JDZ(X)2-12(35)W Outdoor Epoxy Resin Cast Voltage Transformer

JDZ(X)2-12(35)W Outdoor Epoxy Resin Cast Voltage Transformer

JDZ(X)2-12(35)W outdoor epoxy resin cast single-phase voltage transformer for 10kV and below systems.

  • Epoxy resin cast insulation provides excellent dielectric strength and arc resistance for outdoor use
  • Maintenance-free design with UV resistance and aging resistance ensures long service life
  • High precision 0.2/0.5 accuracy classes for reliable energy metering and protection
  • Flexible Y or V connection options accommodate various system configurations
  • Anti-pollution class IV rating suitable for harsh outdoor environments
  • Customizable for different countries, regions, and project requirements

Product Overview

The JDZ(X)2-12(35)W voltage transformer is an outdoor epoxy resin cast single-phase measurement device designed for 10kV and below medium-voltage distribution systems. This fully enclosed voltage transformer features advanced epoxy resin insulation technology, providing excellent dielectric strength and reliable operation in harsh outdoor environments.

The JDZ(X)2-12(35)W delivers precise voltage measurement for energy metering, voltage monitoring, and relay protection applications in neutral non-effectively grounded systems. The epoxy resin cast construction ensures superior insulation performance with arc resistance, UV resistance, aging resistance, long creepage distance, low partial discharge, and over-voltage resistance. Compact design with small volume and light weight allows installation in any direction.

Product Display

JDZX2 1235W Outdoor Epoxy Resin Cast Voltage Transformer display

JDZX2 1235W Outdoor Epoxy Resin Cast Voltage Transformer product ad image

JDZX2 1235W Outdoor Epoxy Resin Cast Voltage Transformer product poster 02

Application Position

The JDZ(X)2-12(35)W is installed in outdoor switchgear, substations, and distribution networks where reliable single-phase voltage measurement is required. The epoxy resin insulation provides excellent moisture resistance and UV protection for long-term outdoor operation. Flexible connection configurations (Y or V connection) accommodate various protection and metering system requirements.

Main Applications

  • 10kV and below outdoor distribution networks
  • Substations requiring voltage measurement
  • Industrial facilities with medium-voltage supply
  • Energy metering applications
  • Voltage monitoring and relay protection
  • Neutral non-effectively grounded systems

Application Case Studies

Application Scenario 1: Substation Voltage Measurement
Utilities deploy the JDZ(X)2-12(35)W epoxy resin voltage transformer in 10kV substations for energy metering and relay protection. The Y connection configuration provides accurate voltage signals for protection relays, while the epoxy resin insulation ensures reliable performance in outdoor environments with anti-pollution class IV rating.

Application Scenario 2: Industrial Medium-Voltage Metering
Industrial facilities with 10kV incoming supply require accurate voltage measurement for energy management and protection coordination. The JDZ(X)2-12(35)W offers flexible connection options (Y or V connection) to meet different system requirements, with compact design allowing installation in any direction and light weight simplifying installation.

Application Fit

Suitable For

  • Outdoor 10kV and below voltage measurement
  • Substations with energy metering requirements
  • Industrial facilities with medium-voltage supply
  • Voltage monitoring applications
  • Relay protection systems
  • Neutral non-effectively grounded systems
  • Indoor-only compact switchgear applications
  • Current measurement applications (use CT instead)
  • High-voltage systems above 35kV (use higher voltage class models)
  • Applications requiring three-phase measurement in single unit

Installation Conditions

  • Installation position: Outdoor switchgear, substations, or distribution points
  • Ambient temperature: -25°C to +40°C
  • Anti-pollution class: IV class
  • Insulation: Epoxy resin cast
  • Frequency: 50Hz or 60Hz
  • Connection: Y connection or V connection
  • Maintenance: Minimal maintenance required (epoxy resin design)

Technical Parameters

The JDZ(X)2-12(35)W is an outdoor epoxy resin cast single-phase voltage transformer for 10kV and below systems. Operating temperature -25°C to +40°C, anti-pollution class IV, compliant with IEC186 and GB1207-1997 standards.

Model Designation

Code Meaning
J Voltage transformer
D Single phase
Z Casting resin insulated
(X) With residual voltage winding
2 Design sequence
12(35) Highest voltage of equipment (kV)
W Outdoor installation

VT Data

Model Rated Voltage
(kV)
Accuracy
Class
Connection
Type
JDZ2-12W 12 0.2 / 0.5 Y connection
JDZX2-12W 12 0.2 / 0.5 Y connection (with residual voltage winding)
JDZ2-35W 35 0.2 / 0.5 V connection
JDZX2-35W 35 0.2 / 0.5 V connection (with residual voltage winding)

Installation

Dimension Reference

JDZ(X)2-12(35)W Installation Diagram
JDZ(X)2-12(35)W Installation Diagram

Feature Specification Application
Note
Installation Any direction Compact design allows flexible mounting
Base Square metal plate with 4 mounting holes Secure bolting to foundation
Bushings Two vertical insulators Primary and secondary connections

Wiring Diagram

JDZ(X)2-12(35)W Wiring Diagram

Installation Guidelines

  • Install in outdoor switchgear or substation with adequate ventilation
  • Connect primary terminal to voltage system
  • Connect secondary terminals to meters and protection devices
  • For Y connection, connect neutral point to system ground
  • For V connection, connect between two phases
  • Verify voltage ratio matches system requirements before commissioning
  • Check insulation resistance before energizing

Epoxy Resin Features

The JDZ(X)2-12(35)W incorporates advanced epoxy resin technology including:

  • Electric arc resistance for enhanced safety
  • UV resistance for long-term outdoor operation
  • Aging resistance for extended service life
  • Long creepage distance for anti-pollution performance
  • Low partial discharge for reliable insulation
  • Over-voltage resistance for system protection

Standards

The JDZ(X)2-12(35)W epoxy resin voltage transformer complies with IEC186 and GB1207-1997 for voltage transformers, ensuring compatibility with international and Chinese standards for medium-voltage measurement applications. Partial discharge test conditions according to GB1207-1997 are fulfilled without exception.

Selection Guide

Select by system voltage: Choose JDZ2-12W for 12kV systems or JDZ2-35W for 35kV systems.

Select by accuracy class: Use 0.2 for high-precision metering or 0.5 for standard metering.

Select by connection type: Choose Y connection for star-connected systems or V connection for phase-to-phase measurement.

Select by residual voltage winding: Choose JDZX2 model if residual voltage winding is required for ground fault detection.

Ordering Information

When ordering the JDZ(X)2-12(35)W epoxy resin voltage transformer, please specify:

  • Model: JDZ2-12W, JDZX2-12W, JDZ2-35W, or JDZX2-35W
  • System voltage: 12kV or 35kV
  • Accuracy class: 0.2 or 0.5
  • Connection type: Y connection or V connection
  • Residual voltage winding: Yes (JDZX2) or No (JDZ2)
  • Frequency: 50Hz or 60Hz
  • Installation type: Outdoor
  • Quantity

FAQs

Epoxy resin cast voltage transformer uses advanced epoxy resin insulation instead of traditional oil or porcelain. This provides excellent dielectric strength, arc resistance, UV resistance, and maintenance-free operation for reliable outdoor performance in medium-voltage applications.

Y connection (star connection) connects the transformer between phase and neutral, providing phase-to-neutral voltage measurement. V connection connects the transformer between two phases, providing phase-to-phase voltage measurement. Choose based on your system configuration and measurement requirements.

Residual voltage winding is an additional winding used for ground fault detection in neutral non-effectively grounded systems. The JDZX2 model includes this winding, while the JDZ2 model does not. Choose JDZX2 if ground fault detection is required.

The epoxy resin design requires minimal maintenance. Periodic visual inspection for physical damage is recommended. No oil maintenance or periodic cleaning is required, reducing operational costs over the service life.

The JDZ(X)2-12(35)W complies with IEC186 (international standard) and GB1207-1997 (Chinese standard) for voltage transformers, ensuring compatibility with both international and domestic medium-voltage measurement applications.

Confirm model (JDZ2-12W, JDZX2-12W, JDZ2-35W, or JDZX2-35W), system voltage (12kV or 35kV), accuracy class (0.2 or 0.5), connection type (Y or V), residual voltage winding requirement, frequency (50Hz or 60Hz), installation type (outdoor), and quantity.

Inquiry for JDZ(X)2-12(35)W Outdoor Epoxy Resin Cast Voltage Transformer:

Send your project requirements. Our team will reply with technical details and quotation.

Fast response Technical support OEM / ODM