Mahsulotga umumiy ko’rib chiqish
LXZ1(2)-80/100/120/140/160/180 ichki qurilishli epoksid smola izolyatsiyali nol ketma-ketligidagi tok transformatori kabel yerga ulanish xatolarini aniqlash, qoldiq tokni kuzatish va AC elektr tarmoqlarida yerlov himoyasi uchun mo’ljallangan. U 50 Hz yoki 60 Hz nominal chastotaga va 0,72/3 kV nominal izolyatsiya darajasiga ega ichki qurilishli ilovalar uchun mos keladi. Mahsulot himoya relelari, kuzatish qurilmalari va yerga ulanish xatosini aniqlash tizimlari uchun 5 A yoki 1 A ikkilamchi tok chiqishini ta’minlaydi.
Ushbu seriya — epoksid smola izolyatsiyali halqasimon yadroli, teshikli, bir fazali nol ketma-ketligidagi tok transformatoridir. O’rnatish paytida uch fazali kabel guruhlari transformatorning markaziy teshigidan o’tkaziladi. Oddiy ishlash sharoitida uch fazali toklarning vektor yig’indisi nolga yaqin bo’ladi. Bitta fazaning yerga ulanish xatosi yoki izolyatsiya xatosi sodir bo’lganda nol ketma-ketligidagi tok hosil bo’ladi va transformator proporsional ikkilamchi signalni rele himoyasi yoki ogohlantirish ishlashi uchun beradi.
Mahsulot turi
| Element | Xususiyatlar |
|---|---|
| Mahsulot nomi | Ichki qurilishli epoksid smola izolyatsiyali nol ketma-ketligidagi tok transformatori |
| Model seriyasi | LXZ1(2)-80 / 100 / 120 / 140 / 160 / 180 |
| Mahsulot tuzilishi | Ichki qurilishli epoksid smola izolyatsiyali halqasimon yadroli nol ketma-ketligidagi tok transformatori |
| Teshik diametri variantlari | 80 mm, 100 mm, 120 mm, 140 mm, 160 mm, 180 mm |
| Nominal izolyatsiya darajasi | 0.72/3kV |
| Nominal chastota | 50Hz / 60Hz |
| Nominal ikkilamchi tok | 5A yoki 1A |
| Himoya klassi | Tanlangan model va nisbatga qarab 10P5, 10P10, 10P15, 10P20 |
| O’rnatish joyi | Ichki qurilish |
| Odatiy ilovalar | Nol ketma-ketligidagi tokni aniqlash, kabel yerga ulanish xatosidan himoya, qoldiq tokni kuzatish, yerlov himoyasi |
Mahsulot namoyishi


Asosiy ilovalar
- Ichki qurilishli kabel liniyasi yerga ulanish xatosidan himoya
- Past kuchlanishli va taqsimlash tizimlarida nol ketma-ketligidagi tokni aniqlash
- Uch fazali kabel guruhlari uchun qoldiq tokni kuzatish
- Kichik tokli yerlov tizimi himoyasi
- Bitta fazaning yerga ulanish xatosi haqida ogohlantirish va uzish zanjirlari
- Elektrodvigatel liniyasi, generator liniyasi va taqsimlash liniyasi himoyasi
- Kommutatsion jihozlar, himoya shkafchalari va quvvat kuzatish tizimlari
Asosiy texnik xususiyatlar
- Nol ketma-ketligidagi himoya dizayni: Bitta fazaning yerga ulanish xatosi yoki izolyatsiya xatosi natijasida hosil bo’ladigan qoldiq tokni aniqlash uchun mo’ljallangan.
- Epoksid smola izolyatsiyasi: Halqasimon yadro va ikkilamchi o’ram epoksid smola bilan qoplangan bo’lib, bu izolyatsiya xususiyatlarini, namlikka chidamliligini va mexanik barqarorlikni ta’minlaydi.
- Turli xil teshik variantlari: Har xil kabel diametrlari va o’rnatish sxemalari uchun 80 mm dan 180 mm gacha teshik o’lchamlari mavjud.
- 5A yoki 1A ikkilamchi chiqish: Oddiy himoya relelari, kuzatish qurilmalari va tok kirish asboblari bilan mos keladi.
- Himoya klassi variantlari: Tok nisbati va yuklama talablari asosida 10P5, 10P10, 10P15 va 10P20 mavjud.
- Ichki qurilishda doimiy o’rnatish: Teshikli korpus va o’rnatish poydevori shkaf o’rnatish va kabel liniyasi himoyasi ilovalarini qo’llab-quvvatlaydi.
Ish prinsipi
LXZ1(2) nol ketma-ketligidagi tok transformatori uch fazali kabel guruhidan o’tayotgan toklarning vektor yig’indisini o’lchaydi. Tizim oddiy ishlaganda uch fazali toklar muvozanatlangan bo’ladi va vektor yig’indisi taxminan nolga teng bo’ladi, shuning uchun ikkilamchi chiqish juda kichik bo’ladi. Bitta fazaning yerga ulanish xatosi sodir bo’lganda uch fazali tok muvozanati buziladi va nol ketma-ketligidagi tok paydo bo’ladi. Transformator ushbu qoldiq tokni ikkilamchi signalga aylantirib, uni rele himoyasi, ogohlantirish yoki kuzatish uchun ishlatadi.
To’g’ri ishlashi uchun barcha uch fazali o’tkazgichlar transformator teshigidan bir xil yo’nalishda o’tishi kerak. Kabel yoki o’tkazgich birlamchi izolyatsiyani ta’minlaydi, transformator tanasi esa magnit yadro va ikkilamchi o’ram uchun izolyatsiya va mexanik himoyani ta’minlaydi.
Model belgilash

Model kodi quyidagicha izohlanadi:
| Kod | Ma’nosi |
|---|---|
| L | Tok transformatori |
| X | Nol ketma-ketligidagi tok transformatori turi |
| Z | Epoksid smola izolyatsiyali tuzilish |
| 1 / 2 | Dizayn tuzilish kodi |
| 80 / 100 / 120 / 140 / 160 / 180 | Teshik diametri yoki tuzilish o’lchami kodi |
Texnik ma’lumotlar
| Element | Xususiyatlar |
|---|---|
| Model seriyasi | LXZ1(2)-80/100/120/140/160/180 |
| Mahsulot turi | Ichki qurilishli epoksid smola izolyatsiyali nol ketma-ketligidagi tok transformatori |
| Nominal izolyatsiya darajasi | 0.72/3kV |
| Nominal chastota | 50Hz / 60Hz |
| Nominal ikkilamchi tok | 5A yoki 1A |
| Himoya klassi | 10P5, 10P10, 10P15, 10P20 |
| Atrof-muhit harorati | -25°C dan +40°C gacha |
| Izolyatsiya tuzilishi | Epoksid smola izolyatsiyasi |
| Qo’llaniladigan standartlar | GB 20840.1-2010, GB 20840.2-2014; mijozning maxsus talablari kelishuv orqali tasdiqlanishi mumkin |
Model teshigi va o’lchamlar jadvali
| Model | d (mm) | D (mm) | H (mm) | h (mm) | a (mm) | b (mm) | c (mm) |
|---|---|---|---|---|---|---|---|
| LXZ1-80 | 80 | 195 | 130 | 50 | 80 | – | 120 |
| LXZ2-80 | 80 | 195 | 130 | 80 | 80 | 50 | 120 |
| LXZ1-100 | 100 | 215 | 140 | 50 | 80 | – | 120 |
| LXZ2-100 | 100 | 215 | 140 | 80 | 80 | 50 | 120 |
| LXZ1-120 | 120 | 235 | 150 | 50 | 100 | – | 140 |
| LXZ2-120 | 120 | 235 | 150 | 80 | 100 | 50 | 140 |
| LXZ1-140 | 140 | 255 | 160 | 50 | 100 | – | 140 |
| LXZ2-140 | 140 | 255 | 160 | 80 | 100 | 50 | 140 |
| LXZ1-160 | 160 | 265 | 170 | 60 | 100 | – | 140 |
| LXZ2-160 | 160 | 265 | 170 | 80 | 100 | 30 | 140 |
| LXZ1-180 | 180 | 295 | 180 | 50 | 160 | – | 200 |
| LXZ2-180 | 180 | 295 | 180 | 80 | 160 | 50 | 200 |
Birlik: mm. Yakuniy o’lchamlar, o’rnatish teshiklari, terminal joylari va korpus qalinligi tasdiqlangan kontur chizmaga bog’liq.
Nominal tok nisbati va chiqish jadvali
| Model guruhi | Himoya klassi | 5A ikkilamchi tok nisbati | 5A ikkilamchi tok uchun nominal chiqish diapazoni (VA) | 1A ikkilamchi tok nisbati | 1A ikkilamchi tok uchun nominal chiqish diapazoni (VA) |
|---|---|---|---|---|---|
| LXZ1-80/100/120/140/160/180 | 10P5 | 50/5, 75/5, 100/5, 150/5, 200/5, 250/5, 300/5, 400/5 | Model va nisbatga qarab 5 dan 40 gacha | 50/1, 75/1, 100/1, 150/1 | Model va nisbatga qarab 5 dan 15 gacha |
| LXZ1-80/100/120/140/160/180 | 10P10 | 50/5 dan 400/5 gacha | Model va nisbatga qarab 2,5 dan 20 gacha | 50/1 dan 150/1 gacha | Model va nisbatga qarab 2,5 dan 7,5 gacha |
| LXZ1-80/100/120/140/160/180 | 10P15 | 50/5 dan 400/5 gacha | Model va nisbatga qarab 1 dan 15 gacha | 50/1 dan 150/1 gacha | Model va nisbatga qarab 2 dan 5 gacha |
| LXZ1-80/100/120/140/160/180 | 10P20 | 50/5 dan 400/5 gacha | Model va nisbatga qarab 1 dan 10 gacha | 50/1 dan 150/1 gacha | Model va nisbatga qarab 1 dan 3,75 gacha |
| LXZ2-80/100/120/140/160/180 | 10P5 / 10P10 / 10P15 / 10P20 | 50/5 dan 400/5 gacha | Model, nisbat va klassga qarab 1 dan 80 gacha | 50/1 dan 150/1 gacha | Model, nisbat va klassga qarab 2 dan 30 gacha |
Eslatma: Nominal chiqish teshik o’lchamiga, ikkilamchi tokka, himoya klassiga va tanlangan tok nisbatiga qarab farq qiladi. Katalog jadvalidan tashqari qiymatlar texnik kelishuv orqali tasdiqlanishi mumkin.
Xizmat ko’rsatish shartlari
- O’rnatish joyi: ichki qurilish
- Nominal izolyatsiya darajasi: 0.72/3kV
- Nominal chastota: 50Hz / 60Hz
- Atrof-muhit harorati: -25°C dan +40°C gacha
- O’rnatish muhiti kuchli titrovlanish, korroziyaga sababchi gaz, o’tkazuvchan chang, portlovchi muhit va kuchli ifloslanishdan xoli bo’lishi kerak.
- Barcha uch fazali o’tkazgichlar transformator teshigidan birgalikda bir xil yo’nalishda o’tishi kerak.
- Kabel, shina yoki o’tkazgich yetarli izolyatsiya tiniq bo’shlig’iga ega bo’lishi va transformator tanasiga mexanik kuchlanish qo’llamasligi kerak.
- Maxsus kabel diametri, yerlov himoya sxemasi, yuklama yoki himoya klassi talablari bo’lsa, buyurtma berishdan oldin texnik tasdiqlash tavsiya etiladi.
Standartlar va moslik
LXZ1(2) nol ketma-ketligidagi tok transformatori seriyasi GB 20840.1-2010 va GB 20840.2-2014 standartlariga muvofiq ishlab chiqariladi va mijozning loyiha talablari asosida ham yetkazib berilishi mumkin. Yakuniy tok nisbati, nominal chiqish, himoya klassi, rutin test elementlari va yorliq ma’lumotlari texnik kelishuvda tasdiqlanishi kerak.
O’rnatish va o’lchamlar

LXZ1(2) seriyasi teshikli halqasimon yadroli tuzilishga ega. Uch fazali kabel guruhlari, shina guruhlari yoki o’tkazgich guruhlari markaziy teshikdan o’tkaziladi va ikkilamchi terminal S1 va S2 deb belgilanadi. Model talab qilingan teshik diametri, o’rnatish qalinligi, o’rnatish joyi va shkaf sxemasiga qarab tanlanishi kerak.
Ulanish va sim tortish eslatmalari
- Barcha uch fazali o’tkazgichlar transformator teshigidan birgalikda bir xil yo’nalishda o’tishi kerak.
- Transformator nol ketma-ketligidagi himoya uchun ishlatilganda faqat bitta fazali o’tkazgichni teshikdan o’tkazmang.
- Ikkilamchi terminal S1 va S2 ni ulash sxemasiga muvofiq himoya relesi yoki kuzatish qurilmasiga ulang.
- Ishga tushirishdan oldin polarlikni, terminalni mahkamlashni, rele sozlamalarini va ikkilamchi simlarning uzluksizligini tekshiring.
- Birlamchi zanjir toklanayotganda tok transformatorining ikkilamchi zanjiri ochiq zanjir bo’lishi mumkin emas.
- Ikkilamchi sim tortish, yerlov va terminal himoyasi loyiha talablari va mahalliy elektr qoidalariga mos kelishi kerak.
O’rnatish va xavfsizlik eslatmalari
- O’rnatishdan oldin modelni, teshik o’lchamini, tok nisbatini, ikkilamchi tokni, himoya klassini va nominal chiqishni tasdiqlang.
- Kabel yoki o’tkazgich guruhining transformator tanasini majbur qilmasdan teshikdan o’tishini ta’minlang.
- Transformatorni tasdiqlangan chizmaga muvofiq ichki qurilishli shkaf yoki panelga o’rnating.
- Kabel guruhini teshikda barqaror qoldiq tokni aniqlashni qo’llab-quvvatlash uchun iloji boricha markazlashtiring.
- Quvvat berishdan oldin terminal belgilarini, o’rnatish teshiklarini, ikkilamchi simlarni va rele ulanishini tekshiring.
- O’rnatish va texnik xizmat ko’rsatish malakali elektr mutaxassislari tomonidan amalga oshirilishi kerak.
Buyurtma ma’lumotlari
Buyurtma berish yoki narx-so’rov yuborishda quyidagi ma’lumotlarni taqdim eting:
- Mahsulot modeli: LXZ1 yoki LXZ2 va teshik o’lchami 80 / 100 / 120 / 140 / 160 / 180
- Nominal tok nisbati, masalan, 100/5, 200/5, 300/5, 400/5, 50/1 yoki 100/1
- Nominal ikkilamchi tok: 5A yoki 1A
- Talab qilinayotgan himoya klassi: 10P5, 10P10, 10P15 yoki 10P20
- Nominal chiqish / yuklama VA da
- Nominal chastota va o’rnatish muhiti
- Kabel guruhining, shina guruhining yoki o’tkazgich guruhining maksimal tashqi o’lchami
- Rele modeli, himoya sxemasi va yerga ulanish xatosini aniqlash talablari
- Miqdori, chizma talablari, sertifikatlar, tekshiruv hujjatlari, yorliqlar yoki qadoqlash talablari
Tanlash yo’riqnomalari
- Teshik o’lchamini tasdiqlang: Uch fazali kabel yoki o’tkazgich guruhining tashqi o’lchamiga qarab 80, 100, 120, 140, 160 yoki 180 ni tanlang.
- LXZ1 yoki LXZ2 tuzilishini tanlang: O’rnatish qalinligi, terminal joylashuvi va o’rnatish sxemasiga qarab tuzilish turini tanlang.
- Nol ketma-ketligidagi ilovani tasdiqlang: Himoya tizimi qoldiq tok yoki yerga ulanish tokini aniqlashni talab qilganda ushbu seriyadan foydalaning.
- Tok nisbatini tasdiqlang: Rele kirish va himoya sozlamalari talabiga qarab nisbatni tanlang.
- Ikkilamchi tokni tanlang: Ulangan rele yoki kuzatish qurilmasiga qarab 5A yoki 1A ni tanlang.
- Himoya klassini tanlang: Himoya zanjiri talabiga qarab 10P5, 10P10, 10P15 yoki 10P20 ni tanlang.
- Nominal yuklamani tekshiring: Relelar, o’lchagichlar, simlar va terminal bloklarining umumiy yuklamasi nominal chiqishdan oshmasligi kerak.
- O’lchamlarni tasdiqlang: Seriyali o’rnatishdan oldin kontur chizmani, o’rnatish teshiklarini va shkaf bo’shlig’ini tekshiring.