LXK-φ80, φ100, φ120, φ180-φ260 bo’linadigan yadroli nol ketma-ketligidagi tok transformatori

LXK-φ80, φ100, φ120, φ180-φ260 bo’linadigan yadroli nol ketma-ketligidagi tok transformatori

Kabelning yerga ulanish xatosini himoya qilish uchun φ80-φ260 teshikli bo'linadigan yadroli nol ketma-ketligidagi tok transformatorlari

  • LXK-φ80/φ100/φ120/φ150/φ180/φ200/φ240/φ260 bo'linadigan yadroli nol ketma-ketligidagi tok transformatorlar seriyasi
  • Mavjud kabel guruhlariga o'rnatish uchun ochiq turdagi epoksiyli quyish strukturasiga ega
  • Rele va qoldiq tok monitoring kirishlari uchun 5 A yoki 1 A nominal ikkilamchi chiqish
  • 1 VA dan 15 VA gacha quvvat berish imkoniyati bilan 10P5 dan 10P20 gacha himoya sinflari
  • Ichki kabelning yerga ulanish xatosini himoya qilish, yerga ulanish xatosini aniqlash hamda mavjud kommutatsion jihozlarga qo'shimcha o'rnatish uchun mo'ljallangan

Mahsulotga umumiy ko’rib chiqish

LXK-φ80/φ100/φ120/φ150/φ180/φ200/φ240/φ260 bo’linadigan yadroli nol ketma-ketligidagi tok transformatori — kabel yer xatosi himoyasi, qoldiq tokni aniqlash va yerlov xatosini kuzatish uchun mo’ljallangan ichki epoksidli quyilgan yadro muvozanatli tok transformatoridir. Ushbu seriya 50 Hz yoki 60 Hz nominal chastotali ichki AC taqsimlash tizimlarida ishlatiladi hamda to’g’ri kabel izolyatsiyasi va himoya sxemasi bilan birga 35 kV gacha bo’lgan kichik tokli yerlov tizimlari va kabel liniyasi himoyasi dasturlari uchun mos keladi.

Ushbu LXK seriyasi ochiladigan / bo’linadigan yadroli versiyadir. Transformator tanasini ochish, mavjud kabel guruhini atrofida o’rnatish, so’ngra siqish tasmasi yordamida yopib mahkamlash mumkin. Butun (bo’linmagan) nol ketma-ketligidagi tok transformatoriga qaraganda, bo’linadigan yadroli LXK konstruktsiyasi yangilash loyihalari, o’rnatilgan kommutatsion jihozlar, kabel chiqish kameralari hamda kabelni uzish yoki yopiq halq orqali o’tkazish mumkin bo’lmaydigan ta’mirlash almashtirishlari uchun yanada mos keladi.

Mahsulot turi

Element Tavsif
Mahsulot nomi LXK-φ80/φ100/φ120/φ150/φ180/φ200/φ240/φ260 Bo’linadigan yadroli nol ketma-ketligidagi tok transformatori
Model seriyasi LXK-80, LXK-100, LXK-120, LXK-150, LXK-180, LXK-200, LXK-240, LXK-260
Mahsulot konstruktsiyasi Ichki epoksidli quyilgan bo’linadigan yadroli / ochiladigan nol ketma-ketligidagi tok transformatori
Ichki diametr variantlari φ80, φ100, φ120, φ150, φ180, φ200, φ240, φ260
Nominal izolyatsiya darajasi 0,72/3 kV
Nominal chastota 50 Hz / 60 Hz
Nominal ikkilamchi tok 5 A yoki 1 A
Himoya klassi Tanlangan model va nisbatga qarab 10P5, 10P10, 10P15, 10P20
O’rnatish joyi Ichki
Odatiy dasturlar Kabel yer xatosi himoyasi, nol ketma-ketligidagi tokni aniqlash, qoldiq tokni kuzatish, rele himoyasi kirish signali

Mahsulot namoyishi

Mahsulot namoyishi

LXK 80 120

Asosiy dasturlar

  • Kichik tokli yerlov tizimlari uchun ichki kabel yer xatosi himoyasi
  • Uch fazali kabel liniyasi zanjirlarida nol ketma-ketligidagi tokni aniqlash
  • Kommutatsion jihozlar, halqa tarmoq shkafchalari va himoya panelida qoldiq tokni kuzatish
  • Yerlov xatosi ogohlantiruvchi va o’tkazgichni uzuvchi himoya zanjirlari
  • Kabel boshlig’ini olib tashlamasdan mavjud kabel atrofida yangilash o’rnatish
  • Elektrodvigatel liniyasi, generator liniyasi, kabel filiali va taqsimlash liniyasi himoyasi
  • 5 A yoki 1 A ikkilamchi tok kirishini talab qiluvchi rele himoya tizimlari

Asosiy texnik xususiyatlar

  • Bo’linadigan yadroli ochiladigan tuzilma: Transformator mavjud kabel atrofida ochilib o’rnatilishi mumkin, bu o’rnatish ishlarini kamaytiradi va kabelni uzishni talab qilmaydi.
  • Ichki diametri aniq belgilangan: φ80 dan φ260 gacha bo’lgan teshiklar turli kabel guruhlarining hajmini qamrab oladi; model nomi tanlangan ichki diametrni o’z ichiga oladi.
  • Epoksidli quyilgan izolyatsiya: Yadro va o’ram epoksid smola bilan quyilgan bo’lib, izolyatsiya xususiyatlari, namlikka chidamlilik va mexanik barqarorlikni ta’minlaydi.
  • Nol ketma-ketligini aniqlash: Izolyatsiya xatolari yoki bitta fazali yerlov xatolaridan hosil bo’lgan qoldiq tokni aniqlaydi.
  • Himoya relesi chiqishi: Rele himoyasi, kuzatish va ogohlantirish tizimlari uchun 5 A yoki 1 A ikkilamchi tok signallarini ta’minlaydi.
  • 10P himoya klasslari: Model hajmi, tok nisbati va nominal yuklamaga qarab 10P5 dan 10P20 gacha variantlar mavjud.

Ish prinsipi

LXK bo’linadigan yadroli nol ketma-ketligidagi tok transformatori uning teshigidan o’tayotgan barcha fazaviy toklarning vektor yig’indisini o’lchaydi. Oddiy muvozanatlangan ishlash sharoitida uch fazali toklarning yig’indisi nolga yaqin bo’ladi. Yerlov xatosi, izolyatsiya xatosi yoki oqish sodir bo’lganda muvozanat buziladi va nol ketma-ketligidagi tok paydo bo’ladi. Tok transformatori qoldiq tokni ulangan rele yoki kuzatish qurilmasi uchun ikkilamchi signalga aylantiradi.

To’g’ri himoya uchun himoyalangan barcha fazaviy o’tkazgichlar bir xil yo’nalishda bir xil teshikdan o’tishi kerak. Kabel ekran, zirh, neytral va PE o’tkazgichlarining yo’naltirilishi himoya sxemasiga mos kelishi kerak. Noto’g’ri yo’naltirish qoldiq tok signalini bekor qilishi yoki buzishi mumkin.

Model belgilash

Model belgilash

LXK model kodi quyidagicha izohlanadi:

Kod Ma’nosi
L Tok transformatori
X Nol ketma-ketligi / qoldiq tokni aniqlash
K Ushbu mahsulot seriyasidagi ochiladigan / bo’linadigan yadroli tuzilma
80 / 100 / 120 / 150 / 180 / 200 / 240 / 260 Millimetrda nominal teshik diametri
O’lcham guruhi, masalan, 120/204×57 Ichki diametr / tashqi diametr × tananing qalinligi ma’lumotnomasi

Tuzilma tavsifi

LXK ochiladigan nol ketma-ketligidagi tok transformatori ikkita epoksidli quyilgan yarim halqadan iborat. O’rnatish paytida nerjaveyka po’lat siqish tasmasi yoki mahkamlash mexanizmi bo’shatiladi, ikkala bo’lak kabel guruhini atrofida joylashtiriladi va yadro to’liq magnit yo’lga yopiladi. Yopgandan so’ng siqish tasmasi yadro tutash sirtlari orasida to’liq aloqani ta’minlash uchun tekis tortiladi.

Ushbu bo’linadigan yadroli tuzilma ayniqsa mavjud kabel tizimlari uchun foydalidir. U kabelni kesish, kabel boshlig’ini olib tashlash yoki asosiy o’tkazgich yo’nalishini o’zgartirmasdan nol ketma-ketligi himoyasini qo’shish yoki almashtirish imkonini beradi. Epoksidli quyilgan tanasi ikkilamchi o’ram va magnit yadroni himoya qiladi, asosiy birlamchi izolyatsiyani esa o’zi kabel ta’minlaydi.

Texnik ma’lumotlar

Element Tavsif
Model seriyasi LXK-80 dan LXK-260 gacha bo’linadigan yadroli turi
Mahsulot turi Ichki epoksidli quyilgan bo’linadigan yadroli nol ketma-ketligidagi tok transformatori
Qo’llaniladigan tizim 35 kV gacha bo’lgan ichki kichik tokli yerlov tizimlari va kabel liniyasi himoyasi tizimlari
Nominal izolyatsiya darajasi 0,72/3 kV
Nominal chastota 50 Hz / 60 Hz
Nominal ikkilamchi tok 5 A yoki 1 A
Himoya klassi Tanlangan modelga qarab 10P5, 10P10, 10P15, 10P20
Nominal chiqish Teshik hajmi, tok nisbati va himoya klassiga qarab 1 VA dan 15 VA gacha
Atrof-muhit harorati -25°C dan +40°C gacha
Ikkilamchi o’ramning chidamli kuchlanishi 3 kV sanoat chastotali chidamli kuchlanish, texnik kelishuvga bog’liq
Qo’llaniladigan standartlar GB/T 20840.1-2010, GB/T 20840.2-2014; IEC 61869-1 va IEC 61869-2 ma’lumotnomasi

Seriyali teshik va model ma’lumotnomasi

Model Ichki

Diametr

Odatiy

O’lcham kodi

Himoya klassi

Oraliq

Odatiy nominal

Chiqish oraliq

Tanlash

Foydalanish

LXK-80 φ80 mm 80/165×57 10P5 dan 10P10 gacha 5 VA dan 2,5 VA gacha Kichik kabel guruhlari va tor shkaf maydoni
LXK-100 φ100 mm 100/180×55, 100/180×57 10P5 dan 10P10 yoki 10P15 gacha 5 VA dan 2,5 VA yoki 10 VA dan 2,5 VA gacha Odatiy kabel liniyasi himoyasi
LXK-120 φ120 mm 120/204×57, 120/210×65, 120/210×100, 120/250×80 10P5 dan 10P20 gacha 1 VA dan 15 VA gacha Odatiy halqa tarmoq shkafi va kabel chiqish dasturlari
LXK-150 φ150 mm 150/235×57, 150/280×80 10P5 dan 10P20 gacha 10 VA dan 2,5 VA yoki 15 VA dan 5 VA gacha O’rta hajmli kabel guruh himoyasi
LXK-180 φ180 mm 180/265×57, 180/310×80 10P5 dan 10P20 gacha 10 VA dan 2,5 VA yoki 15 VA dan 5 VA gacha Katta kabel liniyasi himoyasi
LXK-200 φ200 mm 200/330×80 10P5 dan 10P20 gacha 15 VA dan 2,5 VA gacha Yuqori quvvatli kabel guruhlari
LXK-240 φ240 mm 240/350×80 10P5 dan 10P20 gacha 15 VA dan 5 VA gacha Katta diametrli kabel guruhlari
LXK-260 φ260 mm 260/370×80 10P5 dan 10P20 gacha 15 VA dan 1,5 VA gacha yoki ko’rsatilgandek Ushbu seriyadagi maksimal teshik varianti

Nominal tok nisbati va chiqish ma’lumotnomasi

Tok

Nisbati

Ikkilamchi

Tok

Odatiy nominal

Chiqish oraliq

Qo’llaniladigan

Himoya klassi

50/5 5 A Modelga qarab 5 VA dan 1 VA gacha 10P5 dan 10P20 gacha
75/5 5 A Modelga qarab 10 VA dan 1 VA gacha 10P5 dan 10P20 gacha
100/5 5 A Modelga qarab 10 VA dan 2,5 VA gacha 10P5 dan 10P20 gacha
150/5 5 A Modelga qarab 10 VA dan 5 VA gacha 10P5 dan 10P20 gacha
200/5 5 A Modelga qarab 15 VA dan 5 VA gacha 10P5 dan 10P20 gacha
250/5 5 A Modelga qarab 15 VA dan 5 VA gacha 10P5 dan 10P20 gacha
300/5 5 A Modelga qarab 15 VA dan 2,5 VA gacha 10P5 dan 10P20 gacha
400/5 5 A Modelga qarab 10 VA dan 2,5 VA gacha 10P5 dan 10P20 gacha
50/1 dan 250/1 gacha 1 A Modelga qarab 5 VA dan 1 VA gacha 10P5 dan 10P20 gacha

Eslatma: Aniq nominal chiqish teshik hajmi, yadro kengligi, tok nisbati, ikkilamchi tok va himoya klassiga bog’liq. Katalog oraliqidan tashqari parametrlar texnik kelishuv orqali tasdiqlanishi mumkin.

Xizmat ko’rsatish sharoitlari

  • O’rnatish joyi: ichki
  • Nominal chastota: 50 Hz / 60 Hz
  • Qo’llaniladigan tizim: 35 kV gacha bo’lgan kichik tokli yerlov tizimlari va kabel liniyasi himoyasi tizimlari
  • Atrof-muhit harorati: -25°C dan +40°C gacha
  • Tavsiya etilgan muhit: kuchli titrash, korroziyaga sababchi gaz, o’tkazuvchan chang, portlovchi muhit, kuchli namlik yoki jiddiy ifloslanish bo’lmasa kerak
  • Himoyalangan barcha fazaviy o’tkazgichlar bir xil yo’nalishda bir xil tok transformatori teshigidan o’tishi kerak
  • Bo’linadigan yadro aloqa sirti toza bo’lishi va ishga tushirishdan oldin to’liq yopilgan bo’lishi kerak
  • Maxsus kabel diametri, rele modeli, sim uzunligi, yuklama yoki sezgirligi talablari bo’lsa, buyurtma berishdan oldin parametrlarni tasdiqlang

Standartlar va moslik

LXK bo’linadigan yadroli nol ketma-ketligidagi tok transformatori seriyasi GB/T 20840.1-2010 va GB/T 20840.2-2014 ga muvofiq ishlab chiqilgan bo’lib, IEC 61869 o’lchov transformatorlari doirasiga mos keladi. Loyiha talablari asosida muntazam sinov elementlari, belgilash, izolyatsiya sinovlari, nisbatni tekshirish va himoya aniqligini tekshirish amalga oshirilishi mumkin.

O’rnatish va o’lchamlar

LXK 120 open type ct installlation size

Model hajmi va o’lcham ma’lumotnomasi

Model Turi /

O’lcham kodi

φd φD C a b A B E L f h
LXK-80 80/165×57 80 165 57 110 60 130 120 102 185 10 17
LXK-100 100/180×55 100 177 55 110 90 130 118 114 203 10 17
LXK-100 100/180×57 100 180 57 110 90 130 120 113 203 10 17
LXK-120 120/204×57 120 204 57 110 90 130 120 121 223 10 17
LXK-120 120/210×65 120 210 65 110 100 130 125 123 228 10 17
LXK-120 120/210×100 120 210 100 110 133 130 163 123 228 13 23
LXK-120 120/250×80 120 250 80 150 140 190 174 153 268 10 17
LXK-150 150/235×57 150 235 57 150 125 190 151 150 267 13 23
LXK-150 150/280×80 150 280 80 150 140 190 174 158 297 13 23
LXK-160 160/250×80 160 250 80 150 140 190 174 156 290 13 23
LXK-180 180/265×57 180 265 57 150 125 190 161 165 298 13 23
LXK-180 180/310×80 180 310 80 220 125 260 164 190 365 13 23
LXK-200 200/330×80 200 330 80 220 125 260 164 200 365 13 23
LXK-240 240/350×80 240 350 80 220 125 260 164 220 395 13 23
LXK-260 260/370×80 260 370 80 220 125 260 164 229 410 13 23

Birlik: mm. Yakuniy o’lchamlar, siqish tasmasi joylashuvi, terminal qutisi o’rnashuvi va o’rnatish bo’shlig’i tasdiqlangan kontur chizmaga bog’liq.

O’rnatishdan oldin tanlangan teshik kabel guruhini to’liq qamrab olishini va kabel egilish radiusi shkaf tartibiga mos kelishini tasdiqlang. Siqish tasmasini bo’shatib bo’linadigan yadro tanasini oching, transformatorni kabel guruhini atrofida joylashtiring, yadroni yoping va tasmani tekis torting. Tutash sirtlarda bo’shliq, chang, metall zarralar yoki noto’g’ri joylashuv sezgirligi va chiqish barqarorligiga ta’sir qilishi mumkin.

Ulanish va sim tortish eslatmalari

  • Barcha fazaviy o’tkazgichlar bir xil yo’nalishda bir xil teshikdan o’tishi kerak.
  • Nol ketma-ketligi himoyasi uchun faqat bitta fazaviy o’tkazgich tok transformatoridan o’tkazilmasin.
  • Ikkilamchi terminal K1/K2 yoki S1/S2 ni rele sim tortish sxemasi va terminal belgilashiga muvofiq ulang.
  • Rele himoya sxemasi yo’nalishli yoki muvofiqlashtirilgan ishlashni talab qilsa, polarlikka e’tibor bering.
  • Ikkilamchi zanjirning bitta nuqtasi qo’llaniladigan himoya amaliyotiga muvofiq yerlovga ulanishi kerak.
  • Birlamchi zanjir kuchlanish ostida bo’lganda tok transformatorining ikkilamchi zanjiri ochiq zanjir bo’lishi mumkin emas.
  • Ishga tushirishdan oldin rele yuklamasini, ikkilamchi kabel uzunligini va terminal ulanishini tekshiring.

O’rnatish va xavfsizlik eslatmalari

  • O’rnatishdan oldin model, teshik diametri, tok nisbati, ikkilamchi tok, himoya klassi va nominal chiqishni tasdiqlang.
  • Himoya sxemasiga mos keladigan ekran yoki zirh o’tkazgichlari yo’naltirish talablari bilan birga himoyalangan barcha kabelga mos kelishini tekshiring.
  • Yadro tutash sirtini toza saqlang va siqish tasmasini tortishdan oldin to’liq aloqani ta’minlang.
  • Agar bo’linadigan yadro tanasi to’liq yopilmagan yoki siqish tasmasi bo’sh bo’lsa, tizimni kuchlanish ostiga qo’ymang.
  • Transformatorni tasdiqlangan chizmaga muvofiq ichki shkaf yoki kabel kamerasiga o’rnating.
  • O’rnatish, sinov va texnik xizmat ko’rsatish malakali elektr mutaxassislari tomonidan amalga oshirilishi kerak.

Tanlash yo’riqnomalari

  1. Ichki diametrni tasdiqlang: Himoyalangan to’liq kabel guruhining tashqi o’lchamlariga qarab φ80, φ100, φ120, φ150, φ180, φ200, φ240 yoki φ260 ni tanlang.
  2. Bo’linadigan yadro talabini tasdiqlang: Kabel allaqachon o’rnatilgan yoki uzib bo’lmasa, ochiladigan LXK dan foydalaning.
  3. Tana qalinligini tasdiqlang: Nominal chiqish talabi va shkaf chuqurligiga qarab 55, 57, 65, 80 yoki 100 mm tuzilmani tanlang.
  4. Tok nisbatini tasdiqlang: Rele kirishiga, sozlash diapazoniga va xato aniqlash talabiga qarab nisbatni tanlang.
  5. Ikkilamchi tokni tanlang: Rele yoki kuzatish qurilmasi kirishiga qarab 5 A yoki 1 A ni tanlang.
  6. Himoya klassini tanlang: Talab qilingan himoya aniqligi va yuklamaga qarab 10P5 dan 10P20 gacha tanlang.
  7. Sim tortish yuklamasini tekshiring: Rele kirishi, ikkilamchi kabel va terminal yuklamasi nominal chiqishdan oshmasligi kerak.
  8. O’tkazgich yo’naltirishini tekshiring: Himoya sxemasiga qarab kabel ekran, zirh, neytral yoki PE o’tkazgichi tok transformatoridan o’tishi yoki uning atrofidan o’tishi kerakligini tasdiqlang.

Tez-tez so’raladigan savollar

U ichki elektr taqsimlash tizimlari va kichik tokli yerlov tizimlarida kabel yer xatosi himoyasi, nol ketma-ketligidagi tokni aniqlash va qoldiq tokni kuzatish uchun ishlatiladi.

Odatiy ichki diametrlarga φ80, φ100, φ120, φ150, φ180, φ200, φ240 va φ260 kiradi. To’g’ri teshik himoyalangan kabel guruhining to’liq tashqi o’lchamlariga qarab tanlanishi kerak.

Bo’linadigan yadroli tuzilma kabel boshlig’ini uzish yoki olib tashlamasdan mavjud kabel atrofida ochilib o’rnatilishi mumkin, bu yangilash ishlari va o’rnatilgan kommutatsion jihozlar uchun mos keladi.

Himoyalangan barcha fazaviy o’tkazgichlar bir xil yo’nalishda bir xil teshikdan o’tishi kerak. Bu transformator qoldiq tok vektor yig’indisini to’g’ri o’lchashini ta’minlaydi.

Yo’q. Nol ketma-ketligi himoyasi uchun faqat bitta fazaviy o’tkazgich teshikdan o’tmasligi kerak. To’liq himoyalangan o’tkazgich guruhlari birgalikda o’tishi kerak.

Nominal ikkilamchi tok ulangan rele, himoya qurilmasi yoki kuzatish tizimiga qarab 5 A yoki 1 A sifatida tanlanishi mumkin.

LXK seriyasi model hajmi, tok nisbati va nominal chiqish talabiga qarab 10P5 dan 10P20 gacha himoya klasslarini qo’llab-quvvatlaydi.

LXK-φ120 himoyalangan to’liq kabel guruhini o’rnatish bo’shlig’i bilan 120 mm teshikdan o’tkazish mumkin bo’lganda tanlanadi. Aniq tananing hajmi, masalan, 120/204×57 yoki 120/250×80, chiqish va shkaf maydoni talablariga bog’liq.

Birlamchi zanjir kuchlanish ostida bo’lganda tok transformatori ikkilamchi zanjiri ochiq zanjir bo’lmasligi kerak. Ochiq ikkilamchi zanjir yuqori kuchlanish hosil qilishi, izolyatsiyani shikastlashi va xavfsizlik xavfini yaratishi mumkin.

Iltimos, ichki diametr, o’lcham kodi, tok nisbati, ikkilamchi tok, himoya klassi, nominal chiqish, kabel guruh hajmi, rele modeli, o’rnatish tartibi, miqdori hamda chizmalar, yorliqlar, sertifikatlar yoki qadoqlash talablari haqida ma’lumot bering.