JLSZV-6/10W Stainless Steel Corrosion-Resistant Combined Transformer with Meter Box

JLSZV-6/10W Stainless Steel Corrosion-Resistant Combined Transformer with Meter Box

JLSZV-6/10W outdoor epoxy cast-resin combined transformer for 6kV and 10kV distribution networks, integrating CT and PT functions with meter box.

  • Outdoor three-phase CT PT metering unit for 6kV and 10kV systems
  • Integrated meter box for complete metering solution
  • Multiple voltage ratios: 3000/100, 6000/100, 10000/100
  • CT primary current range: 5A to 200A
  • Epoxy cast-resin insulation for outdoor environments
  • Compliant with GB17201-2006

Product Overview

The JLSZV-6/10W combined transformer is an outdoor stainless steel corrosion-resistant combined transformer designed for 6kV and 10kV medium-voltage distribution systems. This CT PT combined transformer integrates voltage transformer (PT) and current transformer (CT) functions in a single epoxy cast-resin assembly with stainless steel enclosure, providing accurate current and voltage signals for energy metering and protection applications in harsh outdoor environments.

As a 6kV 10kV combined transformer with multiple voltage class options (3.6/25/40kV, 7.2/32/60kV, 12/42/75kV), the JLSZV-6/10W is suitable for outdoor pole-mounted installations, compact substations, and industrial distribution systems requiring high-accuracy metering. The stainless steel metering box provides superior corrosion resistance, making it ideal for coastal areas, chemical plants, and environments with high humidity or salt spray exposure.

This corrosion-resistant outdoor metering box 6kV 10kV features a compact design with integrated meter box, supporting current range from 5A to 200A and complying with GB17201-2006 standards for precision metering applications in demanding environments.

Product Display

JLSZV-6/10W Product Display - Technical Summary
JLSZV-6/10W Product Display - Reliable Outdoor Combined Transformer

JLSZV-6/10W Product Display

[Product images to be added]

Application Position

The JLSZV-6/10W is installed outdoors on poles, in substations, or at distribution points. The stainless steel enclosure provides superior protection against corrosion, weather, and mechanical damage, ensuring long-term reliability in harsh environments. The primary terminals connect to the three-phase 6kV or 10kV circuit, while the secondary terminal box supplies voltage and current signals to active energy meters, reactive energy meters, and monitoring instruments.

Main Applications

  • 6kV and 10kV outdoor distribution networks requiring pole-mounted metering
  • Compact substations with integrated CT PT measurement
  • Industrial distribution systems with 6kV or 10kV incoming supply
  • High-accuracy revenue metering for utility billing
  • Protection relay applications requiring precise current signals
  • Outdoor metering cabinets in harsh environments
  • Projects requiring GB17201-2006 compliance

Application Case Studies

Application Scenario 1: Coastal Distribution Metering
Utilities deploy the JLSZV-6/10W stainless steel combined transformer in coastal areas for revenue billing and load monitoring in 6kV and 10kV distribution networks. The corrosion-resistant stainless steel enclosure provides reliable performance in environments with salt spray exposure and high humidity, where standard enclosures would degrade rapidly. The integrated CT PT design reduces installation space and wiring complexity.

Application Scenario 2: Chemical Plant Metering
Chemical plants and industrial facilities with 6kV or 10kV incoming supply require accurate energy measurement in corrosive atmospheres. The JLSZV-6/10W stainless steel combined transformer resists chemical vapors and corrosive gases that would damage standard enclosures. The corrosion-resistant design ensures long-term stability without maintenance in demanding chemical processing environments.

Application Fit

Suitable For

  • Outdoor 6kV and 10kV metering points requiring pole-mounted installation
  • Compact substations with integrated CT PT measurement
  • Industrial facilities with 6kV or 10kV incoming supply
  • Applications requiring current range from 5A to 200A
  • Projects requiring GB17201-2006 compliance
  • Distribution networks requiring high-accuracy metering
  • Environments requiring epoxy cast-resin insulation
  • Indoor-only compact switchgear applications
  • Applications requiring separate CT and PT bodies
  • Protection-only applications where metering accuracy is not required
  • 35kV system applications (use JLSZV-35W model instead)
  • Applications with space constraints requiring smaller footprint

Installation Conditions

  • Installation position: Outdoor pole-mounted, substation, or distribution points
  • Ambient temperature: -15°C to +55°C
  • Maximum altitude: ≤ 4500m (no derating required)
  • Enclosure: Stainless steel corrosion-resistant construction
  • Insulation: Epoxy cast-resin internal insulation
  • Grounding: Connect grounding terminal per local electrical codes and metering standards
  • Maintenance: Stainless steel enclosure requires minimal maintenance, even in corrosive environments

Technical Parameters

The JLSZV-6/10W is an outdoor stainless steel corrosion-resistant combined transformer for 6kV and 10kV systems with three-phase design. Operating temperature -15°C to +55°C, altitude up to 4500m, compliant with GB17201-2006. Features stainless steel enclosure for superior corrosion resistance and epoxy cast-resin internal insulation.

Voltage Transformer Data

Rated Voltage
Ratio
Accuracy
Class
Rated
Output
Limit
Output
Rated Insulation
Level (kV)
3000/100 0.2 15 VA 300 VA 3.6/25/40
6000/100 0.5 30 VA 7.2/32/60
10000/100 0.5 30 VA 12/42/75

Current Transformer Data

Rated Current
Ratio
Accuracy
Class
Rated
Output
1s Thermal
Current
Dynamic
Current
Rated Insulation
Level (kV)
5 – 200/5 0.2S / 0.2 7.5 / 10 VA 80 × I1n 200 × I1n 12/42/75

Installation & Dimensions

Dimension Reference

JLSZV-6/10W Installation Diagram

View Key
Dimensions
Application
Note
Front View Width 436mm; Height 370mm; Spacing 218mm Three bushings with terminal box
Side View Height 675+2mm; Width 306/398mm Profile with nameplate
Top View Length 628mm; Width 310/360mm Six connection points layout
Meter Box Width 440mm; Base 480mm; Depth 198mm Integrated watt-hour meter compartment

Wiring Diagram

JLSZV-6/10W Wiring Diagram

[Wiring diagram to be added]

Installation Guidelines

  • Confirm AP1/AP2 and CP1/CP2 terminal sequence before commissioning
  • CT secondary circuits must not be open-circuited during operation
  • PT secondary terminals provide voltage input to meters and monitoring devices
  • CT secondary terminals provide current input to active and reactive energy meters
  • Grounding and meter box wiring should follow the approved project wiring diagram
  • Epoxy cast-resin construction must be properly grounded for safety

Standards Compliance

The JLSZV-6/10W combined transformer complies with GB17201-2006 for combined instrument transformers. For international projects, compliance should be aligned with applicable IEC instrument transformer standards and local utility metering rules.

Selection Guide

Select by system voltage: Use JLSZV-6/10W for 6kV systems (7.2kV class insulation) or 10kV systems (12kV class insulation).

Select by current ratio: Determine CT primary current according to actual load current. Supports 5A to 200A primary current range.

Select by metering accuracy: Use 0.2S CT accuracy for high-accuracy energy metering. PT accuracy classes include 0.2 and 0.5.

Select by voltage ratio: Choose 3000/100, 6000/100, or 10000/100 according to network voltage and meter input requirement.

Ordering Information

When ordering the JLSZV-6/10W combined transformer, please specify:

  • Model: JLSZV-6/10W
  • System voltage: 6kV or 10kV
  • PT ratio: 3000/100, 6000/100, or 10000/100
  • CT primary current: 5A to 200A (specify exact value)
  • CT secondary current: 5A
  • CT accuracy class: 0.2S or 0.2
  • PT accuracy class: 0.2 or 0.5
  • Installation type: Outdoor pole-mounted
  • Quantity

FAQs

The JLSZV-6/10W combined transformer is an outdoor stainless steel corrosion-resistant combined transformer used for 6kV and 10kV medium-voltage metering applications. It integrates CT and PT functions in one unit with stainless steel enclosure, providing accurate current and voltage signals for energy metering and protection in harsh outdoor environments including coastal areas and chemical plants.

The JLSZV-6/10W supports three voltage ratios: 3000/100 for 3kV systems, 6000/100 for 6kV systems, and 10000/100 for 10kV systems. Each ratio has corresponding insulation levels to ensure safe operation.

The 6kV 10kV combined transformer supports CT primary current from 5A to 200A. This range accommodates various load conditions in distribution networks without requiring multiple metering units.

Use 7.2kV class for the 6kV version and 12kV class for the 10kV version. The insulation levels are 7.2/32/60kV and 12/42/75kV respectively.

The JLSZV-6/10W combined transformer complies with GB17201-2006 for combined instrument transformers, ensuring compatibility with Chinese standards and international requirements.

CT accuracy classes include 0.2S and 0.2. PT accuracy classes include 0.2 and 0.5. Use 0.2S for high-precision revenue metering applications.

Yes, the JLSZV-6/10W includes an integrated meter box (440mm × 480mm × 198mm) for watt-hour meters, providing a complete metering solution in one compact unit.

Confirm system voltage (6kV or 10kV), PT ratio, CT primary current, CT secondary current, accuracy classes, rated burden, installation type (outdoor pole-mounted), and quantity.

Inquiry for JLSZV-6/10W Stainless Steel Corrosion-Resistant Combined Transformer with Meter Box:

Send your project requirements. Our team will reply with technical details and quotation.

Fast response Technical support OEM / ODM