Product Overview
The ZN63 (VS1)-12 is a three-phase AC 50 Hz indoor high-voltage vacuum circuit breaker rated 12 kV, designed for protection and frequent switching in metal-clad switchgear such as KYN28A-12. Rated currents span 630 A to 3150 A with short-circuit breaking capacities from 20 kA to 50 kA, covering distribution, transformer and motor feeders in industrial plants, mining power networks and substations.
Product Display


Model Designation

Model format: ZN 63 − 12 / □ − □
- Z — Vacuum circuit breaker
- N — Indoor installation
- 63 — Design sequence number
- 12 — Rated voltage (kV)
- First □ — Rated current (A)
- Second □ — Rated short-circuit breaking current (kA)
Service Conditions
- Ambient temperature: −10 °C to +40 °C (storage and transport permitted down to −30 °C)
- Altitude: not exceeding 1000 m above sea level
- Relative humidity: daily average ≤ 95%, monthly average ≤ 90%
- Seismic intensity: not exceeding degree 8
- Installation site free from fire, explosion risk, severe dust, chemical corrosion and intense vibration
- Special service conditions: custom environmental adaptations available on request
Construction
The vacuum interrupter is housed in an APG cast insulating pole with reinforced ribs and skirt edges, which shields it from dust and moisture and provides maintenance-free, stable insulation in polluted indoor environments. The integrated VET spring-charged mechanism supports electric and manual operation, with linkage transmission and buffered damping that limit contact bounce and rebound over a 10,000-operation mechanical life.
Primary terminals are marked P1 (source side) and P2 (load side); secondary circuits provide S1/S2 shunt-trip coils, H1/H2 closing coils and 52a/52b auxiliary contacts for status indication and interlocking.
Technical Data
| Item | Unit | 20kA | 25kA | 31.5kA | 40kA | 50kA |
|---|---|---|---|---|---|---|
| Rated Voltage | kV | 12 | 12 | 12 | 12 | 12 |
| Rated Current | A | 630 | 1250 | 1250 1600 2000 2500 |
1250 1600 2500 3150 |
1250 2500 3150 |
| Rated Short-Circuit Breaking Current | kA | 20 | 25 | 31.5 | 40 | 50 |
| Rated Short-Circuit Making Current (Peak) | kA | 50 | 63 | 80 | 100 | 125 |
| Rated Short-Time Withstand Current (4 s) | kA | 20 | 25 | 31.5 | 40 | 50 |
| Power Frequency Withstand Voltage (across isolating gap) | kV | 48 | 48 | 48 | 48 | 48 |
| Power Frequency Withstand Voltage (closed position) | kV | 42 | 42 | 42 | 42 | 42 |
| Lightning Impulse Withstand Voltage (across isolating gap) | kV | 85 | 85 | 85 | 85 | 85 |
| Lightning Impulse Withstand Voltage (closed position) | kV | 75 | 75 | 75 | 75 | 75 |
| Mechanical Life | Operations | 10000 | 10000 | 10000 | 10000 | 10000 |
| Operating Mechanism Control Voltage | V | AC/DC 110, 220 | ||||
| Contact Opening Distance | mm | 11 ± 1 | ||||
Standards
Manufactured and type-tested in accordance with IEC and GB standards for AC high-voltage circuit breakers, including IEC 62271-100, GB 1984 and GB/T 11022.
Installation & Dimensions
Installation Diagram




The ZN63 (VS1)-12 is available in fixed and withdrawable (handcart) versions for standard switchgear cubicles. The installation requirements are a contact meshing depth of at least 15 mm and a handcart stroke of 200 ± 2 mm, with adequate clearance left for operation and maintenance access.
| Dimension | Value (mm) |
|---|---|
| Handcart Stroke | 200 ± 2 |
| Minimum Contact Meshing Depth | ≥ 15 |
| Rated Current (A) | 630 | 1250 | 1600 |
|---|---|---|---|
| Rated Short-Circuit Breaking Current (kA) | 20, 25 | 25, 31.5, 40 | 31.5 |
| Matched Static Contact Size (mm) | φ35 | φ49 | φ55 |