JSJWF-10W Outdoor Oil-Filled Three-Phase Voltage Transformer

JSJWF-10W Outdoor Oil-Filled Three-Phase Voltage Transformer

JSJWF-10W outdoor oil-filled three-phase voltage transformer for 10kV systems.

  • Oil-immersed insulation provides excellent dielectric strength and thermal dissipation for outdoor use
  • High output capacity up to 600VA meets demanding three-phase measurement and protection requirements
  • Multiple accuracy classes 0.2/0.5/1.0 with flexible Y/△ or Y/Y/△ connection options
  • Wide operating range -40°C to +40°C suitable for extreme climate conditions
  • Compact three-phase structure with 142kg weight simplifies installation requirements
  • Customizable for different countries, regions, and project requirements

Product Overview

The JSJWF-10W voltage transformer is an outdoor oil-filled three-phase measurement device designed for 10kV medium-voltage distribution systems. This three-phase voltage transformer features advanced oil-immersed insulation technology, providing excellent dielectric strength and reliable operation in harsh outdoor environments.

The JSJWF-10W delivers precise three-phase voltage measurement for protection and metering applications with multiple accuracy classes (0.2, 0.5, 1.0) and flexible connection configurations (Y/△ three-winding or Y/Y/△ four-winding). The oil-immersed construction ensures superior thermal performance while providing 600VA maximum output capacity. Wide temperature range operation (-40°C to +40°C) makes it suitable for extreme climate conditions.

Product Display

JSJWF-10W Product Display
JSJWF-10W Product Display - Outdoor Oil-Filled Three-Phase Voltage Transformer
JSJWF-10W Product Display - Engineered for Reliability

Application Position

The JSJWF-10W is installed in outdoor switchgear, substations, and distribution networks where reliable three-phase voltage measurement is required. The oil-immersed insulation provides excellent dielectric strength and thermal dissipation for continuous outdoor operation. Multiple connection configurations (Y/△ or Y/Y/△) accommodate various protection and metering system requirements.

Main Applications

  • 10kV outdoor distribution networks
  • Substations requiring three-phase voltage measurement
  • Industrial facilities with medium-voltage supply
  • Protection relay voltage input
  • Power quality monitoring and metering
  • Applications requiring high output capacity (up to 600VA)

Application Case Studies

Application Scenario 1: Substation Three-Phase Voltage Measurement
Utilities deploy the JSJWF-10W oil-filled voltage transformer in 10kV substations for protection relay input and energy metering. The Y/△ connection configuration provides both metering outputs (star-connected) and protection outputs (open delta), ensuring comprehensive three-phase system monitoring while the oil-immersed design delivers reliable performance in outdoor environments.

Application Scenario 2: Industrial Medium-Voltage Metering
Industrial facilities with 10kV incoming supply require accurate three-phase voltage measurement for power quality monitoring and protection coordination. The JSJWF-10W offers multiple accuracy classes (0.2, 0.5, 1.0) to meet different measurement requirements, with 600VA maximum output capacity for various burden conditions and the Y/Y/△ four-winding configuration for enhanced system flexibility.

Application Fit

Suitable For

  • Outdoor 10kV three-phase voltage measurement
  • Substations with protection relay requirements
  • Industrial facilities with medium-voltage supply
  • Power quality monitoring applications
  • Applications requiring high output capacity
  • Environments with extreme temperature variations
  • Indoor-only compact switchgear applications
  • Current measurement applications (use CT instead)
  • High-voltage systems above 12kV (use higher voltage class models)
  • Applications requiring maintenance-free dry-type design

Installation Conditions

  • Installation position: Outdoor switchgear, substations, or distribution points
  • Ambient temperature: -40°C to +40°C
  • Altitude: ≤ 1000m (standard), higher altitude available on request
  • Insulation: Oil-immersed
  • Frequency: 50Hz or 60Hz
  • Connection: Y/△ (three-winding) or Y/Y/△ (four-winding)
  • Maintenance: Periodic oil level and quality inspection recommended

Technical Parameters

The JSJWF-10W is an outdoor oil-filled three-phase voltage transformer for 10kV systems. Operating temperature -40°C to +40°C, compliant with GB20840.3-2013 and IEC61869-3:2011. Features oil-immersed insulation, multiple connection configurations, and high output capacity.

VT Data

Rated Voltage
(kV)
Insulation Level
(kV)
Accuracy Class
& Rated Output (VA)
Max Output
(VA)
10/√3 : 0.1/√3 : 0.1/3 12/42/75 0.2/3P: 3×30/100
0.5/3P: 3×80/100
1.0/3P: 3×150/100
600
10/√3 : 0.1/√3 : 0.1/√3 : 0.1/3 12/42/75 0.2/0.5/3P: 3×30/3×40/50
0.2/0.5/6P: 3×30/3×40/50
500

Installation

Dimension Reference

JSJWF-10W Installation Diagram

View Key
Dimensions
Application
Note
Front View Width 550±2mm / 565±2mm Four bushings, nameplate, oil drain hole
Side View Height 338±2mm; Width 280/295mm Profile with primary bushing and lifting hook
Top View 520 x 605 x 335mm Terminal layout and mounting holes

Weight: Approximately 142kg

Wiring Diagram

JSJWF-10W Wiring Diagram

Installation Guidelines

  • Install in outdoor switchgear or substation with adequate ventilation
  • Connect primary terminals A, B, C to three-phase system
  • Connect secondary terminals to meters and protection devices
  • Ensure proper grounding of secondary circuit neutral point
  • Verify voltage ratio matches system requirements before commissioning
  • Check oil level and insulation resistance before energizing
  • For Y/△ connection, connect tertiary winding in open delta for ground fault detection

Oil-Immersed Features

The JSJWF-10W incorporates advanced oil-immersed insulation technology including:

  • Excellent dielectric strength for high-voltage applications
  • Superior thermal dissipation for continuous operation
  • Wide temperature range operation (-40°C to +40°C)
  • Proven reliability in outdoor environments

Standards

The JSJWF-10W oil-filled voltage transformer complies with GB20840.3-2013 and IEC61869-3:2011 for voltage transformers, ensuring compatibility with Chinese and international standards for medium-voltage measurement applications.

Selection Guide

Select by system voltage: JSJWF-10W is designed for 10kV systems with 12/42/75kV insulation level.

Select by accuracy class: Use 0.2 for high-precision metering, 0.5 for standard metering, or 1.0 for general measurement.

Select by connection type: Choose Y/△ (three-winding) for basic applications or Y/Y/△ (four-winding) for enhanced system flexibility.

Select by rated output: Choose rated output based on connected burden requirements (up to 600VA maximum).

Ordering Information

When ordering the JSJWF-10W oil-filled voltage transformer, please specify:

  • Model: JSJWF-10W
  • System voltage: 10kV
  • Accuracy class: 0.2, 0.5, or 1.0
  • Rated output: Specify VA value from table
  • Connection type: Y/△ (three-winding) or Y/Y/△ (four-winding)
  • Frequency: 50Hz or 60Hz
  • Installation type: Outdoor
  • Quantity

FAQs

Three-phase oil-immersed voltage transformer uses transformer oil as insulation medium and measures all three phases simultaneously. This provides excellent dielectric strength and thermal dissipation for reliable three-phase voltage measurement in medium-voltage applications.

Y/△ connection has three windings (primary star, secondary star, tertiary open delta) for basic metering and protection. Y/Y/△ connection has four windings, providing additional secondary outputs for enhanced system flexibility and redundancy.

Three accuracy classes are available: 0.2 for high-precision metering, 0.5 for standard metering, and 1.0 for general measurement. Select based on your measurement accuracy requirements and connected burden.

Oil-immersed transformers require periodic oil level checks and oil quality inspection. The oil may need replacement after extended service. Regular maintenance ensures long-term reliability and accurate measurement performance.

The JSJWF-10W complies with GB20840.3-2013 and IEC61869-3:2011 for voltage transformers, ensuring compatibility with Chinese and international standards for medium-voltage measurement applications.

Confirm model (JSJWF-10W), system voltage (10kV), accuracy class (0.2, 0.5, or 1.0), rated output, connection type (Y/△ or Y/Y/△), frequency (50Hz or 60Hz), installation type (outdoor), and quantity.

Inquiry for JSJWF-10W Outdoor Oil-Filled Three-Phase Voltage Transformer:

Send your project requirements. Our team will reply with technical details and quotation.

Fast response Technical support OEM / ODM