JLSZV8-10W/340 Outdoor Epoxy Cast-Resin Combined Transformer Metering Box

JLSZV8-10W/340 Outdoor Epoxy Cast-Resin Combined Transformer Metering Box

JLSZV8-10W/340 outdoor epoxy cast-resin combined transformer metering box for 10kV distribution networks, integrating CT and PT functions with metal enclosure.

  • Outdoor three-phase CT PT metering unit for 10kV systems
  • Metal enclosure with 340mm terminal spacing
  • Wide CT primary current range: 7.5A to 600A
  • Epoxy cast-resin insulation for outdoor environments
  • Operating temperature: -15°C to +55°C
  • Compliant with GB20840.4-2015

Product Overview

The JLSZV8-10W/340 combined transformer is an outdoor epoxy cast-resin three-phase measurement device designed for 10kV medium-voltage distribution systems. This CT PT combined transformer integrates voltage transformer (PT) and current transformer (CT) functions in a single metal enclosure, providing accurate current and voltage signals for energy metering and protection applications in outdoor substations and distribution networks.

As a 10kV combined transformer metering box with 12kV class insulation (12/42/75kV), the JLSZV8-10W/340 is suitable for outdoor pole-mounted installations, compact substations, and industrial distribution systems requiring high-accuracy metering. The epoxy cast-resin metering transformer design ensures excellent insulation performance, moisture resistance, and long-term reliability in demanding outdoor environments.

This outdoor metering box 10kV features a compact metal enclosure with 340mm terminal spacing, supporting wide current range from 7.5A to 600A and complying with GB20840.4-2015 standards for precision metering applications.

Product Display

JLSZV8-10W/340 Product Display

JLSZV8-10W/340 Product Display - Why Choose This Model
JLSZV8-10W/340 Product Display - Reliable Metering Performance

[Product images to be added]

Application Position

The JLSZV8-10W/340 is installed outdoors on poles, in substations, or at distribution points. The metal enclosure provides protection against weather and mechanical damage. The primary terminals connect to the three-phase 10kV circuit, while the secondary terminal box supplies voltage and current signals to active energy meters, reactive energy meters, and monitoring instruments.

Main Applications

  • 10kV outdoor distribution networks requiring pole-mounted metering
  • Compact substations with integrated CT PT measurement
  • Industrial distribution systems with 10kV incoming supply
  • High-accuracy revenue metering for utility billing
  • Protection relay applications requiring precise current signals
  • Outdoor metering cabinets in harsh environments
  • Projects requiring GB20840.4-2015 compliance

Application Case Studies

Application Scenario 1: Pole-Mounted Distribution Metering
Utilities deploy the JLSZV8-10W/340 combined transformer on concrete poles for revenue billing and load monitoring in 10kV distribution networks. The compact metal enclosure with 340mm terminal spacing provides reliable performance in outdoor environments with temperature variations and humidity exposure. The integrated CT PT design reduces installation space and wiring complexity.

Application Scenario 2: Industrial Substation Metering
Industrial facilities with 10kV incoming supply require accurate energy measurement for cost allocation and load monitoring. The 10kV combined transformer metering box supports wide current range from 7.5A to 600A, accommodating various load conditions. The epoxy cast-resin insulation ensures long-term stability without maintenance in demanding industrial environments.

Application Fit

Suitable For

  • Outdoor 10kV metering points requiring pole-mounted installation
  • Compact substations with integrated CT PT measurement
  • Industrial facilities with 10kV incoming supply
  • Applications requiring wide current range from 7.5A to 600A
  • Projects requiring GB20840.4-2015 compliance
  • Distribution networks requiring high-accuracy metering
  • Environments requiring metal enclosure protection
  • Indoor-only compact switchgear applications
  • Applications requiring separate CT and PT bodies
  • Protection-only applications where metering accuracy is not required
  • 6kV system applications (use JLSZV8-6W model instead)
  • Applications with space constraints requiring smaller footprint

Installation Conditions

  • Installation position: Outdoor pole-mounted, substation, or distribution points
  • Ambient temperature: -15°C to +55°C
  • Maximum altitude: ≤ 4500m (no derating required)
  • Enclosure: Metal enclosure with ventilation slots
  • Grounding: Connect grounding terminal per local electrical codes and metering standards
  • Maintenance: Metal enclosure requires minimal maintenance in outdoor environments

Technical Parameters

The JLSZV8-10W/340 is an outdoor epoxy cast-resin combined transformer for 10kV systems with three-phase design. Operating temperature -15°C to +55°C, altitude up to 4500m, compliant with GB20840.4-2015. Features metal enclosure, 340mm terminal spacing, and wide current range from 7.5A to 600A.

Voltage Transformer Data

Rated Voltage
Ratio
Rated Insulation
Level (kV)
Accuracy Class
/ Rated Output
Limit
Output
6000/100 7.2/32/60 0.2 (2×20VA), 0.5 (2×50VA), 1.0 (2×80VA), 3.0 (2×200VA) 2×400 VA
10000/100 12/42/75 0.2 (2×20VA), 0.5 (2×50VA), 1.0 (2×80VA), 3.0 (2×200VA) 2×400 VA

Current Transformer Data

Rated Primary
Current (A)
Accuracy Class
/ Rated Output
1s Thermal
Current (kA)
Dynamic
Current (kA)
7.5 – 15 0.2S (10VA), 0.5S (10VA), 0.5 (15VA) 1.0 2.5
20 – 50 0.2S (10VA), 0.5S (10VA), 0.5 (15VA) 2.5 6.3
75 – 100 0.2S (10VA), 0.5S (10VA), 0.5 (15VA) 6.3 16
150 – 200 0.2S (10VA), 0.5S (10VA), 0.5 (15VA) 16 40
300 – 400 0.2S (10VA), 0.5S (10VA), 0.5 (15VA) 40 100
500 – 600 0.2S (10VA), 0.5S (10VA), 0.5 (15VA) 60 150

Installation & Dimensions

Dimension Reference

JLSZV8-10W/340 Installation Diagram

View Key
Dimensions
Application
Note
Front View Width 950mm (base 980mm); Height 760±5mm Three bushings with metal enclosure
Side View Depth 260mm (base 140mm); Height 305±3mm Profile with nameplate and terminal box
Top View Terminal layout with mounting holes 9-M6 mounting bolts

Wiring Diagram

JLSZV8-10W/340 Wiring Diagram

[Wiring diagram to be added]

Installation Guidelines

  • Confirm AP1/AP2, BP1/BP2 and CP1/CP2 terminal sequence before commissioning
  • CT secondary circuits must not be open-circuited during operation
  • PT secondary terminals provide voltage input to meters and monitoring devices
  • CT secondary terminals provide current input to active and reactive energy meters
  • Grounding and meter box wiring should follow the approved project wiring diagram
  • Metal enclosure must be properly grounded for safety

Standards Compliance

The JLSZV8-10W/340 combined transformer complies with GB20840.4-2015 for combined instrument transformers. For international projects, compliance should be aligned with applicable IEC instrument transformer standards and local utility metering rules.

Selection Guide

Select by system voltage: Use JLSZV8-10W/340 for 10kV systems (12kV class insulation).

Select by current ratio: Determine CT primary current according to actual load current. Supports 7.5A to 600A primary current range in multiple segments.

Select by metering accuracy: Use 0.2S CT accuracy for high-accuracy energy metering. Use 0.5S or 0.5 according to metering specification.

Select by voltage ratio: Choose 6000/100 or 10000/100 according to network voltage and meter input requirement.

Ordering Information

When ordering the JLSZV8-10W/340 combined transformer, please specify:

  • Model: JLSZV8-10W/340
  • System voltage: 10kV
  • PT ratio: 6000/100 or 10000/100
  • CT primary current: 7.5A to 600A (specify exact value)
  • CT secondary current: 5A
  • CT accuracy class: 0.2S, 0.5S, or 0.5
  • PT accuracy class: 0.2, 0.5, 1.0, or 3.0
  • Installation type: Outdoor pole-mounted
  • Quantity

FAQs

The JLSZV8-10W/340 combined transformer is an outdoor epoxy cast-resin combined transformer used for 10kV medium-voltage metering applications. It integrates CT and PT functions in one metal enclosure, providing accurate current and voltage signals for energy metering and protection in outdoor pole-mounted installations and substations.

The 340mm terminal spacing provides increased creepage distance, reducing the risk of flashover in high-pollution environments such as coastal areas and industrial zones. This design ensures reliable operation in harsh outdoor conditions.

The 10kV combined transformer metering box supports CT primary current from 7.5A to 600A in multiple segments. The wide range accommodates various load conditions without requiring multiple metering units.

Use 12kV class for the 10kV version. The insulation level is 12/42/75kV, meeting international standards for 10kV systems.

The JLSZV8-10W/340 combined transformer complies with GB20840.4-2015 for combined instrument transformers, ensuring compatibility with Chinese standards and international requirements.

CT accuracy classes include 0.2S, 0.5S, and 0.5. PT accuracy classes include 0.2, 0.5, 1.0, and 3.0. Use 0.2S for high-precision revenue metering applications.

Yes, the JLSZV8-10W/340 can be installed indoors, but it is primarily designed for outdoor pole-mounted applications. The metal enclosure provides protection against weather and mechanical damage in outdoor environments.

Confirm system voltage (10kV), PT ratio, CT primary current, CT secondary current, accuracy classes, rated burden, installation type (outdoor pole-mounted), and quantity.

Inquiry for JLSZV8-10W/340 Outdoor Epoxy Cast-Resin Combined Transformer Metering Box:

Send your project requirements. Our team will reply with technical details and quotation.

Fast response Technical support OEM / ODM