Mahsulotga umumiy ko’rib chiqish
LXK-φ80/φ100/φ120/φ150/φ180/φ200/φ240/φ260 bo’linadigan yadroli nol ketma-ketligidagi tok transformatori — kabel yer xatosi himoyasi, qoldiq tokni aniqlash va yerlov xatosini kuzatish uchun mo’ljallangan ichki epoksidli quyilgan yadro muvozanatli tok transformatoridir. Ushbu seriya 50 Hz yoki 60 Hz nominal chastotali ichki AC taqsimlash tizimlarida ishlatiladi hamda to’g’ri kabel izolyatsiyasi va himoya sxemasi bilan birga 35 kV gacha bo’lgan kichik tokli yerlov tizimlari va kabel liniyasi himoyasi dasturlari uchun mos keladi.
Ushbu LXK seriyasi ochiladigan / bo’linadigan yadroli versiyadir. Transformator tanasini ochish, mavjud kabel guruhini atrofida o’rnatish, so’ngra siqish tasmasi yordamida yopib mahkamlash mumkin. Butun (bo’linmagan) nol ketma-ketligidagi tok transformatoriga qaraganda, bo’linadigan yadroli LXK konstruktsiyasi yangilash loyihalari, o’rnatilgan kommutatsion jihozlar, kabel chiqish kameralari hamda kabelni uzish yoki yopiq halq orqali o’tkazish mumkin bo’lmaydigan ta’mirlash almashtirishlari uchun yanada mos keladi.
Mahsulot turi
| Element | Tavsif |
|---|---|
| Mahsulot nomi | LXK-φ80/φ100/φ120/φ150/φ180/φ200/φ240/φ260 Bo’linadigan yadroli nol ketma-ketligidagi tok transformatori |
| Model seriyasi | LXK-80, LXK-100, LXK-120, LXK-150, LXK-180, LXK-200, LXK-240, LXK-260 |
| Mahsulot konstruktsiyasi | Ichki epoksidli quyilgan bo’linadigan yadroli / ochiladigan nol ketma-ketligidagi tok transformatori |
| Ichki diametr variantlari | φ80, φ100, φ120, φ150, φ180, φ200, φ240, φ260 |
| Nominal izolyatsiya darajasi | 0,72/3 kV |
| Nominal chastota | 50 Hz / 60 Hz |
| Nominal ikkilamchi tok | 5 A yoki 1 A |
| Himoya klassi | Tanlangan model va nisbatga qarab 10P5, 10P10, 10P15, 10P20 |
| O’rnatish joyi | Ichki |
| Odatiy dasturlar | Kabel yer xatosi himoyasi, nol ketma-ketligidagi tokni aniqlash, qoldiq tokni kuzatish, rele himoyasi kirish signali |
Mahsulot namoyishi


Asosiy dasturlar
- Kichik tokli yerlov tizimlari uchun ichki kabel yer xatosi himoyasi
- Uch fazali kabel liniyasi zanjirlarida nol ketma-ketligidagi tokni aniqlash
- Kommutatsion jihozlar, halqa tarmoq shkafchalari va himoya panelida qoldiq tokni kuzatish
- Yerlov xatosi ogohlantiruvchi va o’tkazgichni uzuvchi himoya zanjirlari
- Kabel boshlig’ini olib tashlamasdan mavjud kabel atrofida yangilash o’rnatish
- Elektrodvigatel liniyasi, generator liniyasi, kabel filiali va taqsimlash liniyasi himoyasi
- 5 A yoki 1 A ikkilamchi tok kirishini talab qiluvchi rele himoya tizimlari
Asosiy texnik xususiyatlar
- Bo’linadigan yadroli ochiladigan tuzilma: Transformator mavjud kabel atrofida ochilib o’rnatilishi mumkin, bu o’rnatish ishlarini kamaytiradi va kabelni uzishni talab qilmaydi.
- Ichki diametri aniq belgilangan: φ80 dan φ260 gacha bo’lgan teshiklar turli kabel guruhlarining hajmini qamrab oladi; model nomi tanlangan ichki diametrni o’z ichiga oladi.
- Epoksidli quyilgan izolyatsiya: Yadro va o’ram epoksid smola bilan quyilgan bo’lib, izolyatsiya xususiyatlari, namlikka chidamlilik va mexanik barqarorlikni ta’minlaydi.
- Nol ketma-ketligini aniqlash: Izolyatsiya xatolari yoki bitta fazali yerlov xatolaridan hosil bo’lgan qoldiq tokni aniqlaydi.
- Himoya relesi chiqishi: Rele himoyasi, kuzatish va ogohlantirish tizimlari uchun 5 A yoki 1 A ikkilamchi tok signallarini ta’minlaydi.
- 10P himoya klasslari: Model hajmi, tok nisbati va nominal yuklamaga qarab 10P5 dan 10P20 gacha variantlar mavjud.
Ish prinsipi
LXK bo’linadigan yadroli nol ketma-ketligidagi tok transformatori uning teshigidan o’tayotgan barcha fazaviy toklarning vektor yig’indisini o’lchaydi. Oddiy muvozanatlangan ishlash sharoitida uch fazali toklarning yig’indisi nolga yaqin bo’ladi. Yerlov xatosi, izolyatsiya xatosi yoki oqish sodir bo’lganda muvozanat buziladi va nol ketma-ketligidagi tok paydo bo’ladi. Tok transformatori qoldiq tokni ulangan rele yoki kuzatish qurilmasi uchun ikkilamchi signalga aylantiradi.
To’g’ri himoya uchun himoyalangan barcha fazaviy o’tkazgichlar bir xil yo’nalishda bir xil teshikdan o’tishi kerak. Kabel ekran, zirh, neytral va PE o’tkazgichlarining yo’naltirilishi himoya sxemasiga mos kelishi kerak. Noto’g’ri yo’naltirish qoldiq tok signalini bekor qilishi yoki buzishi mumkin.
Model belgilash

LXK model kodi quyidagicha izohlanadi:
| Kod | Ma’nosi |
|---|---|
| L | Tok transformatori |
| X | Nol ketma-ketligi / qoldiq tokni aniqlash |
| K | Ushbu mahsulot seriyasidagi ochiladigan / bo’linadigan yadroli tuzilma |
| 80 / 100 / 120 / 150 / 180 / 200 / 240 / 260 | Millimetrda nominal teshik diametri |
| O’lcham guruhi, masalan, 120/204×57 | Ichki diametr / tashqi diametr × tananing qalinligi ma’lumotnomasi |
Tuzilma tavsifi
LXK ochiladigan nol ketma-ketligidagi tok transformatori ikkita epoksidli quyilgan yarim halqadan iborat. O’rnatish paytida nerjaveyka po’lat siqish tasmasi yoki mahkamlash mexanizmi bo’shatiladi, ikkala bo’lak kabel guruhini atrofida joylashtiriladi va yadro to’liq magnit yo’lga yopiladi. Yopgandan so’ng siqish tasmasi yadro tutash sirtlari orasida to’liq aloqani ta’minlash uchun tekis tortiladi.
Ushbu bo’linadigan yadroli tuzilma ayniqsa mavjud kabel tizimlari uchun foydalidir. U kabelni kesish, kabel boshlig’ini olib tashlash yoki asosiy o’tkazgich yo’nalishini o’zgartirmasdan nol ketma-ketligi himoyasini qo’shish yoki almashtirish imkonini beradi. Epoksidli quyilgan tanasi ikkilamchi o’ram va magnit yadroni himoya qiladi, asosiy birlamchi izolyatsiyani esa o’zi kabel ta’minlaydi.
Texnik ma’lumotlar
| Element | Tavsif |
|---|---|
| Model seriyasi | LXK-80 dan LXK-260 gacha bo’linadigan yadroli turi |
| Mahsulot turi | Ichki epoksidli quyilgan bo’linadigan yadroli nol ketma-ketligidagi tok transformatori |
| Qo’llaniladigan tizim | 35 kV gacha bo’lgan ichki kichik tokli yerlov tizimlari va kabel liniyasi himoyasi tizimlari |
| Nominal izolyatsiya darajasi | 0,72/3 kV |
| Nominal chastota | 50 Hz / 60 Hz |
| Nominal ikkilamchi tok | 5 A yoki 1 A |
| Himoya klassi | Tanlangan modelga qarab 10P5, 10P10, 10P15, 10P20 |
| Nominal chiqish | Teshik hajmi, tok nisbati va himoya klassiga qarab 1 VA dan 15 VA gacha |
| Atrof-muhit harorati | -25°C dan +40°C gacha |
| Ikkilamchi o’ramning chidamli kuchlanishi | 3 kV sanoat chastotali chidamli kuchlanish, texnik kelishuvga bog’liq |
| Qo’llaniladigan standartlar | GB/T 20840.1-2010, GB/T 20840.2-2014; IEC 61869-1 va IEC 61869-2 ma’lumotnomasi |
Seriyali teshik va model ma’lumotnomasi
| Model | Ichki
Diametr |
Odatiy
O’lcham kodi |
Himoya klassi
Oraliq |
Odatiy nominal
Chiqish oraliq |
Tanlash
Foydalanish |
|---|---|---|---|---|---|
| LXK-80 | φ80 mm | 80/165×57 | 10P5 dan 10P10 gacha | 5 VA dan 2,5 VA gacha | Kichik kabel guruhlari va tor shkaf maydoni |
| LXK-100 | φ100 mm | 100/180×55, 100/180×57 | 10P5 dan 10P10 yoki 10P15 gacha | 5 VA dan 2,5 VA yoki 10 VA dan 2,5 VA gacha | Odatiy kabel liniyasi himoyasi |
| LXK-120 | φ120 mm | 120/204×57, 120/210×65, 120/210×100, 120/250×80 | 10P5 dan 10P20 gacha | 1 VA dan 15 VA gacha | Odatiy halqa tarmoq shkafi va kabel chiqish dasturlari |
| LXK-150 | φ150 mm | 150/235×57, 150/280×80 | 10P5 dan 10P20 gacha | 10 VA dan 2,5 VA yoki 15 VA dan 5 VA gacha | O’rta hajmli kabel guruh himoyasi |
| LXK-180 | φ180 mm | 180/265×57, 180/310×80 | 10P5 dan 10P20 gacha | 10 VA dan 2,5 VA yoki 15 VA dan 5 VA gacha | Katta kabel liniyasi himoyasi |
| LXK-200 | φ200 mm | 200/330×80 | 10P5 dan 10P20 gacha | 15 VA dan 2,5 VA gacha | Yuqori quvvatli kabel guruhlari |
| LXK-240 | φ240 mm | 240/350×80 | 10P5 dan 10P20 gacha | 15 VA dan 5 VA gacha | Katta diametrli kabel guruhlari |
| LXK-260 | φ260 mm | 260/370×80 | 10P5 dan 10P20 gacha | 15 VA dan 1,5 VA gacha yoki ko’rsatilgandek | Ushbu seriyadagi maksimal teshik varianti |
Nominal tok nisbati va chiqish ma’lumotnomasi
| Tok
Nisbati |
Ikkilamchi
Tok |
Odatiy nominal
Chiqish oraliq |
Qo’llaniladigan
Himoya klassi |
|---|---|---|---|
| 50/5 | 5 A | Modelga qarab 5 VA dan 1 VA gacha | 10P5 dan 10P20 gacha |
| 75/5 | 5 A | Modelga qarab 10 VA dan 1 VA gacha | 10P5 dan 10P20 gacha |
| 100/5 | 5 A | Modelga qarab 10 VA dan 2,5 VA gacha | 10P5 dan 10P20 gacha |
| 150/5 | 5 A | Modelga qarab 10 VA dan 5 VA gacha | 10P5 dan 10P20 gacha |
| 200/5 | 5 A | Modelga qarab 15 VA dan 5 VA gacha | 10P5 dan 10P20 gacha |
| 250/5 | 5 A | Modelga qarab 15 VA dan 5 VA gacha | 10P5 dan 10P20 gacha |
| 300/5 | 5 A | Modelga qarab 15 VA dan 2,5 VA gacha | 10P5 dan 10P20 gacha |
| 400/5 | 5 A | Modelga qarab 10 VA dan 2,5 VA gacha | 10P5 dan 10P20 gacha |
| 50/1 dan 250/1 gacha | 1 A | Modelga qarab 5 VA dan 1 VA gacha | 10P5 dan 10P20 gacha |
Eslatma: Aniq nominal chiqish teshik hajmi, yadro kengligi, tok nisbati, ikkilamchi tok va himoya klassiga bog’liq. Katalog oraliqidan tashqari parametrlar texnik kelishuv orqali tasdiqlanishi mumkin.
Xizmat ko’rsatish sharoitlari
- O’rnatish joyi: ichki
- Nominal chastota: 50 Hz / 60 Hz
- Qo’llaniladigan tizim: 35 kV gacha bo’lgan kichik tokli yerlov tizimlari va kabel liniyasi himoyasi tizimlari
- Atrof-muhit harorati: -25°C dan +40°C gacha
- Tavsiya etilgan muhit: kuchli titrash, korroziyaga sababchi gaz, o’tkazuvchan chang, portlovchi muhit, kuchli namlik yoki jiddiy ifloslanish bo’lmasa kerak
- Himoyalangan barcha fazaviy o’tkazgichlar bir xil yo’nalishda bir xil tok transformatori teshigidan o’tishi kerak
- Bo’linadigan yadro aloqa sirti toza bo’lishi va ishga tushirishdan oldin to’liq yopilgan bo’lishi kerak
- Maxsus kabel diametri, rele modeli, sim uzunligi, yuklama yoki sezgirligi talablari bo’lsa, buyurtma berishdan oldin parametrlarni tasdiqlang
Standartlar va moslik
LXK bo’linadigan yadroli nol ketma-ketligidagi tok transformatori seriyasi GB/T 20840.1-2010 va GB/T 20840.2-2014 ga muvofiq ishlab chiqilgan bo’lib, IEC 61869 o’lchov transformatorlari doirasiga mos keladi. Loyiha talablari asosida muntazam sinov elementlari, belgilash, izolyatsiya sinovlari, nisbatni tekshirish va himoya aniqligini tekshirish amalga oshirilishi mumkin.
O’rnatish va o’lchamlar

Model hajmi va o’lcham ma’lumotnomasi
| Model | Turi /
O’lcham kodi |
φd | φD | C | a | b | A | B | E | L | f | h |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LXK-80 | 80/165×57 | 80 | 165 | 57 | 110 | 60 | 130 | 120 | 102 | 185 | 10 | 17 |
| LXK-100 | 100/180×55 | 100 | 177 | 55 | 110 | 90 | 130 | 118 | 114 | 203 | 10 | 17 |
| LXK-100 | 100/180×57 | 100 | 180 | 57 | 110 | 90 | 130 | 120 | 113 | 203 | 10 | 17 |
| LXK-120 | 120/204×57 | 120 | 204 | 57 | 110 | 90 | 130 | 120 | 121 | 223 | 10 | 17 |
| LXK-120 | 120/210×65 | 120 | 210 | 65 | 110 | 100 | 130 | 125 | 123 | 228 | 10 | 17 |
| LXK-120 | 120/210×100 | 120 | 210 | 100 | 110 | 133 | 130 | 163 | 123 | 228 | 13 | 23 |
| LXK-120 | 120/250×80 | 120 | 250 | 80 | 150 | 140 | 190 | 174 | 153 | 268 | 10 | 17 |
| LXK-150 | 150/235×57 | 150 | 235 | 57 | 150 | 125 | 190 | 151 | 150 | 267 | 13 | 23 |
| LXK-150 | 150/280×80 | 150 | 280 | 80 | 150 | 140 | 190 | 174 | 158 | 297 | 13 | 23 |
| LXK-160 | 160/250×80 | 160 | 250 | 80 | 150 | 140 | 190 | 174 | 156 | 290 | 13 | 23 |
| LXK-180 | 180/265×57 | 180 | 265 | 57 | 150 | 125 | 190 | 161 | 165 | 298 | 13 | 23 |
| LXK-180 | 180/310×80 | 180 | 310 | 80 | 220 | 125 | 260 | 164 | 190 | 365 | 13 | 23 |
| LXK-200 | 200/330×80 | 200 | 330 | 80 | 220 | 125 | 260 | 164 | 200 | 365 | 13 | 23 |
| LXK-240 | 240/350×80 | 240 | 350 | 80 | 220 | 125 | 260 | 164 | 220 | 395 | 13 | 23 |
| LXK-260 | 260/370×80 | 260 | 370 | 80 | 220 | 125 | 260 | 164 | 229 | 410 | 13 | 23 |
Birlik: mm. Yakuniy o’lchamlar, siqish tasmasi joylashuvi, terminal qutisi o’rnashuvi va o’rnatish bo’shlig’i tasdiqlangan kontur chizmaga bog’liq.
O’rnatishdan oldin tanlangan teshik kabel guruhini to’liq qamrab olishini va kabel egilish radiusi shkaf tartibiga mos kelishini tasdiqlang. Siqish tasmasini bo’shatib bo’linadigan yadro tanasini oching, transformatorni kabel guruhini atrofida joylashtiring, yadroni yoping va tasmani tekis torting. Tutash sirtlarda bo’shliq, chang, metall zarralar yoki noto’g’ri joylashuv sezgirligi va chiqish barqarorligiga ta’sir qilishi mumkin.
Ulanish va sim tortish eslatmalari
- Barcha fazaviy o’tkazgichlar bir xil yo’nalishda bir xil teshikdan o’tishi kerak.
- Nol ketma-ketligi himoyasi uchun faqat bitta fazaviy o’tkazgich tok transformatoridan o’tkazilmasin.
- Ikkilamchi terminal K1/K2 yoki S1/S2 ni rele sim tortish sxemasi va terminal belgilashiga muvofiq ulang.
- Rele himoya sxemasi yo’nalishli yoki muvofiqlashtirilgan ishlashni talab qilsa, polarlikka e’tibor bering.
- Ikkilamchi zanjirning bitta nuqtasi qo’llaniladigan himoya amaliyotiga muvofiq yerlovga ulanishi kerak.
- Birlamchi zanjir kuchlanish ostida bo’lganda tok transformatorining ikkilamchi zanjiri ochiq zanjir bo’lishi mumkin emas.
- Ishga tushirishdan oldin rele yuklamasini, ikkilamchi kabel uzunligini va terminal ulanishini tekshiring.
O’rnatish va xavfsizlik eslatmalari
- O’rnatishdan oldin model, teshik diametri, tok nisbati, ikkilamchi tok, himoya klassi va nominal chiqishni tasdiqlang.
- Himoya sxemasiga mos keladigan ekran yoki zirh o’tkazgichlari yo’naltirish talablari bilan birga himoyalangan barcha kabelga mos kelishini tekshiring.
- Yadro tutash sirtini toza saqlang va siqish tasmasini tortishdan oldin to’liq aloqani ta’minlang.
- Agar bo’linadigan yadro tanasi to’liq yopilmagan yoki siqish tasmasi bo’sh bo’lsa, tizimni kuchlanish ostiga qo’ymang.
- Transformatorni tasdiqlangan chizmaga muvofiq ichki shkaf yoki kabel kamerasiga o’rnating.
- O’rnatish, sinov va texnik xizmat ko’rsatish malakali elektr mutaxassislari tomonidan amalga oshirilishi kerak.
Tanlash yo’riqnomalari
- Ichki diametrni tasdiqlang: Himoyalangan to’liq kabel guruhining tashqi o’lchamlariga qarab φ80, φ100, φ120, φ150, φ180, φ200, φ240 yoki φ260 ni tanlang.
- Bo’linadigan yadro talabini tasdiqlang: Kabel allaqachon o’rnatilgan yoki uzib bo’lmasa, ochiladigan LXK dan foydalaning.
- Tana qalinligini tasdiqlang: Nominal chiqish talabi va shkaf chuqurligiga qarab 55, 57, 65, 80 yoki 100 mm tuzilmani tanlang.
- Tok nisbatini tasdiqlang: Rele kirishiga, sozlash diapazoniga va xato aniqlash talabiga qarab nisbatni tanlang.
- Ikkilamchi tokni tanlang: Rele yoki kuzatish qurilmasi kirishiga qarab 5 A yoki 1 A ni tanlang.
- Himoya klassini tanlang: Talab qilingan himoya aniqligi va yuklamaga qarab 10P5 dan 10P20 gacha tanlang.
- Sim tortish yuklamasini tekshiring: Rele kirishi, ikkilamchi kabel va terminal yuklamasi nominal chiqishdan oshmasligi kerak.
- O’tkazgich yo’naltirishini tekshiring: Himoya sxemasiga qarab kabel ekran, zirh, neytral yoki PE o’tkazgichi tok transformatoridan o’tishi yoki uning atrofidan o’tishi kerakligini tasdiqlang.