ZW20A-12 Outdoor High-Voltage Pole-Mounted Vacuum Circuit Breaker - featured

ZW20A-12 Outdoor High-Voltage Pole-Mounted Vacuum Circuit Breaker

ZW20A-12: 12kV Pole-Mounted Vacuum Circuit Breaker, SF6 Insulated

  • 12 kV 50 Hz pole-mounted VCB, vacuum + SF6 insulation
  • 630 A or 1250 A rating, 16/20/25 kA breaking capacity
  • 42 kV power-frequency and 75 kV impulse withstand
  • Sealed enclosure for -40 to +40 degC outdoor service
  • 10000-operation mechanical life, manual or motorised
  • Built-in CTs for relay interfacing and automation

Product Overview

The ZW20A-12 is an outdoor pole-mounted vacuum circuit breaker for 12 kV 50 Hz three-phase AC distribution systems, providing switching and protection against load, overload and short-circuit currents in substations, industrial plants and rural networks. Rated currents of 630 A and 1250 A combine with breaking capacities of 16, 20 and 25 kA, and the vacuum-plus-SF6 insulated design supports remote monitoring and distribution automation.

Product Display

ZW20A-12 Outdoor High-Voltage Pole-Mounted Vacuum Circuit Breaker - display

ZW20A-12 Outdoor High-Voltage Pole-Mounted Vacuum Circuit Breaker - poster_display

Model Designation

ZW20A-12 Outdoor High-Voltage Pole-Mounted Vacuum Circuit Breaker - model

Model format: ZW 20 − 12 / T □ − □

  • ZW — Vacuum circuit breaker
  • 20 — Product series design number
  • 12 — Rated voltage (kV)
  • T — Spring-operated mechanism
  • First □ — Rated current (A)
  • Second □ — Rated short-circuit breaking current (kA)

Service Conditions

  • Ambient temperature: −40 °C to +40 °C
  • Altitude: not exceeding 1000 m above sea level
  • Relative humidity: daily average ≤ 95%, monthly average ≤ 90%
  • Seismic intensity: not exceeding degree 8
  • Installation site free from fire, explosion risk, severe pollution and chemical corrosion

Construction

The ZW20A-12 pairs vacuum arc extinction with SF6 gas insulation on the proven ZW20-12 platform, giving high dielectric strength and hermetic sealing. A compact spring-operated mechanism with direct chain drive and multi-stage tripping keeps mechanical reliability high, while the bracelet contact structure of the main current path limits contact resistance and thermal rise.

The sealed enclosure holds stable operation through high humidity, dust and wide temperature swings with zero SF6 leakage and explosion-proof performance. Built-in current transformers interface with protection relays, primary terminals are marked P1/P2 with instrument-transformer secondary terminals S1/S2, and both manual and motorised operation are supported.

Technical Data

Item Unit Value
Rated Voltage kV 12
Rated Frequency Hz 50
Rated Current A 630
1250
Rated Short-Circuit Breaking Current kA 16
20
25
Rated Short-Circuit Making Current (peak) kA 40
50
63
Rated Short-Time Withstand Current (3 s) kA 16
20
25
Power Frequency Withstand Voltage (1 min) kV 42
Lightning Impulse Withstand Voltage kV 75
Mechanical Life Operations 10000
SF6 Gas Pressure (gauge, 20 °C) MPa 0.01
Selection note: choose the rated current and breaking capacity from the system load profile and the prospective fault level at the installation point, and verify the matching peak-making and three-second withstand ratings.

Standards

Manufactured and tested in accordance with IEC and GB standards for high-voltage AC circuit breakers, including IEC 62271-100 and GB 1984.

Technical note: routine-test reports are issued with each shipment; type-test reports and third-party certification documents are available on request.

Installation & Dimensions

Installation Diagram

The breaker mounts on standard utility poles with clear phase spacing and secure anchoring points to remain mechanically stable under wind and ice loading.

Dimension Value (mm)
Overall Height 1850
Overall Width (phase-to-phase) 630
Mounting Bracket Height 1200
Primary Terminal Spacing (P1–P2) 350
Secondary Terminal Block Size 120 x 80
Safety notice: always de-energize and earth the system before handling, verify the 0.01 MPa gauge SF6 pressure during installation and use appropriate personal protective equipment.

FAQs

Breaking capacities of 16 kA, 20 kA and 25 kA are offered, each with matching peak-making and three-second withstand ratings. Select the rating above your calculated prospective fault level; our engineers can recommend a rating from your load profile.

Yes. The unit is rated for ambient temperatures from -40 °C to +40 °C, subject to site verification, and installation altitude must not exceed 1000 m. Advise your site climate data for confirmation of low-temperature operation.

Selection depends on your system load profile, temperature-rise margin and planned capacity growth. Confirm the continuous load current and future extension before ordering; our engineering team can check the rating against your network data.

Every breaker passes standard routine tests per the applicable IEC requirements, covering mechanical operation, secondary wiring and dielectric performance. Specific type tests or third-party certification are subject to confirmation; request the detailed test report from our sales team.

Lead times depend on order quantity and customisation such as CT ratios, controllers and communication options. Contact us with your required quantity and configuration for an accurate delivery schedule and quotation.

It is installed on poles in 12 kV 50 Hz outdoor distribution networks, including rural electrification, industrial supply and smart-grid automation schemes where remote monitoring and sectionalising are required. Verify local grid standards before specification.