LJW-10, LJWD-12, 13.8kV Oil-Immersed Steel-Enclosed Outdoor Current Transformer

LJW-10, LJWD-12, 13.8kV Oil-Immersed Steel-Enclosed Outdoor Current Transformer

10kV oil-immersed outdoor current transformer

  • Fully enclosed steel tank for outdoor protection and insulation
  • 10kV system, 50Hz, high accuracy metering and protection
  • Multi-ratio options with primary/secondary taps
  • 1A or 5A secondary output for meters and relays
  • Multiple cores supporting metering and protection functions

Product Overview

The LJW-10 oil-immersed, steel-enclosed outdoor current transformer is designed for 10kV power systems operating at 50Hz. It provides accurate current measurement, energy metering, and relay protection in outdoor switchgear environments. The elliptical oil tank and steel enclosure offer robust insulation and mechanical protection.

Product Type

Item Specification
Product name Oil-immersed, steel-enclosed outdoor current transformer
Model series LJW-10, LJWD-12, LJW-13.8kV
Structure Elliptical oil tank, steel enclosure, ring-type cores with secondary windings
Voltage class 10kV
Rated frequency 50Hz
Secondary current 1A or 5A
Installation Outdoor
Applications Current measurement, energy metering, feeder monitoring, relay protection

Product Display

LJW-10, LJWD-12, 13.8kV Oil-Immersed Steel-Enclosed Outdoor Current Transformer Product Display

Features

  • Oil-immersed with 25# transformer oil for insulation
  • Multiple secondary windings per ring-type core for metering and protection
  • Multi-ratio options and primary/secondary tap configurations
  • Robust steel enclosure for outdoor installation
  • High accuracy classes: 0.2S, 0.5S, 0.2, 0.5, 1.0 for metering; 5P10, 10P20 for protectio

Model Designation

LJW-10, LJWD-12, 13.8kV Oil-Immersed Steel-Enclosed Outdoor Current Transformer Installation and Dimensions

  • Outdoor location, -25°C to +40°C, humidity ≤85%
  • Altitude ≤4000m
  • Primary terminals marked P1/P2, secondary terminals S1/S2
  • Do not open secondary circuit when energized

Installation

LJW-10, LJWD-12, 13.8kV Oil-Immersed Steel-Enclosed Outdoor Current Transformer Installation and Dimensions

Selection Table

Rated

Current

Ratio (A)

Accuracy

Class

Combination

Rated

Output

(VA)

FS ALF 1s Short-Time

Thermal

Current

Rated

Dynamic

Current

150/1 5P10, 10P20 10VA 5 10 150×I1n 375×I1n
200/1 5P10, 10P20 10VA 5 10 180×I1n 400×I1n
300/1 5P10, 10P20 15VA 5 10 200×I1n 450×I1n

FAQs

For current measurement, energy metering, and relay protection in outdoor 10kV systems.

Select rated current 70%-90% of expected operating current to ensure measurement and protection accuracy.

Metering: 0.2S, 0.5S, 0.2, 0.5, 1.0; Protection: 5P10, 10P20.

Through primary or secondary tap structures; each core can support multiple secondary windings.

Outdoor, -25°C to +40°C, humidity ≤85%, altitude ≤4000m, free from corrosive gases.

Do not open secondary circuit under primary voltage; check polarity and grounding.

Yes, each secondary winding can be configured for metering or protection according to project requirements.