Product Overview
The JDZX9-35G/210 voltage transformer is an indoor epoxy cast-resin single-phase measurement device designed for 35kV medium-voltage distribution systems. This advanced voltage transformer features epoxy resin cast insulation technology, providing excellent dielectric strength and maintenance-free operation for reliable performance in indoor environments.
The JDZX9-35G/210 delivers precise voltage measurement for energy metering, voltage monitoring, and relay protection applications with multiple accuracy classes (0.2, 0.5, 1.0) and Y/△ winding configuration. The epoxy resin cast construction ensures superior insulation performance with 40.5/80/185kV insulation level while providing up to 600VA thermal limit output capacity. Compact design with 42.15kg weight simplifies installation and reduces structural support requirements.
Product Display



The JDZX9-35G/210 indoor epoxy cast-resin voltage transformer features a compact design with tiered insulator structure for enhanced creepage distance. The dark brown epoxy resin housing provides excellent insulation performance with 40.5/80/185kV rated insulation level. The unit includes a clear terminal box for secondary connections and a metal base plate for secure mounting.
Application Position
The JDZX9-35G/210 is installed in indoor switchgear, substations, and distribution networks where reliable single-phase voltage measurement is required. The epoxy resin insulation provides excellent moisture resistance and long-term durability for indoor operation. Three units are typically connected in three-phase configuration with star-connected primary and secondary windings, plus open-delta connected residual voltage winding for ground fault detection.
Main Applications
- 35kV indoor distribution networks
- Substations requiring voltage measurement with ground fault detection
- Industrial facilities with medium-voltage supply
- Energy metering applications
- Voltage monitoring and relay protection
- Indoor power distribution systems
Application Case Studies
Application Scenario 1: Substation Voltage Measurement with Ground Fault Detection
Utilities deploy three JDZX9-35G/210 epoxy cast-resin voltage transformers in 35kV indoor substations for energy metering and ground fault protection. The three-winding configuration with Y/△ connection provides accurate voltage signals for protection relays and metering devices, while the open-delta connected residual voltage winding enables reliable ground fault detection. The epoxy resin insulation ensures reliable performance in indoor environments with 40.5/80/185kV insulation level and maintenance-free operation.
Application Scenario 2: Industrial Medium-Voltage Metering
Industrial facilities with 35kV incoming supply require accurate voltage measurement for energy management and protection coordination. The JDZX9-35G/210 offers multiple accuracy classes (0.2, 0.5, 1.0) to meet different measurement requirements, with 600VA thermal limit output capacity for various burden conditions. The compact 42.15kg design simplifies installation in space-constrained switchgear panels.
Application Fit
Suitable For
- Indoor 35kV voltage measurement
- Substations with ground fault detection requirements
- Industrial facilities with medium-voltage supply
- Voltage monitoring applications
- Relay protection systems
- Environments requiring maintenance-free operation
Not Recommended For
- Outdoor installation applications (use outdoor-rated models)
- Current measurement applications (use CT instead)
- High-voltage systems above 40.5kV (use higher voltage class models)
- Applications requiring three-phase measurement in single unit
Installation Conditions
- Installation position: Indoor switchgear, substations, or distribution points
- Ambient temperature: -5°C to +40°C
- Altitude: ≤ 1000m (standard), higher altitude available on request
- Insulation: Epoxy resin cast
- Frequency: 50Hz or 60Hz
- Connection: Single-phase (three units for three-phase system)
- Maintenance: Minimal maintenance required (epoxy resin design)
Technical Parameters
The JDZX9-35G/210 series includes indoor epoxy cast-resin single-phase voltage transformers for 35kV systems. Operating temperature -5°C to +40°C, compliant with GB1207-2006 and IEC60044-2:2003 standards.
| Rated Voltage (kV) |
Accuracy Class & Rated Output (VA) |
Thermal Limit Output (VA) |
Insulation Level (kV) |
|---|---|---|---|
| 35/√3 : 0.1/√3 : 0.1/3 | 0.2/3(6)P: 30/100 0.5/3(6)P: 60/100 1.0/3(6)P: 100/100 |
600 | 40.5/80/185 |
| 35/√3 : 0.1/√3 : 0.1/3 : 0.1/√3 : 0.1/3 | 0.2/0.5/3(6)P: 15/20/100 0.5/0.5/3(6)P: 30/30/100 |
Note 1: Three-winding configuration (35/√3 : 0.1/√3 : 0.1/3) – Standard Y/△ connection for basic metering and protection applications.
Note 2: Five-winding configuration (35/√3 : 0.1/√3 : 0.1/3 : 0.1/√3 : 0.1/3) – Enhanced configuration with dual secondary outputs for maximum flexibility and redundancy.
Note 3: Rated output and its relative accuracy class only one alternative per transformer.
Note 4: If user’s data go beyond the above-mentioned scopes, they may be subject to an agreement between manufacturer and purchaser.
Installation

Overall dimensions: Top width 320mm, base width 420mm, height 300mm. Creepage distance: 710mm. Weight: approximately 42.15kg. Mounting holes: M6, M10 on base plate. Ground terminal: M8.
Dimension Reference
Overall dimensions: Top width 320mm, base width 420mm, height 300mm. Creepage distance: 710mm. Weight: approximately 42.15kg. Mounting holes: M6, M10 on base plate. Ground terminal: M8. See Installation section for detailed dimension drawing.
Overall dimensions: 320mm (top width) × 420mm (base width) × 300mm (height). Creepage distance: 710mm. Weight: approximately 42.15kg. Mounting holes: M6, M10 on base plate.
Wiring Diagram

Y/△ Connection (Three-Winding) – Primary terminals A, B, C connect to star configuration, secondary outputs a, b, c for metering, da/dn for open-delta ground fault detection.
Y/△ Connection (Three-Winding) – Primary terminals A, B, C connect to star configuration, secondary outputs a, b, c for metering, da/dn for open-delta ground fault detection.
Installation Guidelines
- Mounting: Secure the transformer to a flat, stable surface using the mounting holes on the base plate. Ensure the mounting surface can support the 42.15kg weight.
- Clearance: Maintain adequate clearance around the transformer for ventilation and maintenance access. Follow local electrical codes for minimum clearance requirements.
- Primary Connection: Connect the primary terminals (A, N) to the 35kV power system using appropriate high-voltage cables and connectors. Ensure proper torque specifications are followed.
- Secondary Connection: Connect secondary terminals to metering devices, protection relays, or monitoring equipment according to the wiring diagram. Use shielded cables for secondary circuits to minimize electromagnetic interference.
- Grounding: Ensure proper grounding of the transformer base and secondary circuit neutral point for safety and accurate measurement.
Epoxy Resin Features
- Superior Insulation: Epoxy resin provides excellent dielectric strength with rated insulation level up to 40.5/80/185kV
- Moisture Resistance: Cast-resin construction prevents moisture ingress, ensuring stable performance in humid environments
- Mechanical Strength: Epoxy resin housing offers high impact resistance and structural integrity
- Maintenance-Free: Sealed epoxy design eliminates the need for regular insulation testing or oil maintenance
- Long Service Life: Epoxy resin insulation resists aging and maintains performance over decades of operation
Standards
- GB1207-2006 (Instrument transformers – Part 3: Inductive voltage transformers)
- IEC60044-2:2003 (Instrument transformers – Part 2: Inductive voltage transformers)
- Customer-specific requirements available on request
Selection Guide
When selecting the JDZX9-35G/210 voltage transformer, consider the following factors:
- Accuracy Class: Choose 0.2 for revenue metering, 0.5 for monitoring applications, 1.0 for general measurement, 3(6)P for protection applications
- Winding Configuration: Select three-winding (Y/△) for basic metering and protection, or five-winding for dual secondary outputs and enhanced redundancy
- Burden Requirements: Ensure the rated output matches the connected load (metering devices, relays) to maintain accuracy
- Environmental Conditions: Verify ambient temperature (-5°C to +40°C) and altitude (≤1000m standard) match your installation environment
Ordering Information
When ordering the JDZX9-35G/210 voltage transformer, please specify:
- Model: JDZX9-35G/210
- Rated voltage ratio (e.g., 35/√3 / 0.1/√3 / 0.1/3 kV)
- Accuracy class and rated output (e.g., 0.2/3(6)P, 30/100VA)
- Rated frequency (50Hz or 60Hz)
- Quantity required
- Any special requirements or custom specifications