Product Overview
The JDZ9-35Q JDZXF9-35Q JDZX9-35Qvoltage transformer is an indoor epoxy cast-resin single-phase measurement device designed for 35kV medium-voltage distribution systems. This advanced voltage transformer features epoxy resin cast insulation technology, providing excellent dielectric strength and maintenance-free operation for reliable performance in indoor environments.
The JDZ9-35Q series delivers precise voltage measurement for energy metering, voltage monitoring, and relay protection applications with multiple accuracy classes (0.2, 0.5, 1.0) and various winding configurations. The epoxy resin cast construction ensures superior insulation performance with 40.5/95/200kV insulation level while providing up to 600VA thermal limit output capacity. Compact design with 107kg weight simplifies installation and reduces structural support requirements.
Product Display



Application Position
The JDZ9-35Q series is installed in indoor switchgear, substations, and distribution networks where reliable single-phase voltage measurement is required. The epoxy resin insulation provides excellent moisture resistance and long-term durability for indoor operation. Units are typically connected in three-phase configuration with star-connected primary and secondary windings for accurate voltage measurement and protection.
Main Applications
- 35kV indoor distribution networks
- Substations requiring voltage measurement
- Industrial facilities with medium-voltage supply
- Energy metering applications
- Voltage monitoring and relay protection
- Indoor power distribution systems
Application Case Studies
Application Scenario 1: Substation Voltage Measurement
Utilities deploy JDZ9-35Q epoxy cast-resin voltage transformers in 35kV indoor substations for energy metering and protection. The multiple model variants (JDZ9-35Q, JDZF9-35Q, JDZX9-35Q, JDZXF9-35Q) provide flexibility for different measurement requirements, from basic single-winding to complex multi-winding configurations. The epoxy resin insulation ensures reliable performance in indoor environments with 40.5/95/200kV insulation level and maintenance-free operation.
Application Scenario 2: Industrial Medium-Voltage Metering
Industrial facilities with 35kV incoming supply require accurate voltage measurement for energy management and protection coordination. The JDZ9-35Q series offers multiple accuracy classes (0.2, 0.5, 1.0) to meet different measurement requirements, with up to 600VA thermal limit output capacity for various burden conditions. The compact design simplifies installation in space-constrained switchgear panels.
Application Fit
Suitable For
- Indoor 35kV voltage measurement
- Substations with metering and protection requirements
- Industrial facilities with medium-voltage supply
- Voltage monitoring applications
- Relay protection systems
- Environments requiring maintenance-free operation
Not Recommended For
- Outdoor installation applications (use outdoor-rated models)
- Current measurement applications (use CT instead)
- High-voltage systems above 40.5kV (use higher voltage class models)
- Applications requiring three-phase measurement in single unit
Installation Conditions
- Installation position: Indoor switchgear, substations, or distribution points
- Ambient temperature: -5°C to +40°C
- Altitude: ≤ 1000m (standard), higher altitude available on request
- Insulation: Epoxy resin cast
- Frequency: 50Hz or 60Hz
- Connection: Single-phase (three units for three-phase system)
- Maintenance: Minimal maintenance required (epoxy resin design)
Technical Parameters
The JDZ9-35Q series includes four model variants for different measurement and protection requirements. All models feature indoor epoxy cast-resin construction for 35kV systems. Operating temperature -5°C to +40°C, compliant with GB20840.1.3 and IEC61869-1.3 standards.
| Model | Rated Voltage (kV) |
Accuracy Class & Rated Output (VA) |
Thermal Limit Output (VA) |
Insulation Level (kV) |
|---|---|---|---|---|
| JDZ9-35Q | 35/0.1 | 0.2: 50 0.5: 120 1.0: 250 |
600 | 40.5/95/200 |
| JDZF9-35Q | 35/0.1/0.1 | 0.2: 20 0.5: 40 1.0: 60 |
2×300 | 40.5/95/200 |
| JDZX9-35Q | 35/√3 : 0.1/√3 : 0.1/3 | 0.2/3P(6P): 30 0.5/3P(6P): 60 1.0: 150 |
600 | 40.5/95/200 |
| JDZXF9-35Q | 35/√3 : 0.1/√3 : 0.1/√3 : 0.1/3 | 0.2/0.5/3P(6P): 15/20/100 | 2×300 | 40.5/95/200 |
Note 1: JDZ9-35Q – Single secondary winding for basic voltage measurement.
Note 2: JDZF9-35Q – Dual secondary windings for separate metering and protection circuits.
Note 3: JDZX9-35Q – Single-phase with residual voltage winding for ground fault detection.
Note 4: JDZXF9-35Q – Enhanced configuration with dual secondary and residual voltage windings.
Note 5: Rated output and its relative accuracy class only one alternative per transformer.
Note 6: If user’s data go beyond the above-mentioned scopes, they may be subject to an agreement between manufacturer and purchaser.
Installation
Dimension Reference

Overall dimensions: Top width 390mm, base width 545mm, height 495mm. Weight: approximately 107kg. Mounting holes: 4-φ13 on base plate.
Wiring Diagram

Single-phase connection: Primary terminals A, B; Secondary terminals 1a-1b (metering), 2a-2b (protection). Three-phase V-connection available for open-delta configuration.
Installation Guidelines
- Mounting: Secure the transformer to a flat, stable surface using the mounting holes on the base plate. Ensure the mounting surface can support the 107kg weight.
- Clearance: Maintain adequate clearance around the transformer for ventilation and maintenance access. Follow local electrical codes for minimum clearance requirements.
- Primary Connection: Connect the primary terminals (A, B) to the 35kV power system using appropriate high-voltage cables and connectors. Ensure proper torque specifications are followed.
- Secondary Connection: Connect secondary terminals to metering devices, protection relays, or monitoring equipment according to the wiring diagram. Use shielded cables for secondary circuits to minimize electromagnetic interference.
- Grounding: Ensure proper grounding of the transformer base and secondary circuit neutral point for safety and accurate measurement.
Epoxy Resin Features
- Superior Insulation: Epoxy resin provides excellent dielectric strength with rated insulation level up to 40.5/95/200kV
- Moisture Resistance: Cast-resin construction prevents moisture ingress, ensuring stable performance in humid environments
- Mechanical Strength: Epoxy resin housing offers high impact resistance and structural integrity
- Maintenance-Free: Sealed epoxy design eliminates the need for regular insulation testing or oil maintenance
- Long Service Life: Epoxy resin insulation resists aging and maintains performance over decades of operation
Standards
- GB20840.1.3 (Instrument transformers – Part 3: Inductive voltage transformers)
- IEC61869-1.3 (Instrument transformers – Part 3: Inductive voltage transformers)
- Customer-specific requirements available on request
Selection Guide
When selecting the JDZ9-35Q series voltage transformer, consider the following factors:
- Model Selection: Choose JDZ9-35Q for basic measurement, JDZF9-35Q for dual secondary, JDZX9-35Q for ground fault detection, or JDZXF9-35Q for comprehensive protection
- Accuracy Class: Choose 0.2 for revenue metering, 0.5 for monitoring applications, 1.0 for general measurement, 3P(6P) for protection applications
- Burden Requirements: Ensure the rated output matches the connected load (metering devices, relays) to maintain accuracy
- Environmental Conditions: Verify ambient temperature (-5°C to +40°C) and altitude (≤1000m standard) match your installation environment
Ordering Information
When ordering the JDZ9-35Q series voltage transformer, please specify:
- Model: JDZ9-35Q / JDZF9-35Q / JDZX9-35Q / JDZXF9-35Q
- Rated voltage ratio (e.g., 35/0.1 kV)
- Accuracy class and rated output (e.g., 0.2, 50VA)
- Rated frequency (50Hz or 60Hz)
- Quantity required
- Any special requirements or custom specifications