LZZBW-15, LZZBW-24 Tashqi Epoxy Smola Quvvatli Tok Transformatori

LZZBW-15, LZZBW-24 Tashqi Epoxy Smola Quvvatli Tok Transformatori

15 kV, 17,5 kV va 24 kV taqsimlash tizimlari uchun tashqi qurilishli quruq turdagi epoksidli tok transformatori

  • O'rta kuchlanishli hisoblash uchun moydan xoli, tashqi qurilishli epoksidli quyishli tok transformatori
  • 15 kV / 17,5 kV tizimlar uchun LZZBW-15 va 24 kV tizimlar uchun LZZBW-24
  • Tashqi muhitda ishlatish uchun to'liq yopiq ustun turidagi konstruksiya
  • Hisoblash va himoya sinflari bilan birlashtirilgan 5 A yoki 1 A ikkilamchi chiqish
  • Ikkilamchi kabel ulanishini xavfsizroq amalga oshirish uchun old tomonda terminal qutisi
  • Barqaror o'rnatish uchun yerlov boltlari va pastki qismida to'rtta mahkamlash teshigi

Mahsulotga umumiy ko’rib chiqish

LZZBW-15 / LZZBW-24 tashqi epoksi smola quyilgan tok transformatori — bu 15 kV, 17,5 kV va 24 kV o’rta kuchlanishli taqsimlash tizimlari uchun mo’ljallangan ustun turidagi quruq tok transformatoridir. U 50 Hz yoki 60 Hz nominal chastotali o’zgaruvchan tok tizimlarida tashqi muhitda tokni o’lchash, energiya hisobini yuritish va releli himoya qilish uchun ishlatiladi. Mahsulot epoksi smolani vakuumda quyish texnologiyasi bilan ishlab chiqariladi, bu esa tok transformatoriga tashqi namlik, ultrabinafsha nurlanish va ifloslangan xizmat ko’rsatish sharoitlariga mos keladigan to’liq yopiq izolyatsiya tanasini beradi.

Ushbu seriyani yog’li suvli tok transformatorlarining tashqi quruq alternativasi sifatida pozitsionlashtirish kerak. Tashqi yog’li transformatorlarga qaraganda LZZBW seriyasida transformator yog’i yo’q, sizish xavfi kamroq va maydondagi texnik xizmat ko’rsatish osonroq. Oldingi terminal qutisi xavfsizroq ikkilamchi kabel ulanishi uchun sim chiqish teshigiga ega, pastki plita esa barqaror tashqi o’rnatish uchun yerlov boltlari va to’rtta mahkamlash teshigiga ega.

Mahsulot turi

LZZBW-15, LZZBW-24 Tashqi Epoksi Smola Quyilgan Tok Transformatori Mahsulot Namoyishi

未标题 1

Element LZZBW-15 LZZBW-24
Mahsulot nomi Tashqi epoksi smola quyilgan tok transformatori Tashqi epoksi smola quyilgan tok transformatori
O’rnatish Tashqi Tashqi
Tuzilma Ustun turidagi, to’liq yopiq Ustun turidagi, to’liq yopiq
Izolyatsiya vositasi Tashqi darajali epoksi smola Tashqi darajali epoksi smola
Nominal kuchlanish sinfi 15 kV / 17,5 kV sinfi 24 kV sinfi
Nominal izolyatsiya darajasi 17,5/38/75 kV yoki loyiha talabiga ko’ra 17,5/55/105 kV 24/65/125 kV
Nominal chastota 50 Hz yoki 60 Hz 50 Hz yoki 60 Hz
Nominal ikkilamchi tok 5 A yoki 1 A 5 A yoki 1 A
Odatiy foydalanish Tashqi hisob-kitob, o’lchash va himoya Tashqi hisob-kitob, o’lchash va himoya

Model izohi

LZZBW 15 17.5 24 outdoor current transformer modle type

  • L: Tok transformatori.
  • Z: Ustun turidagi tuzilma.
  • Z: Epoksi smola quyilgan izolyatsiya.
  • B: Himoya g’altakli / hisob-kitob va himoya CT seriyasi.
  • W: Tashqi tur.
  • 15: 15 kV / 17,5 kV sinfidagi tashqi taqsimlash tizimi.
  • 24: 24 kV sinfidagi tashqi taqsimlash tizimi.
  • 5A yoki 1A: Nominal ikkilamchi tok varianti.
  • Aniqlik kombinatsiyasi: 0,2/10P10, 0,5/10P10, 0,2/10P15, 0,5/10P15, 0,2S/5P10 va tegishli loyiha-ga xos kombinatsiyalar kabi hisob-kitob va himoya kombinatsiyalari.

Mahsulotni pozitsionlashtirish

LZZBW seriyasini quruq turdagi taqsimlash hisob-kitobi va himoyasi uchun tashqi epoksi quyilgan tok transformatori sifatida ta’riflash eng yaxshi. Bu ichki kommutatsiya qurilmasi CT emas va yog’li suvli transformator ham emas. Uning asosiy qiymati tashqi quruq izolyatsiya, to’liq yopiq epoksi korpusi, xavfsizroq ikkilamchi sim tortish kirish joyi va ochiq taqsimlash o’rnatmalarida soddalashtirilgan texnik xizmat ko’rsatishdir.

Pozitsionlashtirish nuqtasi Texnik ma’nosi Veb-sayt ifodasi
Tashqi quruq turdagi dizayn Transformator yog’i yo’q, epoksi smola izolyatsiyasi Yog’siz taqsimlash hisob-kitobi uchun tashqi epoksi quyilgan tok transformatori
Ko’p kuchlanishli platforma 15 kV / 17,5 kV va 24 kV versiyalari Turli o’rta kuchlanishli tarmoqlar uchun bitta mahsulot oilasi
Himoya + hisob-kitob Hisob-kitob aniqligi va himoya aniqligini birlashtirish mumkin O’lchash, energiya hisobini yuritish va releli himoya uchun mos keladi
Tashqi terminal qutisi Oldingi chiqish teshigi ikkilamchi kabel sim tortishini qo’llab-quvvatlaydi Xavfsizroq maydon sim tortishi va texnik xizmat ko’rsatishga oson kirish
Pastki mahkamlash tuzilmasi Yerlov boltlari va to’rtta mahkamlash teshigi Braketlarda, platformalarda yoki transformator stansiyasi tuzilmalarida barqaror tashqi o’rnatish

Qo’llash sohalari

  • 15 kV, 17,5 kV va 24 kV tashqi o’rta kuchlanishli taqsimlash tizimlari
  • Tashqi liniya hisob-kitobi va kommunal energiya o’lchovi
  • Ustunga o’rnatilgan hisob-kitob uskunalari va tashqi taqsimlash shkafchalari
  • Tashqi transformator stansiyalari va ixcham transformator stansiyasining kiruvchi / chiquvchi liniyalari
  • Taqsimlash liniyalari va transformatorlar uchun releli himoya zanjirlari
  • Sanoat tashqi elektr taqsimlashi va qayta tiklanadigan energiya tarmoqqa ulanish nuqtalari
  • Tashqi yog’siz o’lchov transformatorlarini talab qiluvchi loyihalar

Xususiyatlari

  • Tashqi epoksi vakuum quyish: To’liq yopiq epoksi smola izolyatsiyasi tashqi dielektrik xususiyatlar va mexanik mustahkamlikni qo’llab-quvvatlaydi.
  • Yog’siz quruq turdagi tuzilma: Yog’li suvli tok transformatorlariga qaraganda yog’ sizish xavfini kamaytiradi va maydondagi texnik xizmat ko’rsatishni soddalashtiradi.
  • Ko’p kuchlanish qamrovi: LZZBW-15 15 kV / 17,5 kV sinfidagi tizimlarni, LZZBW-24 esa 24 kV sinfidagi tizimlarni qamrab oladi.
  • Hisob-kitob va himoya variantlari: Aniqlik kombinatsiyalari joriy o’lchash, daromad hisob-kitobi va releli himoyani qo’llab-quvvatlay oladi.
  • Xavfsiz sim tortish dizayni: Terminal qutisi oldingi chiqish teshigi kabel chiqishiga mos keladi, bu esa xavfsizroq va ishonchliroq ikkilamchi sim tortish imkonini beradi.
  • Barqaror tashqi mahkamlash: Yerlov boltlari va pastki tomonda to’rtta mahkamlash teshigi tashqi tuzilmalarga mustahkam o’rnatishni qo’llab-quvvatlaydi.

Ish prinsipi

LZZBW tashqi tok transformatori o’rta kuchlanishli birlamchi tokni standartlashtirilgan ikkilamchi tok signaliga aylantiradi, odatda 5 A yoki 1 A. Ikkilamchi signal o’lchov asboblari, himoya relelari va monitoring qurilmalariga beriladi. Epoksi smola quyilgan korpus yuqori kuchlanishli birlamchi zanjir va past kuchlanishli ikkilamchi zanjir o’rtasida elektr izolyatsiyasini ta’minlaydi.

Hisob-kitob uchun foydalanishda tok transformatori tanlangan aniqlik sinfi va nominal yuklama doirasida nisbat aniqligi va fazaviy siljishni saqlashi kerak. Himoya uchun foydalanishda himoya g’altagi nosozlik tok sharoitlarida ishonchli chiqish berishi kerak. Shuning uchun buyurtma berishdan oldin tok nisbati, ikkilamchi tok, nominal chiqish, aniqlik sinfi va qisqa muddatli chidamli tok birgalikda tasdiqlanishi kerak.

Texnik ma’lumotlar

Parametr LZZBW-15 LZZBW-24
Mahsulot turi Tashqi epoksi smola quyilgan tok transformatori Tashqi epoksi smola quyilgan tok transformatori
Nominal kuchlanish sinfi 15 kV / 17,5 kV sinfi 24 kV sinfi
Nominal izolyatsiya darajasi 17,5/38/75 kV yoki loyiha talabiga ko’ra 17,5/55/105 kV 24/65/125 kV
Nominal chastota 50 Hz yoki 60 Hz 50 Hz yoki 60 Hz
Nominal birlamchi tok 5 A–600 A havola diapazoni; sozlanadigan 10 A–2000 A havola diapazoni; sozlanadigan
Nominal ikkilamchi tok 5 A yoki 1 A 5 A yoki 1 A
Aniqlik sinfi kombinatsiyasi 0,2/10P10, 0,5/10P10, 0,2/10P15, 0,5/10P15 0,2S/0,5/5P10, 0,2S/0,5/5P20, 0,2S/0,5/5P30 va loyiha-ga xos kombinatsiyalar
Nominal chiqish 10/15 VA yoki 15/15 VA havola 20/20/100, 20/20/60, 20/20/40, 20/20/25, 30/30/120 va tegishli kombinatsiyalar
Quvvat koeffitsienti cosφ = 0,8 orqaga siljish havolasi cosφ = 0,8 orqaga siljish havolasi
Tuzilma turi Ustun turidagi, to’liq yopiq Ustun turidagi, to’liq yopiq
Korpus materiali Tashqi darajali epoksi smola, UV-barqaror va iz qoldirmaydigan Tashqi darajali epoksi smola, UV-barqaror va iz qoldirmaydigan
Atrof-muhit harorati -25°C dan +40°C gacha havola -25°C dan +40°C gacha havola
O’rnatish Tashqi Tashqi
Qo’llaniladigan standartlar IEC 61869-1, IEC 61869-2, GB/T 20840.1, GB/T 20840.2 IEC 61869-1, IEC 61869-2, GB/T 20840.1, GB/T 20840.2

Tanlov jadvali

Quyidagi tanlov jadvali veb-sayt namoyishi uchun tashkil etilgan. Uzoq sarlavhalar va aniqlik sinfi kataklari mahsulot sahifalarida tartib buzilmasligi uchun bir necha qatorga bo’lingan.

Model Nominal Birlamchi
Tok (A)
Aniqlik Sinfi
Kombinatsiyasi
Nominal Chiqish
(VA)
Nominal Qisqa Muddatli
Issiqlik Toki
Nominal Dinamik
Tok
LZZBW-15 5–600 0.2/10P10
0.5/10P10
0.2/10P15
0.5/10P15
10/15VA
15/15VA
Joriy nisbat va loyiha talabi bo’yicha Joriy nisbat va loyiha talabi bo’yicha
Sozlanadigan diapazon Hisob-kitob + himoya kombinatsiyalari Kelishuv bo’yicha Kelishuv bo’yicha Kelishuv bo’yicha
LZZBW-24 10–40 0.2S/0.5/5P10
0.2S/0.5/5P15
0.2S/0.5/5P20
0.2S/0.5/5P30
0.2S/0.5/5P10/5P10
0.2S/0.5/5P15/5P15
0.2S/0.5/5P20/5P20
0.2S/0.5/5P30/5P30
20/20/100
20/20/60
150 × I1n 375 × I1n
50–100 20/20/60
20/20/40
200 × I1n 500 × I1n
150–250 20/20/25 32kA 80kA
300–400 20/20/40
20/20/30/30
50kA 125kA
500–600 20/20/20
20/20/10/10
63kA 160kA
750–800 30/30/120
30/30/80
80kA 200kA
1000–2000 30/30/50/50
30/30/30/30
30/30/25/25
30/30/15/15
100kA 250kA

Eslatma: Jadval dastlabki tanlov uchun. Yakuniy tok nisbati, nominal yuklama, aniqlik sinfi, himoya sinfi, qisqa muddatli issiqlik toki, dinamik tok va terminal tartibi nomplata, tasdiqlangan chizma va zavod sinov hisobotiga ko’ra tasdiqlanishi kerak.

Oddiy ishlash sharoitlari

Parametr Qiymat
O’rnatish joyi Tashqi
Maksimal atrof-muhit harorati +40°C havola
Minimal atrof-muhit harorati -25°C havola
Kunlik o’rtacha harorat ≤ +30°C havola
Dengiz sathidan balandlik Standart xizmat ko’rsatish sharoitlarida ≤ 1000 m; yuqori balandlik kelishuv bo’yicha
Atmosfera sharoiti Loyihaviy chegaralardan tashqari kuchli ifloslanish, korroziyaga sababchi gaz yoki portlovchi atmosfera yo’q
Tashqi ta’sir UV, namlik va iz qoldirmaydigan tashqi izolyatsiya dasturlari uchun mos keladi

O’rnatish va o’lchamlar

LZZBW-15, LZZBW-24 Tashqi Epoksi Smola Quyilgan Tok Transformatori O'rnatish va O'lchamlar

LZZBW seriyasi barqaror mahkamlash plastinkasi, braket, ustunga o’rnatilgan tayanch yoki transformator stansiyasi tuzilmasiga tashqi muhitda o’rnatiladi. Pastki plitada mexanik mahkamlash uchun to’rtta mahkamlash teshigi va xavfsiz yerlov uchun yerlov boltlari mavjud. Terminal qutisi oldingi teshigi ikkilamchi kabel chiqishi bilan moslashtirilishi kerak, bu esa ikkilamchi sim tortishning xavfsiz va ishonchli kirishini ta’minlaydi.

O’rnatish elementi Tavsiya etilgan tekshirish nuqtasi
Mahkamlash poydevori O’rnatishdan oldin to’rtta mahkamlash teshigini, poydevor o’lchamlarini va tayanch mustahkamligini tasdiqlang.
Birlamchi terminal P1 / P2 yo’nalishini, o’tkazgich ulanish usulini va elektr zazorkasini tekshiring.
Ikkilamchi terminal qutisi Sim tortish chiqish teshigini ikkilamchi kabel yo’nalishi bilan moslashtiring va kabel kirishini yaxshi seal qiling.
Yerlov Pastki plitadagi yerlov boltlaridan foydalaning va tok transformatori poydevorini stansiya yerlov tizimiga ulang.
Tashqi izolyatsiya Iz tortish masofasi, ifloslanish darajasi, UV ta’siri va iz qoldirmaydigan talablarni tasdiqlang.
Texnik xizmat ko’rsatish kirish joyi Terminalni tekshirish, nomplatani o’qish va kabel texnik xizmat ko’rsatish uchun joy ajrating.

G’altaklar va terminal belgilari

Birlamchi terminallar odatda P1 va P2 deb belgilanadi. Ikkilamchi terminallar ikkilamchi g’altaklar soni va tasdiqlangan sim tortish sxemasiga ko’ra belgilanadi. Hisob-kitob va himoya konfiguratsiyalari uchun har bir ikkilamchi guruh ishlab chiqarishdan oldin aniq vazifaga tayinlanishi kerak.

Terminal Funksiya Qo’llash eslatmasi
P1 / P2 Birlamchi terminallar Birlamchi tok yo’nalishi va polyarlikka havola sifatida ishlatiladi.
1S1 / 1S2 Birinchi ikkilamchi g’altak Odatda hisob-kitob yoki tok o’lchashga tayinlanadi.
2S1 / 2S2 Ikkinchi ikkilamchi g’altak Odatda releli himoyaga tayinlanadi.
3S1 / 3S2 Belgilangan holda qo’shimcha ikkilamchi g’altak Zaxira himoyasi yoki mustaqil monitoring zanjiri uchun ishlatiladi.
Yerlov nuqtasi Ikkilamchi / poydevor yerlov havolasi Ikkilamchi zanjirning bitta nuqtasi va tok transformatori poydevori loyiha amaliyotiga ko’ra yerlovga ulanishi kerak.

Standartlar va moslik

Yangi xalqaro hujjatlarda LZZBW-15 / LZZBW-24 seriyasi IEC 61869-1 va IEC 61869-2 ga muvofiq ko’rsatilishi kerak. Xitoy standarti hujjatlari uchun GB/T 20840.1 va GB/T 20840.2 dan foydalanish mumkin. IEC 60044-1 kabi eski katalog havolalari tender yoki solishtirish hujjati talab qilganda saqlanishi mumkin.

Xavfsizlik eslatmalari

  • O’rnatishdan oldin kuchlanish sinfi, izolyatsiya darajasi, tok nisbati, nominal ikkilamchi tok, aniqlik sinfi va nominal chiqishni tasdiqlang.
  • O’lchov asboblari yoki himoya relelarini ulashdan oldin P1 / P2 polyarligini va ikkilamchi terminal belgilarini tekshiring.
  • Loyiha yerlov dizayniga ko’ra tok transformatori poydevorini va ikkilamchi zanjirning bitta nuqtasini yerlovga ulang.
  • Birlamchi tok oqayotganda tok transformatori ikkilamchi zanjiri ochiq zanjir bo’lishi mumkin emas.
  • O’lchov asboblari, relelar yoki sinov uskunasini uzishdan oldin ikkilamchi zanjirni tasdiqlangan qisqarish qurilmasi bilan qisqartiring.
  • Ikkilamchi sim tortishdan keyin terminal qutisi kabel chiqishini namlik kirishini oldini olish uchun seal qiling.
  • Mahsulot loyihaviy chegaralaridan tashqari kuchli kimyoviy korroziya, portlovchi gaz yoki mexanik zarba bo’lgan muhitga tok transformatorini o’rnatmang.
  • O’rnatish va ishga tushirish malakali o’rta kuchlanishli elektr mutaxassislari tomonidan amalga oshirilishi kerak.

Tanlov qo’llanmasi

  1. Kuchlanish darajasini tasdiqlang: 15 kV / 17,5 kV tizimlari uchun LZZBW-15, 24 kV tizimlari uchun LZZBW-24 dan foydalaning.
  2. Tashqi quruq turdagi talabni tasdiqlang: Texnik xizmat ko’rsatish yoki atrof-muhit sabablariga ko’ra yog’siz tashqi tok transformatorini afzal ko’rgan joylarda ushbu seriyani tanlang.
  3. Tok nisbatini tanlang: Liniya yuklamasiga, hisob-kitob diapazoniga va himoya sozlamalariga ko’ra birlamchi tokni tanlang.
  4. Ikkilamchi tokni tanlang: An’anaviy o’lchov asboblari va relelar uchun 5 A dan foydalaning; uzun ikkilamchi sim tortish yoki pastroq kabel yuklamasi talab qilinganda 1 A dan foydalaning.
  5. Aniqlik kombinatsiyasini belgilang: Yuqori darajadagi hisob-kitob aniqligi uchun 0,2S / 0,2, releli himoya uchun 5P / 10P dan foydalaning.
  6. Nominal yuklamani tekshiring: O’lchov asboblari, relelar, terminal bloklari va ikkilamchi kabelning umumiy yuklamasini hisoblang.
  7. O’rnatish tafsilotlarini tasdiqlang: Ishlab chiqarishdan oldin poydevor mahkamlash teshiklari, yerlov boltlari, terminal qutisi chiqish yo’nalishi va sim tortish sxemasini tasdiqlang.

Tez-tez so’raladigan savollar

Bu o’rta kuchlanishli taqsimlash hisob-kitobi, tok o’lchash va releli himoya uchun tashqi quruq turdagi epoksi quyilgan tok transformatoridir. LZZBW-15 15 kV / 17,5 kV sinfidagi tizimlar uchun, LZZBW-24 esa 24 kV sinfidagi tizimlar uchun mo’ljallangan.

LZZBW seriyasi transformator yog’i o’rniga epoksi smola quyishdan foydalanadi. U yog’siz, to’liq yopiq va yog’ sizish xavfini oldini olish kerak bo’lgan ko’plab tashqi taqsimlash dasturlarida texnik xizmat ko’rsatishni osonlashtiradi.

Umumiy ikkilamchi tok 5 A. Loyiha pastroq ikkilamchi kabel yuklamasi yoki aniq hisob-kitob va rele qurilmalari bilan moslikni talab qilganda 1 A ikkilamchi chiqish ham tanlanishi mumkin.

Odatiy kombinatsiyalar 0,2S, 0,2, 0,5S va 0,5 kabi hisob-kitob sinflari hamda 5P10, 5P20, 10P10 yoki 10P15 kabi himoya sinflarini o’z ichiga oladi. Yakuniy tanlov yuklama va himoya talabiga bog’liq.

Mahkamlash teshiklari tartibini, tayanch mustahkamligini, P1/P2 yo’nalishini, terminal qutisi chiqishini, ikkilamchi kabelni seal qilishni, yerlov boltlarini, iz tortish masofasini, ifloslanish darajasini va kerakli elektr zazorkasini tekshiring.

Birlamchi tok oqayotganda ochiq ikkilamchi zanjir ikkilamchi terminallar orasida xavfli yuqori kuchlanish hosil qilishi mumkin. Bu izolyatsiyani shikastlab, xavfsizlik xavfini yaratadi. O’lchov asboblari yoki relelarni uzishdan oldin ikkilamchi zanjir qisqartirilishi kerak.

Iltimos, model, kuchlanish sinfi, tok nisbati, 5 A yoki 1 A ikkilamchi chiqish, aniqlik sinfi, nominal yuklama, tashqi xizmat ko’rsatish sharoiti, mahkamlash chizmasi, terminal sxemasi, sinov hisoboti va sertifikat talablari haqida ma’lumot bering.