LDC(D)-10, LMC(D)-10 Ichki devor orqali o’tadigan turdagi tokli transformator

LDC(D)-10, LMC(D)-10 Ichki devor orqali o’tadigan turdagi tokli transformator

10 kV, 11 kV va 12 kV hisoblash, namuna olish va himoya uchun ichki devor orqali o'tkaziladigan hamda magistral turdagi tok transformatorlari

  • LDC-10, LDCD-10, LDCQ-10, LDCQD-10, LMC-10 va LMCD-10 modellarini qamrab oladi
  • Tokni o'lchash, elektr energiyasini hisoblash, signal namunalarini olish, releli himoya va mikrokomp'yuter asosidagi himoya maqsadlarida ishlatish uchun mo'ljallangan
  • 10 kV, 11 kV va 12 kV ichki qurilmalar uchun IEC standartiga mos 12/42/75 kV izolyatsiya koordinatsiyasi
  • LMC / LMCD magistral turdagi konstruktsiyalari 2000/5 dan 5000/5 gacha bo'lgan yuqori tok nisbatlarini qo'llab-quvvatlaydi
  • Ikkinchi tomon chiqishi sifatida standart 5 A taqdim etiladi; loyiha talablari asosida 1 A ham mavjud

Mahsulotga umumiy ko’rib chiqish

LDC(D)-10 / LMC(D)-10 tok transformatori — o’rta kuchlanishli AC elektr tarmoqlari uchun mo’ljallangan ichki devor orqali o’tkaziladigan turdagi tok transformatoridir. U 10 kV, 11 kV va 12 kV sinfli elektr taqsimlash uskunalarida tokni o’lchash, elektr energiyasini hisoblash, signal namunasi olish, releli himoya va mikrokomp’yuter asosidagi himoya maqsadlarida ishlatiladi.

Ushbu mahsulot oilasiga birlamchi o’tkazgich transformator tanasidan o’tadigan yoki unga ulanadigan kommutatsion apparatlar va taqsimlash uskunalari uchun mo’ljallangan devor orqali o’tkaziladigan hamda magistral turdagi konstruktsiyalar kiradi. LMC(D)-10 versiyasi devor orqali o’tkazish / magistral turdagi o’rnatishlar uchun ishlatiladi, LDC(D)-10 seriyasi esa o’rta kuchlanishli tizimlarda ichki tokni o’lchash va himoya dasturlarida qo’llaniladi. D versiyasi differensial himoya yoki himoyaga yo’naltirilgan ikkilamchi sozlamalar talab qilinganda ishlatiladi.

Xalqaro loyihalar uchun mahsulot IEC standartlariga mos keladigan 12 kV sinfli izolyatsiya muvofiqlik darajasiga ega bo’lishi mumkin. Odatiy izolyatsiya darajasi 10 kV, 11 kV va 12 kV tizimlari uchun 12/42/75 kV hisoblanadi. Konstruksiya ixcham, yengil va kommutatsion apparatlarga o’rnatish qulay bo’lib, hisob-kitob va himoya qurilmalari uchun ishonchli ikkilamchi tok chiqishini ta’minlaydi.

Mahsulot turi

Element Tavsif
Mahsulot nomi Ichki devor orqali o’tkaziladigan turdagi tok transformatori
Model seriyasi LDC-10 / LDCD-10 / LDCQ-10 / LDCQD-10 / LMC-10 / LMCD-10
Mahsulot konstruksiyasi OKV kommutatsion apparatlari uchun ichki devor orqali o’tkaziladigan / magistral turdagi tok transformatori
Kuchlanish sinfi 10 kV, 11 kV va 12 kV o’rta kuchlanishli tizimlar
Uskuna uchun eng yuqori kuchlanish 12 kV sinfi
Nominal izolyatsiya darajasi IEC 12 kV sinfli izolyatsiya muvofiqlik darajasi uchun 12/42/75 kV ma’lumotnomasi
Nominal chastota 50 Hz / 60 Hz
Nominal ikkilamchi tok Standart 5 A; loyiha talabiga ko’ra 1 A mavjud
Qo’llash turi Tokni o’lchash, energiya hisobini yuritish, signal namunasi olish, releli himoya, mikrokomp’yuter himoyasi
O’rnatish joyi Ichki kommutatsion apparatlar, taqsimlash shkafi, devor orqali panel va OKV elektr uskunalari
Qo’llaniladigan standart IEC 61869-1 / IEC 61869-2; eski loyihalar uchun IEC 60044-1 qo’llanilishi mumkin

Mahsulot namoyishi

Mahsulot namoyishi

LDCD 10

Qo’llash sohalari

  • 10 kV, 11 kV va 12 kV ichki o’rta kuchlanishli kommutatsion apparatlar
  • Tokni o’lchash va energiya hisobini yuritish uchun elektr ta’minoti va taqsimlash uskunalari
  • Aqlli nazorat qurilmalari uchun signal namunasi olish zanjirlari
  • Releli himoya va mikrokomp’yuter himoya tizimlari
  • CT ham bo’limlar orasidagi izolyatsiya ajratuvchi sifatida xizmat qiladigan devor orqali o’rnatish
  • 2000 A, 3000 A, 4000 A va 5000 A kabi yuqori tokli magistral turdagi dasturlar

Xususiyatlari

  • Devor orqali konstruksiya: Birlamchi o’tkazgichlar kommutatsion apparatlar bo’linmalari yoki izolyatsiyalangan to’siqlardan o’tadigan o’rta kuchlanishli shkafchalar uchun mos keladi.
  • Ko’plab model variantlari: LDC, LDCD, LDCQ, LDCQD, LMC va LMCD variantlari turli o’lchash, himoya, magistral turdagi va differensial himoya konfiguratsiyalarini qo’llab-quvvatlaydi.
  • IEC kuchlanish ifodasi: 12/42/75 kV izolyatsiya muvofiqlik darajasi bilan 10 kV, 11 kV va 12 kV tizimlari uchun belgilanishi mumkin.
  • O’lchash va himoya chiqishlari: 0,5, 1 va 3 kabi hisob-kitob klasslarini hamda 10P himoya konfiguratsiyalarini qo’llab-quvvatlaydi.
  • Yuqori tok quvvati: LMC / LMCD konstruksiyalari 2000/5, 3000/5, 4000/5 va 5000/5 kabi yuqori birlamchi tok nisbatlarini qo’llab-quvvatlaydi.
  • Ixcham o’rnatish: Kichik hajm, past og’irlik va qulay o’rnatish bilan kommutatsion apparatlarga integratsiya qilish uchun mo’ljallangan.

Ish prinsipi

LDC(D)-10 / LMC(D)-10 tok transformatori elektromagnit induksiya prinsipiga asoslanib ishlaydi. O’tkazgich yoki magistraldagi birlamchi tok CT yadrosida magnit oqimini hosil qiladi va ikkilamchi o’ram proporsional tok signali hisob-kitob qurilmalari, himoya releylari yoki nazorat qurilmalariga chiqariladi. Izolyatsiya konstruksiyasi o’rta kuchlanishli birlamchi zanjirni past kuchlanishli ikkilamchi zanjirdan ajratadi va nominal xizmat sharoitlarida xavfsiz signal uzatishni ta’minlaydi.

Hisob-kitob zanjirlari uchun CT nominal ikkilamchi yuk ostida belgilangan nisbat aniqlik va fazaviy siljishni saqlashi kerak. Himoya va mikrokomp’yuter himoya zanjirlari uchun himoya o’rami ishonchli nosozlik tok signali berishi va rele sozlamasi, nominal yuk, aniqlik chegarasi koeffitsienti hamda qisqa tutashuvga chidamlilik darajasi bilan muvofiqlashtirilishi kerak.

Model belgilash

Model belgilash

Model belgilash tok transformatorining turini, devor orqali yoki magistral turdagi konstruksiyasini, differensial himoya variantini va kuchlanish sinfini aniqlaydi.

Kod Ma’nosi
L Tok transformatori
D Devor orqali o’tkazish / maxsus ichki kommutatsion apparatlar konstruksiyasi
M Magistral turdagi konstruksiya
C Model seriyasiga ko’ra devor orqali izolyatsiya konstruksiyasi
Qavsdagi D Differensial himoya versiyasi yoki himoyaga yo’naltirilgan konfiguratsiya
Q Loyiha konfiguratsiyasiga ko’ra kuchaytirilgan yoki maxsus konstruksiya versiyasi
10 Kuchlanish sinfi identifikatori; 10 kV tizimlari va 10 kV, 11 kV va 12 kV loyihalar uchun IEC 12 kV sinfli izolyatsiya muvofiqlik darajasi uchun ishlatiladi

Model qamrovi: Ushbu mahsulot sahifasi LDC-10, LDCD-10, LDCQ-10, LDCQD-10, LMC-10 va LMCD-10 ni qamrab oladi. Yakuniy model tanlovi tok nisbati, kommutatsion apparatlar o’rnatish turi, izolyatsiya talablari, hisob-kitob/himoya konfiguratsiyasi va tasdiqlangan chizma asosida amalga oshirilishi kerak.

Texnik ma’lumotlar

Element Tavsif
Nominal kuchlanish sinfi 10 kV / 11 kV / 12 kV o’rta kuchlanishli tizimlar
Uskuna uchun eng yuqori kuchlanish 12 kV sinfi
Nominal izolyatsiya darajasi 12/42/75 kV ma’lumotnomasi
Nominal chastota 50 Hz / 60 Hz
Nominal birlamchi tok Modelga qarab 400 A dan 5000 A gacha; maxsus nisbatlar mavjud
Nominal ikkilamchi tok Standart 5 A; loyiha talabiga ko’ra 1 A mavjud
Aniqlik klassi kombinatsiyasi 0,5 / 0,5, 1 / 1, 0,5 / 3, 10P / 0,5, 10P / 1, 10P / 3, 10P / 10P
Nominal chiqish Hisob-kitob klasslari uchun 20 VA / 30 VA / 50 VA; himoya klassi uchun 15 VA ma’lumotnomasi
Himoya klassi Model va himoya talabiga qarab 10P15 yoki 10P20
O’rnatish usuli Kommutatsion apparatlar tartibiga qarab ichki devor orqali yoki magistral turdagi o’rnatish
Qo’llaniladigan standart IEC 61869-1 / IEC 61869-2; eski texnik shartnomalar uchun IEC 60044-1 qo’llanilishi mumkin

Terminal belgilari

LDC(D)-10 / LMC(D)-10 tok transformatori o’lchash, hisob-kitob, himoya yoki differensial himoya uchun ikkilamchi o’ram konfiguratsiyalari bilan yetkazib berilishi mumkin. Terminal tartibi tanlangan model va kommutatsion apparatlar chizmasiga qarab tasdiqlanishi kerak.

Terminal belgilari Funksiyasi Qo’llash eslatmasi
P1 / P2 Birlamchi terminallar Referens birlamchi tok yo’nalishi odatda P1 dan P2 ga qarab belgilanadi.
1S1 / 1S2 Birinchi ikkilamchi o’ram Odatda hisob-kitob, o’lchash yoki signal namunasi olish uchun ishlatiladi.
2S1 / 2S2 Ikkinchi ikkilamchi o’ram Odatda releli himoya, mikrokomp’yuter himoyasi yoki differensial himoya uchun ishlatiladi.
Yerga ulash terminali Ikkilamchi yerga ulash nuqtasi Yerga ulash loyiha sim chizmasi va elektr xavfsizligi talablari asosida amalga oshirilishi kerak.

Terminal belgilari standart CT polyuslik an’analarga rioya qiladi. Hisob-kitob aniqligi, releli himoya samaradorligi va xavfsiz texnik xizmat ko’rsatishni ta’minlash uchun to’g’ri terminal identifikatsiyasiga e’tibor berish kerak. Birlamchi zanjir kuchlanish ostida bo’lganda ikkilamchi zanjirni ochiq zanjir qilib qo’ymaslik kerak.

Tanlov jadvali

Turi Nominal

Tok

Nisbati

Aniqlik

Klassi

Kombinatsiyasi

O’lchash

Chiqish (VA)

Himoya

Chiqish (VA)

Himoya

Klassi

Qisqa muddatli

Issiqlik

Toki

Nominal

Dinamik

Tok

LDC-10 600/5 0.5 / 0.5
1 / 1
0.5 / 3
20 / 20 / 50 48kA 78kA
750/5 60kA 90kA
1000/5 80kA 90kA
1500/5 120kA 99kA
LDCD-10 600/5 10P / 0.5
10P / 1
10P / 10P
20 / 20 15 10P20 48kA 78kA
750/5 60kA 79kA
1000/5 80kA 90kA
1500/5 120kA 99kA
LDCQ-10 400/5 1 / 1
1 / 3
20 / 50 48kA 80kA
600/5 72kA 90kA
750/5 90kA 90kA
LDCQD-10 600/5 10P / 0.5
10P / 1
10P / 3
10P / 10P
20 / 20 / 50 15 10P20 72kA 78kA
750/5 90kA 79kA
1000/5 120kA 90kA
LMC-10 2000/5 0.5 / 0.5
0.5 / 3
30 / 50 Himoya konfiguratsiyasi uchun 10P15 ma’lumotnomasi Loyihaga bog’liq Loyihaga bog’liq
3000/5
4000/5
5000/5
LMCD-10 2000/5 10P / 0.5
10P / 3
10P / 10P
30 / 50 15
3000/5
4000/5
5000/5

Eslatma: Tanlov jadvali dastlabki muhandislik ma’lumotnomasi uchundir. Yakuniy tok nisbati, ikkilamchi tok, aniqlik klassi kombinatsiyasi, nominal chiqish, himoya klassi, qisqa muddatli issiqlik toki, dinamik tok, izolyatsiya darajasi va terminal tartibi tasdiqlangan chizma, nom plakati va zavod sinov hisoboti asosida tasdiqlanishi kerak.

LMC ma’lumotlari

Element LMC(D)-10 Ma’lumotnomasi
Nominal birlamchi tok Texnik shartnomaga qarab 200 A / 3000 A / 4000 A / 5000 A ma’lumotnomasi variantlari
Nominal ikkilamchi tok 5 A
Nominal chastota 50 Hz
0,5 klassi uchun nominal chiqish 10 VA
B klassi / himoya ma’lumotnomasi uchun nominal chiqish 15 VA
Izolyatsiya darajasi Eski ma’lumotlarda 10/42/75 kV ma’lumotnomasi; 12 kV sinfli loyihalar uchun IEC 12/42/75 kV belgilanishi mumkin
Qisqa muddatli issiqlik toki 75 × I1n ma’lumotnomasi
Nominal dinamik tok 2,5 × Ith ma’lumotnomasi
10% ko’paytma 10

Xizmat ko’rsatish sharoitlari

  • O’rnatish joyi: ichki o’rta kuchlanishli kommutatsion apparatlar yoki devor orqali panel
  • Tizim kuchlanishi: 10 kV, 11 kV yoki 12 kV sinfi
  • Nominal chastota: 50 Hz / 60 Hz
  • Nominal izolyatsiya darajasi: IEC uslubidagi 12 kV sinfli loyihalar uchun 12/42/75 kV ma’lumotnomasi
  • Atrof-muhit harorati: -5°C dan +40°C gacha ma’lumotnomasi oralig’i
  • Namlik, ifloslanish va kondensatsiya sharoitlari nazorat qilinadigan ichki kommutatsion apparatlar uchun mos keladi
  • O’rnatish joyi kuchli titrov, korroziyaga sababchi gaz, portlovchi muhit, og’ir o’tkazuvchi chang va noaniq kondensatsiyadan xoli bo’lishi kerak.
  • Yuqori tokli magistral dasturlari uchun issiqlik tarqatish, zazoralash va mexanik mustahkamlash kommutatsion apparatlar dizayni bilan birgalikda tasdiqlanishi kerak.

Standartlar va moslik

LDC(D)-10 / LMC(D)-10 tok transformatori IEC 61869-1 va IEC 61869-2 asosida yetkazib berilishi mumkin. Eski loyiha texnik shartnomalari uchun IEC 60044-1 qo’llanilishi mumkin. Muntazam sinovlar, dielektrik sinovlar, polyuslik tekshiruvi, nisbat sinovi, aniqlik sinovi, izolyatsiya qarshiligi va qisman razryad talablari yakuniy texnik kelishuv asosida tasdiqlanishi kerak.

O’rnatish va o’lchamlar

O'rnatish va o'lchamlar

LDC(D)-10 / LMC(D)-10 seriyasi ichki devor orqali yoki magistral turdagi kommutatsion apparatlar o’rnatish uchun mo’ljallangan. Birlamchi o’tkazgich tartibi, izolyatsiya tanasi, ikkilamchi terminal qutisi, mahkamlash teshiklari, yuzma masofa va shkaf interfeysi kommutatsion apparatlar dizayni yoki seriyali ishlab chiqarishdan oldin tasdiqlangan tashqi chizma asosida tasdiqlanishi kerak.

Tashqi ma’lumotlar

Element Tanlov eslatmasi
Mexanik konstruksiya Ichki devor orqali o’tkaziladigan / magistral turdagi tok transformatori
Birlamchi ulanish Modelga qarab devor orqali o’tkazgich, magistral yoki kommutatsion apparatlar ulanishi
Ikkilamchi terminallar Tanlangan o’ram konfiguratsiyasiga qarab terminal blok tartibi
Mahkamlash usuli Tasdiqlangan chizmaga qarab kommutatsion apparatlar devoriga o’rnatish
Chizmani tasdiqlash Yakuniy tashqi ko’rinish, yuzma masofa, terminal yo’nalishi va mahkamlash o’lchamlari ishlab chiqarishdan oldin tasdiqlanishi kerak

Xavfsizlik eslatmalari

  • O’rnatishdan oldin model, kuchlanish sinfi, tok nisbati, ikkilamchi tok, aniqlik klassi, nominal chiqish, izolyatsiya darajasi va sim ulash tartibini tasdiqlang.
  • Birlamchi o’tkazgich tartibi, devor orqali teshik, magistral zazoralashi, fazadan yerga zazoralash va kommutatsion apparatlar tartibini tasdiqlangan chizma asosida tekshiring.
  • Ikkilamchi terminallarni terminal belgilari va loyiha sim chizmasi asosida ulang.
  • Birlamchi zanjir kuchlanish ostida bo’lganda tok transformatorining ikkilamchi zanjiri ochiq qolmasligi kerak.
  • Hisob-kitob qurilmasi yoki rele texnik xizmat ko’rsatish paytida ikkilamchi simlarni uzishdan oldin CT ikkilamchi zanjirini qisqa tutash kerak.
  • Ikkilamchi yerga ulash loyiha texnik shartnomasi va mahalliy elektr xavfsizligi talablari asosida amalga oshirilishi kerak.
  • O’rnatish va texnik xizmat ko’rsatish malakali o’rta kuchlanishli elektr mutaxassislari tomonidan amalga oshirilishi kerak.

Buyurtma ma’lumotlari

Buyurtma berish yoki taklif so’rashda quyidagi ma’lumotlarni taqdim eting:

  • Mahsulot modeli: LDC-10, LDCD-10, LDCQ-10, LDCQD-10, LMC-10 yoki LMCD-10
  • Tizim kuchlanishi: 10 kV, 11 kV yoki 12 kV
  • Nominal birlamchi tok / tok transformatsiya nisbati
  • Nominal ikkilamchi tok: 1 A yoki 5 A
  • Har bir ikkilamchi yadro uchun aniqlik klassi va nominal chiqish talablari
  • 10P chiqishi kerak bo’lsa, himoya klassi talablari
  • Devor orqali konstruksiya, magistral o’lchami yoki kommutatsion apparatlar interfeysi talablari
  • Izolyatsiya darajasi va qo’llaniladigan IEC standarti
  • Kommutatsion apparatlar turi, o’rnatish tartibi, terminal yo’nalishi va kerakli tashqi chizma
  • Miqdori, yorliqlar, sertifikatlar, muntazam sinov hisobotlari va qadoqlash talablari

Tanlov maslahatlari

  1. Konstruksiya turini tasdiqlang: Devor orqali o’lchash va himoya dasturlari uchun LDC / LDCD / LDCQ / LDCQD ni, yuqori birlamchi tokli magistral turdagi dasturlar uchun LMC / LMCD ni tanlang.
  2. Kuchlanish sinfini tasdiqlang: 10 kV, 11 kV va 12 kV tizimlari uchun IEC uslubidagi 12/42/75 kV izolyatsiya muvofiqlik darajasidan foydalaning.
  3. Birlamchi tokni tasdiqlang: Tok nisbatini liniya yuklamasi, magistral toki, hisob-kitob diapazoni va himoya sozlamalari diapazoniga qarab tanlang.
  4. Ikkilamchi tokni tasdiqlang: Hisob-kitob qurilmalari, releylar, sim uzunligi va yuk hisob-kitobi asosida 5 A yoki 1 A ni tanlang.
  5. Yadro funksiyasini aniqlang: Har bir ikkilamchi yadro hisob-kitob, signal namunasi olish, releli himoya yoki differensial himoya uchun ishlatilishini ko’rsating.
  6. Nominal yukni tekshiring: Hisob-kitob qurilmalari, releylar va ikkilamchi simlarning umumiy yuklanishi har bir ikkilamchi yadro nominal chiqishidan oshmasligi kerak.
  7. Chizmalarni tasdiqlang: Ishlab chiqarishdan oldin tashqi o’lchamlar, devor orqali interfeys, terminal yo’nalishi va kommutatsion apparatlar zazoralashini tekshiring.

Tez-tez so’raladigan savollar

U ichki 10 kV, 11 kV va 12 kV o’rta kuchlanishli elektr uskunalari uchun tokni o’lchash, elektr energiyasini hisoblash, signal namunasi olish, releli himoya va mikrokomp’yuter himoyasi maqsadlarida ishlatiladi.

LDC variantlari odatda devor orqali o’lchash va himoya dasturlari uchun ishlatiladi, LMC variantlari esa 2000 A dan 5000 A gacha liniyalarda yuqori birlamchi tokli magistral turdagi konstruksiyalardir.

D versiyasi differensial himoya yoki himoyaga yo’naltirilgan konfiguratsiyani bildiradi. Himoya sxemasi himoya uchun maxsus ikkilamchi chiqish yoki differensial tok signali talab qilganda ishlatiladi.

Ha. Xalqaro loyihalar uchun u 10 kV, 11 kV va 12 kV ichki dasturlar uchun odatda 12/42/75 kV bo’lgan 12 kV sinfli izolyatsiya muvofiqlik darajasi bilan belgilanishi mumkin.

Nominal ikkilamchi tok odatda 5 A. Loyiha talablariga qarab 1 A ikkilamchi chiqish yetkazib berilishi mumkin va bu nominal yuk hamda aniqlik klassi bilan birgalikda tasdiqlanishi kerak.

Ha. Standart tok nisbatlari mavjud va loyiha talablariga qarab maxsus birlamchi tok nisbatlari, ikkilamchi tok, nominal chiqish, himoya klassi va terminal tartiblari yetkazib berilishi mumkin.