Product Overview
The JLSZV(F)-6W and JLSZV(F)-10W are three-phase outdoor silicon rubber combined instrument transformers designed for medium voltage metering applications in challenging environments. These silicon rubber instrument transformers integrate current transformer (CT) and voltage transformer (PT) functions within a single housing, providing reliable performance in coastal areas, heavy industrial zones, and regions with high pollution levels.
Engineered with silicon rubber insulation technology, this combined transformer offers superior resistance to UV radiation, chemical exposure, and surface contamination. The hydrophobic properties of silicon rubber enable self-cleaning action under rainfall, maintaining insulation integrity even in heavily polluted atmospheres. Suitable for 50Hz or 60Hz three-phase AC systems with rated voltages of 6kV or 10kV, these outdoor combined transformers operate reliably at altitudes up to 4500m.
Product Display
![]()
![]()
![]()
Application Position
JLSZV(F)-6W and JLSZV(F)-10W silicon rubber combined transformers are deployed in the metering section of 6kV and 10kV medium voltage power distribution networks, particularly in environments where pollution resistance is critical. Installed on the high-voltage side of distribution transformers or within outdoor metering cabinets, these instrument transformers provide accurate voltage and current signals for revenue metering and system monitoring applications.
The silicon rubber insulation makes these transformers especially suitable for coastal power distribution systems exposed to salt spray, industrial areas with chemical pollutants, and tropical regions with high humidity and UV exposure. The self-cleaning surface characteristics reduce maintenance requirements and ensure long-term insulation performance.
Main Applications
- Coastal power distribution networks and maritime facilities
- Heavy industrial areas and chemical/petrochemical plants
- Tropical and subtropical regions with high UV radiation
- 6kV/10kV outdoor medium-voltage distribution systems
- High-altitude substations up to 4500m elevation
- Industrial power monitoring and low-maintenance metering solutions
- Mining operations in remote locations
Application Case Studies
Application Scenario 1: Coastal Power Distribution
Coastal power distribution networks face continuous salt spray exposure from ocean environments. Traditional epoxy resin transformers experience rapid surface degradation and flashover incidents in these conditions. Silicon rubber insulation’s hydrophobic properties prevent salt accumulation, maintaining insulation resistance during storms and high-wind events. The self-cleaning surface reduces maintenance frequency and extends service life in marine environments.
Application Scenario 2: Chemical Processing Facilities
Petrochemical and chemical processing plants contain corrosive chemical vapors and airborne particulates that degrade conventional insulation materials. Silicon rubber transformers demonstrate excellent chemical resistance, with rainfall effectively washing away chemical deposits from the surface. The integrated CT and PT design simplifies installation in space-constrained metering cabinets while maintaining billing accuracy for high-consumption industrial operations.
Application Fit
Suitable For
- Coastal and marine environments with salt spray exposure
- Heavy industrial areas and chemical/petrochemical plants
- Tropical regions with high UV radiation and sandstorms
- 6kV/10kV medium voltage outdoor metering applications
- High-altitude installations up to 4500m without derating
- Applications requiring low-maintenance and self-cleaning insulation
- Mining operations in remote or harsh environments
Not Recommended For
- Indoor installations where silicon rubber properties are unnecessary
- Applications requiring separate CT and VT installation
- Protection-only applications where metering accuracy is not required
- Systems above 12kV class without technical confirmation
- Environments with extreme mechanical stress or impact risk
- Applications requiring oil-immersed transformer design
- Projects where installation space cannot accommodate 92kg weight
- Low-pollution indoor environments where cost optimization is priority
Installation Conditions
- Installation position: Outdoor pole-mounted, platform-mounted, or within metering cabinets
- Ambient temperature: -15°C to +55°C
- Maximum altitude: ≤ 4500m (no derating required)
- Pollution level: Suitable for pollution level III and IV areas with heavy contamination
- Grounding: Connect grounding terminal per local electrical codes
- Maintenance: Minimal maintenance required due to self-cleaning hydrophobic surface
Model Variants
The JLSZV(F) series is available in two voltage ratings:
- JLSZV(F)-6W: Designed for 6kV medium voltage systems with insulation level 7.2/32/60kV. Suitable for industrial distribution networks, mining operations, and smaller utility systems operating at 6kV nominal voltage.
- JLSZV(F)-10W: Designed for 10kV medium voltage systems with insulation level 12/42/75kV. Suitable for utility distribution networks, large industrial facilities, and coastal power systems operating at 10kV nominal voltage.
Both models feature silicon rubber insulation technology and are available with multiple accuracy class options for CT and PT outputs. The (F) designation indicates the silicon rubber insulation variant.
Technical Parameters
The JLSZV(F)-6/10W is an outdoor silicon rubber combined instrument transformer for 6kV and 10kV metering in polluted and coastal environments. Operating temperature -15°C to +55°C, altitude up to 4500m, compliant with GB20840.3-2013.
Voltage Transformer Data
| Model | Ratio (V) | Insulation Level (kV) | Accuracy Classes & Burden | Limit Output |
|---|---|---|---|---|
| JLSZV(F)-6W | 6000/100 | 7.2/32/60 | 0.2 (2×20VA), 0.5 (2×50VA), 1.0 (2×80VA), 3.0 (2×200VA) | 2×400 VA |
| JLSZV(F)-10W | 10000/100 | 12/42/75 | 0.2 (2×20VA), 0.5 (2×50VA), 1.0 (2×80VA), 3.0 (2×200VA) | 2×400 VA |
Current Transformer Data
| Parameter | Range / Value |
|---|---|
| Primary Current (Ip) | 7.5A – 600A (selectable ratios) |
| Secondary Current | 5A (standard) |
| Short-Time Thermal Current (1s) | Varies by primary current rating |
| Dynamic Withstand Current | Varies by primary current rating |
Installation & Dimensions
Dimension Reference
| Item | Reference Value |
|---|---|
| Overall width | 895mm |
| Overall height | 582mm |
| Base dimensions | 618mm x 408mm |
| Mounting hole spacing | Per installation drawing |
| Terminal spacing | Per installation drawing |
| Primary terminal type | Bolted connection |
| Secondary terminal box | Sealed enclosure with IP54 protection |
| Approximate weight | 92kg |
![]()
Wiring Diagram
![]()
Installation Guidelines
Mount the silicon rubber combined transformer on a stable platform or pole using the provided mounting brackets. Ensure adequate clearance from grounded surfaces per medium voltage installation standards. Connect primary conductors to the designated terminals (AP1, AP2 for phase A; CP1, CP2 for phase C). Connect secondary wiring to the terminal box, separating metering and protection circuits as required. Ground the transformer frame and secondary circuits per local electrical codes. The silicon rubber insulation requires no special handling precautions during installation.
Standards Compliance
This silicon rubber combined transformer complies with:
- GB20840.3-2013: Instrument transformers – Part 3: Additional requirements for protective voltage transformers
- IEC 61869 series (by reference)
Designed and tested for outdoor use in pollution level III and IV environments. Silicon rubber insulation meets UV resistance and tracking resistance requirements for long-term outdoor exposure.
Selection Guide
When selecting a JLSZV(F) silicon rubber combined transformer:
- Choose JLSZV(F)-6W for 6kV systems or JLSZV(F)-10W for 10kV systems.
- Confirm the installation environment requires silicon rubber insulation (coastal, industrial, high-pollution areas).
- Specify primary current (e.g., 100A, 200A, 400A) based on expected load current.
- Select CT accuracy class: 0.2S for revenue metering, 0.5S for monitoring, 0.5 for general indication.
- Select PT accuracy class: 0.2 for revenue metering, 0.5 for monitoring, 1.0 or 3.0 for indication.
- Confirm altitude does not exceed 4500m.
- Verify installation space can accommodate 895mm x 582mm dimensions and 92kg weight.
Ordering Information
Provide the following when ordering:
- Full model number (JLSZV(F)-6W or JLSZV(F)-10W)
- System voltage (6kV or 10kV)
- CT primary current rating (e.g., 100A, 200A, 400A)
- CT accuracy class (0.2S, 0.5S, or 0.5)
- PT accuracy class (0.2, 0.5, 1.0, or 3.0)
- Rated burden for each accuracy class
- Installation environment description (coastal, industrial, etc.)
- Altitude above sea level
- Quantity required
- Any special requirements (terminal arrangement, painting, etc.)