verify voltage ratio matches system requirements before commissioning
- Check insulation resistance before energizing
Epoxy Resin Features
The JDZ16-35R incorporates advanced epoxy resin technology including:
- Excellent moisture resistance for indoor operation
- UV protection for long-term performance
- Superior insulation performance with 40.5/95/200kV level
- Maintenance-free construction eliminating periodic inspection
Standards
The JDZ16-35R epoxy resin voltage transformer complies with GB20840.3-2013 and IEC61869-3:2011 for voltage transformers, ensuring compatibility with Chinese and international standards for medium-voltage measurement applications.
Selection Guide
Select by system voltage: JDZ16-35R is designed for 35kV systems with 40.5/95/200kV insulation level.
Select by voltage ratio: Choose 35/0.1kV for basic measurement, 35/0.1/0.1kV for dual secondary outputs, or 35/0.1/0.22kV for measurement with power supply.
Select by accuracy class: Use 0.2 for high-precision metering or 0.5 for standard metering.
Select by rated output: Choose rated output (20-500VA) based on connected burden requirements.
Ordering Information
When ordering the JDZ16-35R epoxy resin voltage transformer, please specify:
- Model: JDZ16-35R
- System voltage: 35kV
- Voltage ratio: 35/0.1kV, 35/0.1/0.1kV, or 35/0.1/0.22kV
- Accuracy class: 0.2 or 0.5
- Rated output: Specify VA value from table
- Frequency: 50Hz or 60Hz
- Installation type: Indoor
- Quantity
FAQs